{"title":"Victron Electrical","description":"\u003cp\u003eVictron electrical accessories cover the wiring, protection, and interface components needed to complete a professional installation. This includes fuse holders, MEGA fuses, busbars, cable lugs, VE.Direct cables, VE.Bus cables, MK3-USB interfaces, and other system components that connect Victron devices together and to your wider electrical installation. Correct cable sizing, fusing, and earthing are essential for safe operation. If you are unsure which accessories your system requires, our technical team can advise before you order.\u003c\/p\u003e","products":[{"product_id":"victron-mega-fuse-60a-80v-pack-of-5","title":"Victron MEGA-fuse 60A\/80V (package of 5 pcs) - CIP138060020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 60A\/80V (Pack of 5) — CIP138060020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 60A\/80V is a high-current blade-style fuse designed for DC protection in battery systems, inverters and other high-current 12V, 24V and 48V applications. Sold in a pack of five, this fuse is a direct fit for Victron MEGA fuseholders and compatible third-party holders of the same format.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e60A continuous current rating suitable for high-current DC circuits.\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating covers 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA blade format for use with standard MEGA fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, providing spares for commissioning, servicing and ongoing maintenance.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 45g per pack, easy to carry as part of an installer toolkit.\u003c\/li\u003e\n  \u003cli\u003eVictron SKU CIP138060020 with GTIN 8719076061649 for straightforward reordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses are a widely used protection format in DC power systems. The blade-style body allows fast visual inspection of fuse condition and straightforward replacement without specialist tools. At 60A and 80V DC, this fuse is appropriate for protecting battery cables, inverter feeds and DC distribution circuits where overcurrent protection is required between the battery bank and downstream equipment.\u003c\/p\u003e\n\n\u003cp\u003eThe 80V DC rating is important in battery applications because DC arc energy is significantly higher than in equivalent AC circuits. A fuse rated only for AC or for lower DC voltages may not interrupt a fault current safely in a 48V lithium or lead-acid system. Always confirm that the fuse voltage rating meets or exceeds the maximum open-circuit voltage of the battery bank it is protecting.\u003c\/p\u003e\n\n\u003cp\u003eBuying in a pack of five makes practical sense for installers working across multiple systems or commissioning larger battery arrays, where having replacement fuses on site avoids delays.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP138060020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 60A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse format: MEGA blade\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.045 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061649\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on battery cables in 12V, 24V and 48V DC systems.\u003c\/li\u003e\n  \u003cli\u003eInverter and inverter\/charger feed protection in off-grid and marine installations.\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards and busbar protection in motorhome, caravan and boat builds.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing Victron MEGA fuseholder installations.\u003c\/li\u003e\n  \u003cli\u003eSpare stock for solar installers and system integrators servicing battery-based systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 60A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses must be installed in a compatible MEGA fuseholder rated for the circuit voltage and current. Ensure the fuseholder is securely mounted and that cable terminations are correctly torqued to prevent resistance heating at the connection. DC battery circuits carry high fault currents and should be installed by a qualified electrician or experienced system integrator. Always isolate the battery before replacing a fuse. Do not substitute a higher-rated fuse to resolve a repeated blowing fault — investigate the underlying cause first.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435078631758,"sku":"CIP138060020","price":28.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/mega-fuse-60a32v-package-of-5-pcs-cip136060010-397618.jpg?v=1747950279"},{"product_id":"victron-mega-fuse-100a-80v-pack-of-5","title":"Victron MEGA-fuse 100A\/80V (package of 5 pcs) - CIP138100020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 100A\/80V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 100A\/80V is a high-current blade fuse designed for DC circuit protection in battery systems, inverters and other high-current 12V, 24V and 48V applications. Supplied in a pack of five, it is suited to installers and system builders who need reliable overcurrent protection on DC busbars and cable runs.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100A continuous current rating for high-current DC protection.\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating, compatible with 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA blade fuse format, compatible with standard MEGA fuseholders.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a pack of 5, reducing per-unit cost for multi-circuit or multi-system installations.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 45g per pack, easy to carry as service stock.\u003c\/li\u003e\n  \u003cli\u003eSKU CIP138100020, GTIN 8719076061663 for straightforward ordering and inventory management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a widely used format in DC electrical systems, particularly where high continuous currents must be protected at relatively low voltages. The 80V DC rating covers the full range of common battery bank voltages, including 48V nominal systems which can reach higher voltages during charging. At 100A, this fuse is appropriate for protecting main battery cables, inverter feeds and DC distribution connections where the circuit design calls for that current threshold.\u003c\/p\u003e\n\n\u003cp\u003eThe MEGA format uses a bolted or clamped fuseholder rather than a push-in blade, which provides a more secure connection under vibration and thermal cycling. This makes it a practical choice for marine, vehicle and off-grid installations where connections are subject to movement. Victron Energy produces these fuses to complement their range of MEGA fuseholders, ensuring dimensional and electrical compatibility across their DC protection product line.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCurrent rating: 100A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 45g (per pack)\u003c\/li\u003e\n  \u003cli\u003eSKU: CIP138100020\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061663\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain battery cable protection in 12V, 24V and 48V off-grid systems.\u003c\/li\u003e\n  \u003cli\u003eInverter and inverter\/charger DC input protection.\u003c\/li\u003e\n  \u003cli\u003eDC busbar and distribution board overcurrent protection.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome electrical systems requiring MEGA-format fusing.\u003c\/li\u003e\n  \u003cli\u003eBattery-to-battery charger and DC-DC converter circuit protection.\u003c\/li\u003e\n  \u003cli\u003eService stock for installers maintaining multiple Victron-based systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 100A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses must be installed in a compatible MEGA fuseholder rated for the intended current and voltage. Ensure the fuseholder and all associated cabling are correctly rated for 100A continuous DC current before installation. DC electrical work on battery systems carries risk of arc flash and short-circuit injury. Installation should be carried out by a qualified electrician or competent person familiar with DC system design. For systems connected to a solar PV array or grid-tied inverter, ensure all relevant UK wiring regulations and G98\/G99 requirements are observed by a suitably qualified installer.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435082301774,"sku":"CIP138100020","price":28.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/mega-fuse-100a32v-package-of-5-pcs-cip136100010-797208.jpg?v=1747934599"},{"product_id":"victron-mega-fuse-150a-80v-pack-of-5","title":"Victron MEGA-fuse 150A\/80V (package of 5 pcs) - CIP138150020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 150A\/80V (Pack of 5) — CIP138150020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MEGA-fuse 150A\/80V is a high-current blade-style fuse designed for DC protection in battery systems, inverters, and solar installations. Sold in a pack of five, it is suited to professional installers who need reliable overcurrent protection for cables and equipment operating at up to 80V DC.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e150A continuous current rating for high-load DC circuits.\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating, compatible with 12V, 24V, 48V and higher-voltage battery systems up to 80V.\u003c\/li\u003e\n  \u003cli\u003eMEGA blade-fuse format, compatible with standard MEGA fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eProvides overcurrent and short-circuit protection for inverters, battery banks, and DC distribution.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, practical for installation projects requiring multiple protection points or spares on site.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 45g per pack, easy to carry and store on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses are a widely used format in DC electrical systems, particularly in marine, off-grid, and vehicle applications where high currents must be safely interrupted in the event of a fault. The 150A rating makes this fuse appropriate for protecting cables and equipment connected to large battery banks or inverter inputs, where fault currents can be extremely high and must be cleared quickly to prevent fire or equipment damage.\u003c\/p\u003e\n\n\u003cp\u003eThe 80V DC rating means this fuse is suitable for use across the common battery voltages found in solar and off-grid systems: 12V, 24V, and 48V nominal systems all fall well within this limit. It is not rated for AC circuits. The MEGA format is a bolt-down blade fuse, which provides a secure, low-resistance connection compared to push-in fuse types, making it appropriate for permanent installations subject to vibration or high current cycling.\u003c\/p\u003e\n\n\u003cp\u003ePurchasing in a pack of five is practical for installers fitting multiple circuits or systems, and ensures spares are available without needing to reorder for routine maintenance.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP138150020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 150A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse format: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.045 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061687\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on inverter DC input cables in 12V, 24V, and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eBattery bank protection in off-grid solar installations.\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards and busbar protection in marine and motorhome electrical systems.\u003c\/li\u003e\n  \u003cli\u003eProtection of high-current DC wiring in commercial vehicle and fleet conversions.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MEGA fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron MEGA-fuse 150A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses must be installed in a compatible MEGA fuseholder rated for the current and voltage of the circuit. Ensure the fuseholder and associated cabling are correctly rated for 150A continuous use. DC fuses are not interchangeable with AC fuses of the same current rating. For inverter and battery installations, a qualified electrician or MCS-accredited installer should carry out the work. Always isolate the battery before replacing or installing fuses.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435105927502,"sku":"CIP138150020","price":27.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/Victron_Energy-CIP138150020.jpg?v=1756820019"},{"product_id":"victron-mega-fuse-200a-80v-pack-5","title":"Victron MEGA-fuse 200A\/80V (package of 5 pcs) - CIP138200020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 200A\/80V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MEGA-fuse 200A\/80V is a high-current blade-style fuse designed for DC protection in battery systems, inverters and other high-current electrical installations. Sold in a pack of five, it is suited to installers and system builders who need reliable overcurrent protection at 200A continuous rating up to 80V DC.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e200A current rating with an 80V DC voltage rating, suitable for 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA blade fuse format, compatible with standard MEGA fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eProvides overcurrent and short-circuit protection for DC wiring between batteries and inverters or charge controllers.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, practical for professional installers stocking spares or completing multiple installations.\u003c\/li\u003e\n  \u003cli\u003eCompact, low-profile design allows installation in tight cable runs and battery enclosures.\u003c\/li\u003e\n  \u003cli\u003eSKU: CIP138200020 | GTIN: 8719076061700 | Weight: 0.045 kg (per pack).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses are a widely used format in automotive and marine DC electrical systems, and are equally at home in solar, off-grid and battery storage installations. The 200A rating makes this fuse appropriate for protecting the main DC feed between a battery bank and a large inverter or inverter\/charger, where fault currents can be extremely high and fast protection is essential.\u003c\/p\u003e\n\n\u003cp\u003eThe 80V DC voltage rating covers all common battery voltages used in residential and light commercial off-grid systems, including 12V, 24V and 48V configurations. It is important to select a fuse with a DC voltage rating that meets or exceeds the system voltage. AC voltage ratings do not apply to DC circuits, and using an under-rated fuse can result in arc faults during interruption. This fuse is rated specifically for DC use.\u003c\/p\u003e\n\n\u003cp\u003eBuying in a pack of five reduces per-unit cost and ensures spares are on hand for commissioning, servicing or future installations. The fuses are compatible with Victron MEGA fuseholders and other standard MEGA-format holders available from electrical wholesalers.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCurrent rating: 200A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse format: MEGA blade\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003ePack weight: 0.045 kg\u003c\/li\u003e\n  \u003cli\u003eSKU: CIP138200020\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061700\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain DC overcurrent protection between battery banks and Victron MultiPlus or Quattro inverter\/chargers.\u003c\/li\u003e\n  \u003cli\u003eProtection of DC cabling in off-grid solar systems with 12V, 24V or 48V battery configurations.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome DC electrical systems requiring high-current fuse protection.\u003c\/li\u003e\n  \u003cli\u003eBattery-to-busbar connections in larger energy storage installations.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MEGA fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron MEGA-fuse 200A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses must be installed in a compatible MEGA fuseholder rated for the system voltage and current. Always isolate the battery before replacing or installing fuses. In battery and inverter installations, DC wiring and overcurrent protection should be sized and installed by a qualified electrician familiar with DC systems. For solar PV and battery storage systems in the UK, installation by an MCS-accredited or suitably qualified installer is recommended. Ensure the fuseholder and associated wiring are rated to at least 200A and 80V DC before fitting these fuses.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435113496910,"sku":"CIP138200020","price":25.19,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron_fuse_80v.jpg?v=1756823570"},{"product_id":"victron-mega-fuse-225a-80v-pack-of-5","title":"Victron MEGA-fuse 225A\/80V (package of 5 pcs) - CIP138225020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 225A\/80V (Pack of 5) — CIP138225020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 225A\/80V is a high-current blade-style fuse designed to protect DC wiring in battery systems, inverters and other high-current 12V, 24V and 48V DC applications. Sold in a pack of five, this fuse is a standard consumable for professional solar and off-grid installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e225A continuous current rating, suitable for high-load DC circuits in battery and inverter systems.\u003c\/li\u003e\n  \u003cli\u003e80V DC maximum voltage rating, compatible with 12V, 24V and 48V battery banks.\u003c\/li\u003e\n  \u003cli\u003eMEGA-fuse format, a widely used standard in automotive and marine DC protection applications.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, providing spares for commissioning, servicing and ongoing maintenance.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 45g per pack, easy to carry as part of an installer's standard kit.\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard MEGA fuseholders, including Victron's own MEGA fuseholder range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a bolt-down blade fuse format commonly used to protect the main DC cables between battery banks and inverters, charge controllers or busbars. At 225A, this fuse is suited to systems where the continuous DC current draw is high, such as large inverter installations or multi-battery configurations. The 80V DC voltage rating covers the full range of standard lead-acid and lithium battery voltages up to 48V nominal.\u003c\/p\u003e\n\n\u003cp\u003eFuse sizing is critical in DC systems. An incorrectly rated fuse either fails to protect the cable under fault conditions or nuisance-trips under normal load. The 225A rating should be selected based on the cable cross-section being protected and the maximum continuous current of the connected equipment. Always refer to the cable manufacturer's current rating and the inverter or charger documentation when specifying fuse size.\u003c\/p\u003e\n\n\u003cp\u003eBuying in a pack of five makes practical sense for installers working across multiple sites or commissioning larger systems where more than one fuse position is required. It also ensures a spare is available on-site during initial commissioning and fault-finding.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP138225020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 225A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 45g (full pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061717\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain DC overcurrent protection between battery banks and inverters or inverter\/chargers.\u003c\/li\u003e\n  \u003cli\u003eProtection of DC cabling in off-grid solar systems with 12V, 24V or 48V battery banks.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome DC electrical systems requiring high-current fuse protection.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MEGA fuseholder installations during servicing or fault rectification.\u003c\/li\u003e\n  \u003cli\u003eMulti-fuse DC distribution boards and busbar protection in commercial off-grid systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 225A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses must be installed in a compatible MEGA fuseholder rated for the voltage and current of the circuit. Ensure the fuseholder and connecting cables are correctly rated for 225A continuous DC current before installation. DC wiring in battery and inverter systems carries significant fault energy and should be installed by a qualified electrician or MCS-accredited installer. Always isolate the battery bank before replacing or inspecting fuses.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435117363534,"sku":"CIP138225020","price":28.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron_fuse_80v.jpg?v=1756823570"},{"product_id":"victron-mega-fuse-250a-80v-pack-5","title":"Victron MEGA-fuse 250A\/80V (package of 5 pcs) - CIP138250020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 250A\/80V — CIP138250020 (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 250A\/80V is a high-current blade-style fuse rated for use in 12V, 24V and 48V DC battery systems. Sold in a pack of five, it is suited to professional installers who need reliable overcurrent protection on high-current DC circuits such as inverter feeds, battery interconnects and busbar connections.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e250A continuous current rating provides overcurrent protection on heavy-duty DC circuits.\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating makes it compatible with 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA blade-fuse format fits standard MEGA fuseholders, including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, practical for installers carrying spares or completing multi-circuit installations.\u003c\/li\u003e\n  \u003cli\u003eCompact, low-profile body keeps installation neat within battery enclosures and distribution boards.\u003c\/li\u003e\n  \u003cli\u003eWeight of 45g per pack confirms a lightweight, space-efficient form factor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses are a widely used format in DC power systems, particularly where high current flows between batteries and inverters or charge controllers. The 250A rating is a common choice for inverter installations in the 2kW to 5kW range on 12V or 24V systems, where cable runs from the battery bank require protection against short-circuit faults. At 80V DC, the fuse is rated well above the maximum operating voltage of a 48V battery system, providing an appropriate safety margin.\u003c\/p\u003e\n\n\u003cp\u003eThe MEGA format uses a bolt-down or clip-in fuseholder rather than a plug-in blade, which makes it more suitable for high-current applications than standard automotive blade fuses. This fuse is designed to be used with a compatible MEGA fuseholder. The fuseholder is sold separately. Always verify that the fuseholder is rated to match or exceed the fuse's current and voltage ratings before installation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP138250020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 250A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse format: MEGA blade\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003ePack weight: 0.045 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061724\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on inverter DC input cables in 12V and 24V off-grid systems.\u003c\/li\u003e\n  \u003cli\u003eBattery bank to busbar connections in marine, motorhome and vehicle installations.\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards in off-grid cabins, narrowboats and remote power systems.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MEGA fuseholder installations.\u003c\/li\u003e\n  \u003cli\u003eMulti-circuit DC systems where several high-current feeds require individual fuse protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 250A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses must be installed in a compatible MEGA fuseholder rated for the circuit voltage and current. Fuses should be positioned as close to the positive battery terminal as practicable to protect the full length of the cable run. DC wiring at these current levels carries significant fault energy, and all connections should be made by a qualified electrician or competent installer familiar with DC battery systems. Ensure cable cross-section is correctly sized for 250A continuous current before selecting this fuse rating.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435118870862,"sku":"CIP138250020","price":24.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/mega_fuse_victron_400Amps_ddc80866-6448-4c06-a54e-429e8f43c16f.webp?v=1774534896"},{"product_id":"victron-mega-fuse-400a-32v-pack-5","title":"Victron MEGA-fuse 400A\/32V (package of 5 pcs) - CIP136400010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 400A\/32V (Pack of 5) — CIP136400010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 400A\/32V is a high-current blade-style fuse rated for 32V DC systems, supplied in a pack of five. It is designed for use in battery protection circuits, inverter installations and other high-current DC applications where reliable overcurrent protection is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e400A current rating suitable for high-current DC battery and inverter circuits.\u003c\/li\u003e\n  \u003cli\u003e32V DC voltage rating, compatible with 12V and 24V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA blade fuse format, compatible with standard MEGA fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a pack of 5, providing spares for commissioning, servicing or multi-circuit installations.\u003c\/li\u003e\n  \u003cli\u003eCompact, low-profile design allows installation in tight cable runs and battery enclosures.\u003c\/li\u003e\n  \u003cli\u003eSKU CIP136400010, GTIN 8719076016663 for straightforward procurement and stock management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses are a widely used format in DC power systems, particularly for protecting the main cable between a battery bank and an inverter or distribution board. At 400A, this fuse is suited to large inverter installations where cable protection at the battery terminal is a regulatory and practical requirement. The 32V rating covers both 12V and 24V nominal battery systems, which are the most common voltages in marine, vehicle and off-grid solar installations.\u003c\/p\u003e\n\n\u003cp\u003eThe MEGA fuse format uses a bolted connection rather than a push-fit blade, which provides a lower-resistance joint and greater mechanical stability under vibration. This makes it appropriate for mobile applications such as motorhomes, boats and commercial vehicles, as well as static off-grid systems. Fuses in this format are consumed items: they should be replaced after any fault event, and having spares on site is standard practice for professional installers.\u003c\/p\u003e\n\n\u003cp\u003eThis fuse is compatible with Victron MEGA fuseholders (sold separately). Always verify that the fuseholder is rated for the current and voltage of the application before installation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP136400010\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 400A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 32V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.05 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076016663\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain battery fuse protection for 12V and 24V inverter installations.\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection on battery-to-busbar connections in off-grid solar systems.\u003c\/li\u003e\n  \u003cli\u003eMarine DC distribution boards and battery protection circuits.\u003c\/li\u003e\n  \u003cli\u003eMotorhome, campervan and commercial vehicle power systems.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MEGA fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 400A\/32V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses must be installed in a compatible MEGA fuseholder rated for the application voltage and current. The fuse should be positioned as close to the battery positive terminal as practicable to provide effective short-circuit protection for the full cable run. Ensure the fuseholder connections are torqued to the manufacturer's specification to avoid resistance heating at the joint. For inverter and battery installations forming part of a solar PV system, installation by a qualified electrician is recommended. Always isolate the battery before replacing a fuse.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435122803022,"sku":"CIP136400010","price":12.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/mega-fuse-400a32v-package-of-5-pcs-cip136400010-492549.jpg?v=1747934669"},{"product_id":"victron-mega-fuse-500a-32v-pack-5","title":"Victron MEGA-fuse 500A\/32V (package of 5 pcs) - CIP136500010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 500A\/32V (Pack of 5) — CIP136500010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 500A\/32V is a high-current blade-style fuse rated for 32V DC systems. Sold in packs of five, it is designed for use in battery protection circuits, inverter installations and other high-current DC applications where reliable overcurrent protection is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e500A current rating suitable for high-current DC battery and inverter circuits.\u003c\/li\u003e\n  \u003cli\u003e32V DC voltage rating, compatible with 12V and 24V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA-fuse format, designed to fit standard MEGA fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, providing spares for commissioning, maintenance or multi-circuit installations.\u003c\/li\u003e\n  \u003cli\u003eCompact, lightweight design at 0.05 kg per pack, easy to store and transport on site.\u003c\/li\u003e\n  \u003cli\u003eProvides short-circuit and overcurrent protection for cables, inverters and battery banks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a widely used format in automotive, marine and solar DC installations. The 500A rating makes this fuse appropriate for large inverter installations, typically those in the 3000W to 5000W range on 12V systems, or higher-capacity 24V systems. The 32V maximum voltage rating covers both 12V and 24V nominal battery banks, including those with elevated charging voltages.\u003c\/p\u003e\n\n\u003cp\u003eThe fuse is installed between the battery positive terminal and the main DC load or inverter input, protecting the wiring and connected equipment in the event of a short circuit or sustained overload. Using the correct fuse rating for the cable cross-section and load is essential. A 500A fuse should be paired with appropriately rated cable, typically 95mm² or larger depending on run length and installation conditions.\u003c\/p\u003e\n\n\u003cp\u003ePurchasing in a pack of five is practical for installers who work across multiple sites or who want to keep a spare on hand after commissioning. MEGA-fuses are consumable components and should be replaced after any fault event, never re-used.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP136500010\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 500A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 32V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.05 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076016670\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection for Victron and third-party inverters on 12V or 24V battery systems.\u003c\/li\u003e\n  \u003cli\u003eBattery bank protection in off-grid solar installations.\u003c\/li\u003e\n  \u003cli\u003eMarine DC systems requiring high-current fuse protection.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome leisure battery circuits with high-draw loads.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MEGA fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x MEGA-fuse 500A\/32V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses must be installed in a compatible MEGA fuseholder rated for the current and voltage in use. The fuse should be positioned as close to the battery positive terminal as practicable to maximise protection of the wiring. Ensure the cable rating matches or exceeds the fuse rating. For inverter and battery installations in solar PV systems, installation by a qualified electrician is recommended. Do not exceed the 32V DC voltage rating of this fuse.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435123753294,"sku":"CIP136500010","price":12.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/mega-fuse-500a32v-package-of-5-pcs-cip136500010-736881.jpg?v=1747934678"},{"product_id":"victron-mega-fuse-250a-58v-48v","title":"Victron MEGA-fuse 250A\/58V-48Vprod(1 pc) *If 0, order CIP138250020* - CIP137250010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 250A\/58V for 48V Systems (1 pc) — CIP137250010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MEGA-Fuse 250A\/58V is a high-current blade-style fuse designed for overcurrent protection in 48V battery systems. It is used in conjunction with a compatible MEGA fuseholder and is suited to DC circuits in solar, off-grid and marine installations where reliable, rated protection is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 250A continuous current with a maximum voltage of 58V DC, making it appropriate for 48V nominal battery banks.\u003c\/li\u003e\n  \u003cli\u003eMEGA-fuse format provides a compact, bolt-down connection suitable for high-current DC applications.\u003c\/li\u003e\n  \u003cli\u003eSingle fuse per pack (1 pc), allowing replacement or single-circuit installation without purchasing unnecessary spares.\u003c\/li\u003e\n  \u003cli\u003eVictron part number CIP137250010, compatible with Victron MEGA fuseholders designed for this fuse format.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 9 grams, with a GTIN of 8719076016700 for straightforward procurement and stock management.\u003c\/li\u003e\n  \u003cli\u003eProvides a sacrificial protection point in DC wiring, helping to protect inverters, battery monitors and other connected equipment from overcurrent damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a standard format for high-current DC protection in battery-based systems. The 250A rating is commonly used on the main DC feed between a 48V battery bank and an inverter or inverter\/charger, where cable runs and equipment ratings demand a clearly defined fault current limit. The 58V maximum voltage rating gives adequate headroom above the typical maximum charge voltage of a 48V lithium or lead-acid battery bank.\u003c\/p\u003e\n\n\u003cp\u003eThis fuse must be installed in a compatible MEGA fuseholder. If the CIP137250010 shows zero stock, Victron recommends ordering CIP138250020 as the alternative. Always verify the fuseholder model is rated for the same voltage and current before installation. The fuse itself is a consumable item and should be replaced like-for-like after any overcurrent event.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP137250010\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 250A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 58V DC (for 48V nominal systems)\u003c\/li\u003e\n  \u003cli\u003eFuse format: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 1 piece\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.009 kg (9 g)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076016700\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain DC overcurrent protection between a 48V battery bank and a Victron MultiPlus or Quattro inverter\/charger.\u003c\/li\u003e\n  \u003cli\u003eFuse replacement in existing MEGA fuseholder installations following an overcurrent event.\u003c\/li\u003e\n  \u003cli\u003eOff-grid solar systems with 48V battery storage requiring a rated DC protection point.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle DC systems operating at 48V nominal voltage.\u003c\/li\u003e\n  \u003cli\u003eAny DC circuit where a MEGA-format fuse at 250A\/58V is specified by the system designer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron MEGA-Fuse 250A\/58V (CIP137250010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis fuse must be fitted in a correctly rated MEGA fuseholder. Ensure the fuseholder is rated for at least 58V DC and 250A before installation. DC wiring at this current level carries significant fault energy and should be installed by a qualified electrician or accredited installer familiar with battery-based DC systems. Always isolate the battery bank before replacing or installing fuses. Do not substitute with a fuse of a higher current rating, as this will defeat the purpose of overcurrent protection.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435135582542,"sku":"CIP137250010","price":23.77,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/mega-fuse-250a58v-for-48v-products-1-pc-cip137250010-618623.jpg?v=1747934721"},{"product_id":"victron-6-way-mega-fuse-holder-cip050060000","title":"Victron Fuse holder 6-way for MEGA-fuse - CIP050060000","description":"\u003ch1 style=\"color: #f87c24;\"\u003e6-Way MEGA Fuse Holder — CIP050060000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 6-way MEGA fuse holder is a dedicated busbar-style fuse distribution block designed to accept up to six MEGA-fuses. It is suited to 12V, 24V and 48V DC systems where multiple circuits need individual overcurrent protection from a single point, such as battery banks, inverter installations and off-grid distribution boards.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAccepts six MEGA-fuses, allowing up to six individually protected DC circuits from one block.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for MEGA-fuse format, ensuring a secure, low-resistance connection at each fuse position.\u003c\/li\u003e\n  \u003cli\u003eCompact, single-unit construction simplifies wiring and reduces the number of individual fuse holders required.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron Energy MEGA-fuse range, maintaining system integrity across Victron installations.\u003c\/li\u003e\n  \u003cli\u003eWeight of 0.53 kg indicates a solid, substantial build suitable for permanent panel or enclosure mounting.\u003c\/li\u003e\n  \u003cli\u003eSuitable for use in battery systems, inverter output distribution, and multi-circuit DC load centres.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a standard format for high-current DC protection, commonly used on the battery terminals of inverters, motor drives and large DC loads. Grouping multiple MEGA-fuse positions into a single 6-way holder keeps installations tidy and makes it straightforward to assign a dedicated fuse to each circuit without running separate holders throughout the enclosure.\u003c\/p\u003e\n\n\u003cp\u003eThe 6-way format is particularly useful in off-grid and marine installations where a battery bank feeds several loads simultaneously. Each circuit, whether it is an inverter, a DC distribution rail, a charger or an auxiliary load, can be individually protected and isolated by removing its fuse without disturbing the rest of the system. This approach also simplifies fault-finding and maintenance.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP050060000\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076051350\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA-fuse\u003c\/li\u003e\n  \u003cli\u003eNumber of fuse positions: 6\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.53 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMulti-circuit DC distribution in off-grid solar systems\u003c\/li\u003e\n  \u003cli\u003eBattery bank protection and circuit distribution in marine and motorhome installations\u003c\/li\u003e\n  \u003cli\u003eInverter and charger installations requiring individual circuit overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eDC load centres in commercial and industrial off-grid systems\u003c\/li\u003e\n  \u003cli\u003eCentralised fuse management in 12V, 24V or 48V battery systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy 6-way MEGA fuse holder (CIP050060000)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are not included and must be sourced separately, sized appropriately for each circuit. Ensure all connections are torqued to the manufacturer's specification to avoid resistance heating at high currents. Installation in high-current DC systems should be carried out by a qualified electrician or accredited installer familiar with battery system wiring. Always disconnect the battery bank before working on fuse holders or busbars.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435317608782,"sku":"CIP050060000","price":22.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/fuse-holder-6-way-for-mega-fuse-cip050060000-159394.jpg?v=1747934783"},{"product_id":"victron-lynx-shunt-cnn-fuse-325a-80v","title":"Victron Fuse CNN 325A\/80V for Lynx shunt (1 pc) - CIP140325000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eFuse CNN 325A\/80V for Victron Lynx Shunt (1 pc)\u003c\/h1\u003e\n\n\u003cp\u003eThis is the OEM replacement CNN fuse rated at 325A and 80V DC, designed specifically for use with the Victron Lynx Shunt. It provides overcurrent protection within the Lynx busbar system and is a direct fit for the Lynx Shunt fuse holder. Suitable for professional installers maintaining or commissioning Victron Lynx-based battery systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 325A continuous current and 80V DC, matched to the Lynx Shunt specification.\u003c\/li\u003e\n  \u003cli\u003eCNN fuse format, designed for direct installation into the Victron Lynx Shunt fuse holder.\u003c\/li\u003e\n  \u003cli\u003eProvides overcurrent protection for the DC busbar and connected battery circuits.\u003c\/li\u003e\n  \u003cli\u003eOEM Victron Energy part, ensuring correct fit and electrical rating without modification.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a single fuse (1 pc), suitable for replacement or commissioning stock.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 58g, compact for storage as a spare on-site or in a service kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Lynx Shunt is a current measurement and fuse module within the Victron Lynx busbar system. The CNN 325A\/80V fuse sits inside the Lynx Shunt and protects the DC circuit from overcurrent events. Using the correct OEM fuse ensures the protection threshold is accurate and that the fuse physically seats correctly in the holder without risk of arcing or poor contact.\u003c\/p\u003e\n\n\u003cp\u003eA blown or degraded fuse in the Lynx Shunt will disable current measurement and interrupt the DC circuit. Keeping a spare on hand is standard practice for any installation using the Lynx Shunt, particularly in off-grid, marine or vehicle systems where access for sourcing parts may be limited. This fuse is the correct replacement part as specified by Victron Energy.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP140325000\u003c\/li\u003e\n  \u003cli\u003eFuse type: CNN\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 325A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eCompatible with: Victron Lynx Shunt\u003c\/li\u003e\n  \u003cli\u003eQuantity: 1 piece\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.058 kg (58g)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076021940\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReplacement fuse for Victron Lynx Shunt installations in off-grid solar systems.\u003c\/li\u003e\n  \u003cli\u003eSpare part stocking for marine and narrowboat DC electrical systems using the Lynx busbar.\u003c\/li\u003e\n  \u003cli\u003eCommissioning and maintenance of vehicle or motorhome battery systems built around the Victron Lynx platform.\u003c\/li\u003e\n  \u003cli\u003eService and repair work on existing Lynx Shunt installations where the fuse has blown or requires scheduled replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x CNN 325A\/80V fuse for Victron Lynx Shunt\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eAlways isolate the DC circuit fully before replacing the fuse in a Lynx Shunt. Work on live DC busbars at these current ratings carries a serious risk of arc flash and injury. This replacement should be carried out by a qualified electrician or experienced installer familiar with DC battery systems. Confirm the fault condition that caused the original fuse to blow before fitting a replacement, as fitting a new fuse into a persisting fault will result in immediate failure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435331862862,"sku":"CIP140325000","price":38.39,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/fuse-cnn-325a80v-for-lynx-shunt-1-pc-cip140325000-853843.jpg?v=1747934817"},{"product_id":"victron-mega-fuse-modular-holder-cip100200100","title":"Victron Modular fuse holder for MEGA-fuse - CIP100200100","description":"\u003ch1 style=\"color: #f87c24;\"\u003eModular Fuse Holder for MEGA-Fuse — CIP100200100\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy modular fuse holder is designed to accept MEGA-fuses in DC battery and power distribution systems. It is suited to professional installers working on off-grid, marine, vehicle and solar battery installations where a reliable, serviceable fuse point is required in the main positive cable run.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAccepts standard MEGA-fuse cartridges, which are widely used in high-current DC protection applications.\u003c\/li\u003e\n  \u003cli\u003eModular design allows multiple holders to be linked together for multi-circuit fuse distribution.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.09 kg, suitable for installations with limited space.\u003c\/li\u003e\n  \u003cli\u003eVictron Energy part number CIP100200100, compatible with the Victron MEGA-fuse range.\u003c\/li\u003e\n  \u003cli\u003eRobust terminal connections suitable for large-section DC cabling used in battery systems.\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076018124, confirming genuine Victron Energy product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a standard format for high-current DC overcurrent protection, commonly rated between 32A and 500A. They are used to protect the main cable between a battery bank and an inverter, charger or busbar. This fuse holder provides the mechanical housing and electrical termination needed to install a MEGA-fuse correctly in a DC circuit.\u003c\/p\u003e\n\n\u003cp\u003eThe modular format is particularly useful in systems with multiple battery strings or parallel inverter connections, where each circuit requires its own fuse point. Holders can be mounted side by side and linked, keeping the installation tidy and making individual fuse replacement straightforward during maintenance.\u003c\/p\u003e\n\n\u003cp\u003eUsing a correctly rated and properly housed fuse at the battery terminal is a fundamental requirement of any DC system. This holder ensures the fuse is accessible, secure and replaceable without disturbing the rest of the wiring.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP100200100\u003c\/li\u003e\n  \u003cli\u003eCompatible fuse type: MEGA-fuse\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.09 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076018124\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Victron Energy\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain battery fuse protection in off-grid solar systems with inverters or inverter\/chargers.\u003c\/li\u003e\n  \u003cli\u003eDC overcurrent protection in narrowboat, canal boat and marine electrical installations.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome leisure battery systems requiring a serviceable fuse point.\u003c\/li\u003e\n  \u003cli\u003eMulti-circuit fuse distribution boards using linked modular holders.\u003c\/li\u003e\n  \u003cli\u003eReplacement or additional fuse holder in existing Victron Energy system installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy modular MEGA-fuse holder (CIP100200100)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis fuse holder should be installed by a qualified electrician or experienced installer familiar with DC battery systems. The fuse holder must be positioned as close to the battery positive terminal as practicable, in line with wiring regulations for DC installations. Ensure the MEGA-fuse rating is correctly matched to the cable cross-section and the maximum continuous current of the connected equipment. Do not install without a correctly rated MEGA-fuse cartridge in place.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47484426715470,"sku":"CIP100200100","price":28.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-modular-fuse-holder-for-mega-fuse-cip100200100-945201.jpg?v=1747941388"},{"product_id":"victron-busbar-5-mega-fuseholders-cip100400060","title":"Victron Busbar to connect 5 CIP100200100 - CIP100400060","description":"\u003ch1 style=\"color: #f87c24;\"\u003eBusbar to Connect 5 CIP100200100 MEGA Fuseholders — CIP100400060\u003c\/h1\u003e\n\n\u003cp\u003eThe CIP100400060 is a dedicated busbar designed to link up to five CIP100200100 MEGA fuseholders into a single, unified assembly. It is intended for use in DC distribution systems where multiple high-current circuits need to be consolidated at a common connection point, such as in battery banks, inverter installations and marine or vehicle electrical systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConnects up to five CIP100200100 MEGA fuseholders in a single busbar assembly.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for use with Victron MEGA fuseholder range, ensuring a precise mechanical and electrical fit.\u003c\/li\u003e\n  \u003cli\u003eSimplifies DC distribution wiring by consolidating multiple fused circuits at one point.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.17 kg, suitable for installations with limited space.\u003c\/li\u003e\n  \u003cli\u003eReduces the need for separate busbars or additional connection hardware when running multiple MEGA fuse circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe CIP100400060 busbar is a purpose-made accessory for the Victron CIP100200100 MEGA fuseholder. Rather than wiring individual fuseholders independently, this busbar allows up to five units to share a common positive or negative rail, reducing cable runs and simplifying the overall distribution layout. This is particularly useful in battery systems where several high-current loads or charge sources each require their own fused connection.\u003c\/p\u003e\n\n\u003cp\u003eUsing a matched busbar rather than improvised connections maintains consistent contact resistance across all positions and keeps the installation tidy and serviceable. The busbar is sold as a single unit and is compatible exclusively with the CIP100200100 fuseholder. Confirm the number of fuseholders required before ordering, as the busbar accommodates a fixed five-position configuration.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP100400060\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076018148\u003c\/li\u003e\n  \u003cli\u003eCompatible fuseholder: CIP100200100 (MEGA fuseholder)\u003c\/li\u003e\n  \u003cli\u003eNumber of positions: 5\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.17 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution boards in off-grid and battery-based solar installations.\u003c\/li\u003e\n  \u003cli\u003eMarine electrical systems requiring multiple fused high-current circuits.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome 12V or 24V DC distribution with several independent loads.\u003c\/li\u003e\n  \u003cli\u003eInverter and battery bank installations where multiple MEGA fuses are used on a common rail.\u003c\/li\u003e\n  \u003cli\u003eAny installation using five CIP100200100 MEGA fuseholders that benefits from a shared busbar connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x CIP100400060 busbar (for connecting 5 x CIP100200100 MEGA fuseholders)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar is a passive connection component and does not include fuseholders or fuses. The CIP100200100 MEGA fuseholders and appropriate MEGA fuses must be purchased separately. Ensure all connections are torqued to the specification stated for the fuseholder. DC distribution work at battery voltages should be carried out by a qualified electrician or experienced installer familiar with high-current DC systems. Verify that the combined current rating of the circuits connected does not exceed the rating of the busbar and associated cabling.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47484447719758,"sku":"CIP100400060","price":31.07,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/CIP100400060-bus-bar-for-mega-fuses-5-connections.jpg?v=1760305176"},{"product_id":"victron-busbar-6-mega-fuseholders-cip100400070","title":"Victron Busbar to connect 6 CIP100200100 - CIP100400070","description":"\u003ch1 style=\"color: #f87c24;\"\u003eBusbar to Connect 6 CIP100200100 MEGA Fuseholders\u003c\/h1\u003e\n\n\u003cp\u003eThis busbar is designed to link up to six Victron CIP100200100 MEGA fuseholders in a single, compact assembly. It is intended for professional DC distribution installations where multiple fused circuits need to share a common positive or negative rail. The busbar simplifies wiring, reduces the number of individual cable connections, and keeps the installation tidy and serviceable.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConnects up to six CIP100200100 MEGA fuseholders in a single busbar assembly.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for use with Victron MEGA fuseholder range, ensuring correct mechanical and electrical fit.\u003c\/li\u003e\n  \u003cli\u003eReduces point-to-point wiring between fuseholders, simplifying DC distribution layouts.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 48.5 g, suited to panel or enclosure mounting alongside MEGA fuseholders.\u003c\/li\u003e\n  \u003cli\u003eSKU CIP100400070, GTIN 8719076033004, supplied as a single busbar unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eIn DC distribution boards and battery systems, running individual cables between multiple MEGA fuseholders adds complexity and increases the risk of loose connections. This busbar provides a direct mechanical and electrical link across up to six CIP100200100 units, creating a shared common rail without additional cabling between each holder.\u003c\/p\u003e\n\n\u003cp\u003eThe busbar is a purpose-made accessory within the Victron MEGA fuseholder system. It is not a universal component. It must be used with the CIP100200100 MEGA fuseholder specifically. Using it with other fuseholder models or in configurations it was not designed for is not recommended.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP100400070\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076033004\u003c\/li\u003e\n  \u003cli\u003eCompatible fuseholder: Victron CIP100200100 MEGA fuseholder\u003c\/li\u003e\n  \u003cli\u003eMaximum fuseholders connected: 6\u003c\/li\u003e\n  \u003cli\u003eWeight: 48.5 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution panels in off-grid solar and battery storage systems.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle electrical installations using MEGA fuse protection.\u003c\/li\u003e\n  \u003cli\u003eMotorhome, campervan and caravan 12 V or 24 V DC distribution boards.\u003c\/li\u003e\n  \u003cli\u003eCommercial battery bank installations requiring multiple fused outputs from a common rail.\u003c\/li\u003e\n  \u003cli\u003eAny installation using multiple CIP100200100 MEGA fuseholders that benefits from a shared busbar connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Busbar for connecting up to 6 x CIP100200100 MEGA fuseholders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar should be installed by a qualified electrician familiar with DC distribution systems. Ensure all MEGA fuseholders are correctly seated and torqued to the manufacturer's specification before energising the circuit. Verify that the combined current load across all connected fuseholders does not exceed the rating of the busbar and associated wiring. This component is designed exclusively for use with the Victron CIP100200100 MEGA fuseholder and should not be adapted for use with other products.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47484453912910,"sku":"CIP100400070","price":36.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-to-connect-6-cip100200100-cip100400070-578386.jpg?v=1747941412"},{"product_id":"victron-mega-fuse-holder-cip000100001","title":"Victron Fuse holder for MEGA-fuse - CIP000100001","description":"\u003ch1 style=\"color: #f87c24;\"\u003eFuse Holder for MEGA-Fuse — CIP000100001\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse holder is a dedicated single-fuse housing designed to accept standard MEGA-format fuses in 12V, 24V and 48V DC systems. It is used wherever a high-current DC circuit requires a secure, accessible fuse point, including battery banks, inverter connections and busbar protection.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAccepts standard MEGA-format fuses, compatible with the full Victron MEGA-fuse range.\u003c\/li\u003e\n  \u003cli\u003eDesigned for high-current DC applications including inverter and battery protection circuits.\u003c\/li\u003e\n  \u003cli\u003eCompact housing keeps the fuse accessible for inspection and replacement without disturbing the wider installation.\u003c\/li\u003e\n  \u003cli\u003eSuitable for use across 12V, 24V and 48V DC system voltages.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 0.11 kg, making it straightforward to mount in confined enclosures or battery compartments.\u003c\/li\u003e\n  \u003cli\u003eSold individually, allowing installers to specify exactly the number of fuse points required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\n\u003cp\u003eMEGA-fuses are a widely used format in automotive and marine DC protection, rated for high continuous currents. This holder provides the correct mechanical and electrical interface for those fuses, ensuring a low-resistance, vibration-resistant connection at the fuse terminals. Using the correct holder matters: an undersized or poorly rated holder introduces resistance and heat at the fuse point, which can cause nuisance tripping or damage to the fuse before a genuine fault occurs.\u003c\/p\u003e\n\n\u003cp\u003eThis holder is the standard Victron-supplied housing for MEGA-fuses used throughout their inverter, charger and battery system installations. It is a straightforward component, but selecting the right holder for the fuse format is an important step in any DC protection design. The holder is sold without a fuse; the appropriate MEGA-fuse rating must be selected separately based on the circuit's continuous current and cable sizing.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP000100001\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076021704\u003c\/li\u003e\n  \u003cli\u003eCompatible fuse format: MEGA-fuse\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.11 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInverter DC input protection in off-grid and battery backup systems.\u003c\/li\u003e\n  \u003cli\u003eBattery bank fusing in 12V, 24V and 48V installations.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome DC distribution boards.\u003c\/li\u003e\n  \u003cli\u003eBusbar and cable protection in high-current DC circuits.\u003c\/li\u003e\n  \u003cli\u003eReplacement or additional fuse points in existing Victron system installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x MEGA-fuse holder (fuse not included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis holder should be installed as close to the positive battery terminal as practically possible to minimise unprotected cable length. Ensure the fuse rating is selected in accordance with the cable cross-section and the maximum continuous current of the connected equipment. DC wiring in battery and inverter systems carries high fault currents; installation should be carried out by a qualified electrician or experienced installer familiar with DC protection requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47484483469646,"sku":"CIP000100001","price":7.46,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-fuse-holder-for-mega-fuse-cip000100001-568357.jpg?v=1747941493"},{"product_id":"victron-battery-switch-on-off-275a","title":"Victron Battery switch ON\/OFF 275A - VBS127010010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eBattery Switch ON\/OFF 275A — VBS127010010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy Battery Switch ON\/OFF 275A is a heavy-duty manual isolation switch designed for disconnecting battery banks in marine, vehicle and off-grid installations. Rated at 275A continuous, it provides a reliable means of isolating the battery from the load circuit for maintenance, storage or emergency shutdown.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e275A continuous current rating suitable for high-load 12V and 24V battery systems.\u003c\/li\u003e\n  \u003cli\u003eSimple ON\/OFF operation for fast, positive battery isolation without tools.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 232g, suitable for panel mounting in confined spaces.\u003c\/li\u003e\n  \u003cli\u003eRobust contact design rated to handle the high inrush currents typical of inverter and motor loads.\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard busbar and battery main switch installations in marine, motorhome and off-grid applications.\u003c\/li\u003e\n  \u003cli\u003eSKU VBS127010010 with GTIN 8719076052258 for straightforward procurement and stock management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA battery isolation switch is a fundamental safety component in any DC system. It allows the battery bank to be completely disconnected from the rest of the electrical circuit, which is essential during maintenance, when the vehicle or vessel is laid up, or in the event of a fault. The 275A rating means this switch can handle the sustained current demands of inverters, bow thrusters, winches and other high-draw equipment without thermal degradation of the contacts.\u003c\/p\u003e\n\n\u003cp\u003eThe ON\/OFF design keeps operation straightforward. There is no rotary selector or multiple positions to misread: the switch is either open or closed. This matters in emergency situations where a crew member or technician needs to isolate the system quickly. The compact form factor makes it practical to mount in battery compartments, distribution panels or engine bays where space is limited.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVBS127010010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Current Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e275A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSwitch Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eON\/OFF (manual isolation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e232g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076052258\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBattery isolation on narrowboats, sailing yachts and motorboats.\u003c\/li\u003e\n  \u003cli\u003eMain battery disconnect on motorhomes, campervans and HGV auxiliary systems.\u003c\/li\u003e\n  \u003cli\u003eOff-grid cabin and caravan battery banks requiring manual isolation.\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial DC systems where a lockout-capable main switch is required.\u003c\/li\u003e\n  \u003cli\u003eReplacement or upgrade of existing battery main switches in Victron-based systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron Energy Battery Switch ON\/OFF 275A (VBS127010010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis switch should be installed by a competent electrician or qualified marine\/vehicle electrical engineer. Ensure all connections are correctly torqued and that cable sizing is appropriate for the 275A rating before commissioning. Isolate all loads before fitting or removing the switch. For installations forming part of a grid-connected or MCS-accredited solar system, work should be carried out by a qualified installer.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47486558011726,"sku":"VBS127010010","price":23.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-battery-switch-onoff-275a-vbs127010010-794475.jpg?v=1747941638"},{"product_id":"victron-mega-fuse-300a-80v-pack-of-5","title":"Victron MEGA-fuse 300A\/80V (package of 5 pcs) - CIP138300020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy MEGA-Fuse 300A\/80V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 300A\/80V is a high-current blade-style fuse designed to protect battery cables and DC wiring in 12V, 24V and 48V systems. Sold in a pack of five, it is suited to professional installers working across multiple installations or requiring on-site spares.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e300A continuous current rating for high-load DC protection applications.\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating, compatible with 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA blade-fuse format, compatible with standard MEGA fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, reducing per-unit cost and ensuring spares are available on site.\u003c\/li\u003e\n  \u003cli\u003eLightweight construction at 45g per pack, making them easy to carry in an installation kit.\u003c\/li\u003e\n  \u003cli\u003eVictron Energy part number CIP138300020, with GTIN 8719076061731 for straightforward procurement and stock management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses are a widely used format in DC electrical protection, particularly in battery-based energy systems. The 300A rating makes this fuse appropriate for main battery cable protection on larger inverter installations, where cable runs between battery banks and inverters or charge controllers carry sustained high currents. At 80V DC, the fuse covers the full operating range of 48V lithium and lead-acid battery systems without risk of arc flash on rupture.\u003c\/p\u003e\n\n\u003cp\u003eThe MEGA format uses a bolt-down blade design, which provides a low-resistance, vibration-tolerant connection compared to in-line fuse holders. This is particularly relevant in mobile and marine applications where connections are subject to movement. Victron's MEGA fuseholders are designed to accept this fuse directly, though the format is an industry standard and compatible with many third-party holders.\u003c\/p\u003e\n\n\u003cp\u003eBuying in a pack of five is practical for trade use. A single blown fuse during commissioning or a fault condition is common, and having replacements immediately available avoids delays on site.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCurrent rating: 300A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse format: MEGA blade\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003ePack weight: 0.045 kg\u003c\/li\u003e\n  \u003cli\u003eSKU: CIP138300020\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061731\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain battery cable protection on 12V, 24V and 48V inverter systems.\u003c\/li\u003e\n  \u003cli\u003eDC bus protection in off-grid solar installations.\u003c\/li\u003e\n  \u003cli\u003eBattery fusing in marine and motorhome electrical systems.\u003c\/li\u003e\n  \u003cli\u003eReplacement fusing in existing MEGA fuseholder installations.\u003c\/li\u003e\n  \u003cli\u003eSpare fuse stock for trade installers and service engineers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 300A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses must be installed in a compatible MEGA fuseholder rated for the current and voltage of the application. Ensure the fuseholder and cable terminations are correctly torqued to the manufacturer's specification to prevent resistance heating at the connection. DC systems at 300A carry significant fault energy, and all wiring, fuseholders and connections should be specified and installed by a qualified electrician or accredited installer. Always isolate the battery before replacing a fuse.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47733655372110,"sku":"CIP138300020","price":28.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/mega_fuse_victron_300Amps.webp?v=1769215681"},{"product_id":"victron-busbar-150a-2-pole-screws-cover","title":"Victron Busbar 150A 2P with 10 screws +cover - VBB115021020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eBusbar 150A 2-Pole with 10 Screws and Cover — VBB115021020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy Busbar 150A 2-Pole is a dual-pole distribution busbar rated at 150A, supplied with 10 screws and a protective cover. It is designed for use in DC distribution systems, battery banks, inverter installations and off-grid panels where multiple circuits need to be connected to a common positive or negative rail.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 150A continuous current, suitable for high-load DC distribution applications.\u003c\/li\u003e\n  \u003cli\u003e2-pole configuration allows simultaneous positive and negative rail distribution from a single component.\u003c\/li\u003e\n  \u003cli\u003eSupplied with 10 screws for securing cable lugs and connections directly to the busbar.\u003c\/li\u003e\n  \u003cli\u003eProtective cover included to guard against accidental contact with live conductors.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 148g, suitable for installation in enclosures, panels and battery cabinets.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron Energy system components including inverters, charge controllers and battery management systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA busbar provides a low-resistance, high-current connection point where multiple cables can be terminated to a single rail. In DC systems, this is essential for distributing power from a battery bank to multiple loads or charge sources without creating a tangle of point-to-point wiring. The 150A rating on this unit makes it appropriate for systems running substantial loads, such as those built around Victron Multiplus or Quattro inverters.\u003c\/p\u003e\n\n\u003cp\u003eThe 2-pole design means both the positive and negative rails are handled by a single component, which simplifies installation and keeps the wiring layout tidy. The included cover is an important safety feature: it prevents accidental short circuits and reduces the risk of contact with energised conductors during and after installation. The 10 screws provided are sufficient to connect multiple cable runs without needing additional hardware for a standard installation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: VBB115021020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 150A\u003c\/li\u003e\n  \u003cli\u003ePoles: 2\u003c\/li\u003e\n  \u003cli\u003eScrews included: 10\u003c\/li\u003e\n  \u003cli\u003eCover: Yes, included\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.148 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076056355\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution in off-grid and hybrid solar installations.\u003c\/li\u003e\n  \u003cli\u003eBattery bank wiring in van, motorhome and marine 12V or 24V systems.\u003c\/li\u003e\n  \u003cli\u003eInverter and charge controller installations requiring a central distribution point.\u003c\/li\u003e\n  \u003cli\u003eElectrical enclosures and distribution panels where multiple DC circuits originate from a common rail.\u003c\/li\u003e\n  \u003cli\u003eVictron Energy system builds requiring organised, safe busbar distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Busbar 150A 2-Pole\u003c\/li\u003e\n  \u003cli\u003e10x Fixing screws\u003c\/li\u003e\n  \u003cli\u003e1x Protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar should be installed by a qualified electrician or experienced installer familiar with DC distribution systems. Ensure all connections are torqued correctly and that the protective cover is fitted before the system is energised. For solar PV and battery installations, always follow relevant wiring regulations including BS 7671 (IET Wiring Regulations) and any applicable system-specific requirements. Disconnect all power sources before working on the busbar or any connected circuits.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":48288393527630,"sku":"VBB115021020","price":13.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-150a-2p-with-10-screws-cover-vbb115021020-198333.jpg?v=1747945909"},{"product_id":"victron-busbar-150a-2-pole-20-screws-cover","title":"Victron Busbar 150A 2P with 20 screws +cover - VBB115022020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eBusbar 150A 2-Pole with 20 Screws and Cover — VBB115022020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy Busbar 150A 2-Pole is a dual-rail distribution busbar rated at 150A, supplied with 20 screws and a protective cover. It is designed for use in DC distribution systems, battery banks, inverter installations and off-grid panels where multiple circuits need to be connected to a common positive and negative rail.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e150A continuous current rating suitable for high-current DC distribution applications.\u003c\/li\u003e\n  \u003cli\u003e2-pole design provides both positive and negative rails in a single unit, keeping wiring neat and organised.\u003c\/li\u003e\n  \u003cli\u003eSupplied with 20 screws, giving sufficient terminals for multiple circuit connections without additional hardware.\u003c\/li\u003e\n  \u003cli\u003eProtective cover included to guard against accidental contact with live conductors.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 212g, suitable for installation in enclosures, panels and battery compartments.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron Energy system components including inverters, charge controllers and battery management systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA busbar provides a central connection point for multiple cables within a DC distribution system. Rather than daisy-chaining connections or relying on individual terminal blocks, a busbar allows each circuit to connect directly to a common rail, reducing voltage drop and simplifying fault-finding. The 150A rating on this unit makes it appropriate for systems where the aggregate load across all connected circuits does not exceed that threshold.\u003c\/p\u003e\n\n\u003cp\u003eThe 2-pole configuration means both the positive and negative busbars are housed together, which is practical for installations where space is limited and a tidy, paired layout is preferred. The included protective cover is an important safety feature: it reduces the risk of accidental short circuits caused by tools or loose conductors contacting the live rails during or after installation.\u003c\/p\u003e\n\n\u003cp\u003eWith 20 screws included, this busbar can accommodate a significant number of individual circuit connections. This makes it well suited to battery banks with multiple parallel strings, inverter DC inputs, fuse holders and other distribution components that all require a common connection point.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: VBB115022020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 150A\u003c\/li\u003e\n  \u003cli\u003ePoles: 2 (positive and negative)\u003c\/li\u003e\n  \u003cli\u003eScrews included: 20\u003c\/li\u003e\n  \u003cli\u003eCover: Yes, included\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.212 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076056379\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution in off-grid solar systems with multiple loads and charge sources.\u003c\/li\u003e\n  \u003cli\u003eBattery bank positive and negative rail connections in 12V, 24V or 48V systems.\u003c\/li\u003e\n  \u003cli\u003eInverter and inverter\/charger DC input distribution panels.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome electrical systems requiring a central distribution point.\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial battery storage installations with multiple circuit outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Busbar 150A 2-Pole\u003c\/li\u003e\n  \u003cli\u003e20x Screws\u003c\/li\u003e\n  \u003cli\u003e1x Protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar should be installed by a qualified electrician familiar with DC distribution systems. Ensure the total connected load does not exceed the 150A rating of the busbar. All connections must be torqued correctly to the screw specification to avoid high-resistance joints. The protective cover must be fitted after wiring is complete. For solar PV and battery storage installations, a qualified or MCS-accredited installer is recommended.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":48288456671566,"sku":"VBB115022020","price":21.16,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-150a-2p-with-20-screws-cover-vbb115022020-257469.jpg?v=1747945924"},{"product_id":"victron-busbar-150a-4-pole-cover","title":"Victron Busbar 150A 4P +cover - VBB115040020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Busbar 150A 4-Pole with Cover — VBB115040020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 150A 4-pole busbar is a compact distribution component for DC power systems. It provides a single, secure connection point for distributing current across up to four circuits, and is supplied with a protective cover. Suited to battery banks, inverter installations and off-grid DC distribution boards where a tidy, rated connection point is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 150A continuous DC current, suitable for high-current battery and inverter distribution applications.\u003c\/li\u003e\n  \u003cli\u003e4-pole design accommodates up to four separate circuit connections from a single busbar.\u003c\/li\u003e\n  \u003cli\u003eSupplied with a protective cover to guard against accidental contact and short circuits.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.17 kg, making it straightforward to mount within enclosures or distribution panels.\u003c\/li\u003e\n  \u003cli\u003eVictron Energy component, designed to integrate with Victron system builds and third-party DC installations alike.\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076052197 — genuine Victron part, traceable and verifiable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA busbar simplifies DC distribution by replacing multiple point-to-point cable runs with a single, rated connection rail. In a 4-pole configuration, one input (typically from a battery or main fuse) feeds up to four output circuits, each independently connected. This reduces wiring complexity and the number of terminals required at the battery or inverter.\u003c\/p\u003e\n\n\u003cp\u003eThe 150A rating means this busbar is appropriate for systems drawing significant continuous current, such as those built around Victron MultiPlus or Quattro inverter-chargers, or multi-battery bank setups. The included cover is not cosmetic: it reduces the risk of accidental short circuits during installation and in service, which is a genuine safety consideration in any live DC panel.\u003c\/p\u003e\n\n\u003cp\u003eAt 0.17 kg, this is a small but functional component. It is best mounted inside a suitable enclosure or distribution board rather than left exposed.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: VBB115040020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 150A\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eCover included: Yes\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.17 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076052197\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution in off-grid solar systems with multiple load circuits.\u003c\/li\u003e\n  \u003cli\u003eBattery bank distribution points in van, motorhome and marine installations.\u003c\/li\u003e\n  \u003cli\u003eInverter and charger wiring consolidation in Victron system builds.\u003c\/li\u003e\n  \u003cli\u003eDistribution boards and enclosures requiring a compact, rated busbar with protective cover.\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial DC panel builds where circuit separation is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy 150A 4-pole busbar\u003c\/li\u003e\n  \u003cli\u003e1 x Protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar should be installed by a qualified electrician or experienced system integrator. Ensure the busbar is correctly rated for the total current of all connected circuits combined, not just individual loads. Mount within a suitable enclosure to maintain the protection offered by the cover. Always isolate the battery or power source before making connections. For installations forming part of a grid-connected or solar PV system, work should be carried out by a qualified installer in accordance with BS 7671 and any applicable G98 or G99 requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":48288467190094,"sku":"VBB115040020","price":12.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-150a-4p-cover-vbb115040020-202645.jpg?v=1747945942"},{"product_id":"victron-busbar-150a-6-position-cover","title":"Victron Busbar 150A 6P +cover - VBB115060020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Busbar 150A 6P with Cover — VBB115060020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 150A 6-position busbar with cover is a DC distribution component for use in battery banks, inverter installations and off-grid power systems. It provides a single, organised connection point for multiple circuits up to 150A continuous, reducing cable clutter and improving installation safety. Suited to professional installers working on marine, vehicle, off-grid and industrial DC systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e150A continuous current rating suitable for high-load DC distribution applications.\u003c\/li\u003e\n  \u003cli\u003e6 connection positions allow multiple circuits to be terminated at a single point.\u003c\/li\u003e\n  \u003cli\u003eProtective cover included, reducing the risk of accidental short circuits and contact with live terminals.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.26 kg, making it practical for panel mounting in confined enclosures.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron Energy battery systems, inverter\/chargers and DC distribution boards.\u003c\/li\u003e\n  \u003cli\u003eSKU VBB115060020, GTIN 8719076052203 for straightforward procurement and stock management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA busbar simplifies DC wiring by consolidating multiple cable terminations onto a single conductive bar. Rather than daisy-chaining connections or using multiple individual terminals, a busbar distributes current evenly across all connected circuits. The 150A rating on this unit means it can handle the combined load of several circuits simultaneously without thermal stress on the connections, provided the total draw does not exceed the rated current.\u003c\/p\u003e\n\n\u003cp\u003eThe 6-position layout gives installers enough terminals for a typical battery bank or inverter distribution setup, covering loads such as inverters, charge controllers, DC fuse boxes and auxiliary circuits. The included cover is a practical safety feature: it fits over the live terminals to prevent accidental contact and reduce the risk of short circuits caused by stray tools or cables during and after installation. This is particularly relevant in marine and vehicle installations where vibration and movement are factors.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: VBB115060020\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076052203\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 150A\u003c\/li\u003e\n  \u003cli\u003eNumber of positions: 6\u003c\/li\u003e\n  \u003cli\u003eCover: Included\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.26 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution in off-grid solar power systems with battery storage.\u003c\/li\u003e\n  \u003cli\u003eMarine electrical installations requiring organised, covered terminal points.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome 12V or 24V DC distribution boards.\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial battery bank wiring with multiple load circuits.\u003c\/li\u003e\n  \u003cli\u003eInverter and inverter\/charger installations requiring a central negative or positive distribution point.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy 150A 6-position busbar\u003c\/li\u003e\n  \u003cli\u003e1 x Protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar should be installed by a qualified electrician or experienced DC systems installer. Ensure all circuits connected to the busbar are individually fused or protected as close to the source as practicable. Verify that the combined current draw of all connected circuits does not exceed the 150A rated capacity of the busbar. For battery and inverter installations, disconnect all power sources before making or modifying connections. In marine applications, follow the relevant BMEA or IEC wiring standards for DC distribution.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":48288471843150,"sku":"VBB115060020","price":20.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-150a-6p-cover-vbb115060020-778195.jpg?v=1747945966"},{"product_id":"victron-busbar-250a-2-pole-6-screws-cover","title":"Victron Busbar 250A 2P with 6 screws +cover - VBB125020620","description":"\u003ch1 style=\"color: #f87c24;\"\u003eBusbar 250A 2-Pole with 6 Screws and Cover — VBB125020620\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Busbar 250A 2-Pole is a compact, high-current distribution busbar designed for use in 12V, 24V and 48V DC systems. It provides a clean, organised method of connecting multiple cables to a common positive or negative rail, and is suited to battery banks, inverter installations and off-grid distribution boards. The included protective cover reduces the risk of accidental short circuits in live installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 250A continuous current, suitable for high-load DC distribution applications.\u003c\/li\u003e\n  \u003cli\u003e2-pole configuration with 6 screw terminals for connecting multiple cables to a single rail.\u003c\/li\u003e\n  \u003cli\u003eProtective cover included, reducing the risk of accidental contact or short circuit in enclosed installations.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.25 kg, making it practical for panel mounting in tight enclosures.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron system components including inverters, battery monitors and charge controllers.\u003c\/li\u003e\n  \u003cli\u003eScrew-terminal design provides a secure, low-resistance connection for each cable run.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA busbar simplifies DC wiring by consolidating multiple cable connections onto a single conductive rail rather than daisy-chaining terminals or relying on oversized connectors. In a typical off-grid or marine installation, the positive and negative busbars act as the central distribution point between the battery bank and all loads or charge sources. This 250A rating means it can handle the combined current draw of a substantial inverter installation or multiple parallel loads without thermal stress at the connection points.\u003c\/p\u003e\n\n\u003cp\u003eThe 2-pole format provides two separate rails (positive and negative) in a single unit, keeping wiring tidy and reducing the number of separate components needed. Six screw terminals per pole give enough connection points for most small to medium system layouts. The cover is an important practical detail: in any live DC installation, an exposed busbar at 250A represents a significant short-circuit risk, and the cover mitigates this during and after installation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: VBB125020620\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 250A\u003c\/li\u003e\n  \u003cli\u003eConfiguration: 2-pole\u003c\/li\u003e\n  \u003cli\u003eNumber of screw terminals: 6 (per pole)\u003c\/li\u003e\n  \u003cli\u003eProtective cover: included\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076056386\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution in off-grid solar installations with battery storage.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat 12V or 24V system wiring hubs.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and vehicle conversion DC distribution boards.\u003c\/li\u003e\n  \u003cli\u003eCentralised connection point for inverter, battery monitor and charge controller cabling.\u003c\/li\u003e\n  \u003cli\u003ePositive and negative rail distribution in enclosed electrical enclosures or combiner boxes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Busbar 250A 2-Pole\u003c\/li\u003e\n  \u003cli\u003e6 x mounting screws\u003c\/li\u003e\n  \u003cli\u003e1 x protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar should be installed by a qualified electrician or experienced installer familiar with high-current DC systems. Ensure all cables are correctly rated for the current they will carry before connecting to the busbar. Torque all screw terminals to the manufacturer's specification to avoid loose connections and heat build-up. The protective cover must be fitted after wiring is complete. For solar PV and battery storage installations in the UK, Voltacon recommends using MCS-accredited installers where applicable.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":48288475480398,"sku":"VBB125020620","price":29.32,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-250a-2p-with-6-screws-cover-vbb125020620-738851.webp?v=1747945987"},{"product_id":"victron-busbar-250a-2-pole-12-screws-cover","title":"Victron Busbar 250A 2P with 12 screws +cover - VBB125021220","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Busbar 250A 2-Pole with 12 Screws and Cover — VBB125021220\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Busbar 250A 2P is a dual-pole busbar rated at 250A, supplied with 12 screws and a protective cover. It is designed for use in DC distribution systems, battery banks, and inverter installations where multiple cables need to be terminated at a common positive and negative point.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e250A continuous current rating suitable for high-current DC distribution applications.\u003c\/li\u003e\n  \u003cli\u003e2-pole design provides both positive and negative busbars in a single unit, simplifying wiring layouts.\u003c\/li\u003e\n  \u003cli\u003eSupplied with 12 screws, giving multiple termination points for cables and fuses.\u003c\/li\u003e\n  \u003cli\u003eProtective cover included to guard against accidental contact with live conductors.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.389 kg, suitable for panel mounting in enclosures and distribution boards.\u003c\/li\u003e\n  \u003cli\u003eVictron part number VBB125021220 for straightforward ordering and compatibility verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eBusbars are a fundamental component in any well-organised DC distribution system. Rather than daisy-chaining cables between components, a busbar provides a single, low-resistance common point where multiple conductors can be connected cleanly and securely. This is particularly important in battery-based systems where current paths need to be kept short and terminations need to be mechanically secure.\u003c\/p\u003e\n\n\u003cp\u003eThe 2-pole configuration means both the positive and negative rails are handled by one unit, which reduces the number of separate components required and keeps the installation tidy. At 250A, this busbar is rated for use with substantial inverter and battery setups, including Victron MultiPlus and Quattro installations where multiple battery cables, fuse holders, and DC loads may all need a common connection point.\u003c\/p\u003e\n\n\u003cp\u003eThe included cover is an important safety feature. It prevents accidental short circuits and protects against inadvertent contact with energised conductors during and after installation. The 12 screws provide sufficient termination points for most professional distribution panel layouts.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: VBB125021220\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 250A\u003c\/li\u003e\n  \u003cli\u003ePoles: 2 (positive and negative)\u003c\/li\u003e\n  \u003cli\u003eScrews included: 12\u003c\/li\u003e\n  \u003cli\u003eCover: Yes, included\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.389 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076056393\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution in off-grid solar systems with battery banks.\u003c\/li\u003e\n  \u003cli\u003eCommon positive and negative termination point in Victron MultiPlus or Quattro inverter installations.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome 12V or 24V DC distribution panels.\u003c\/li\u003e\n  \u003cli\u003eBattery cabinet wiring where multiple loads and charge sources share a common bus.\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial DC distribution boards requiring a rated, covered busbar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Busbar 250A 2-Pole\u003c\/li\u003e\n  \u003cli\u003e12 x Fixing screws\u003c\/li\u003e\n  \u003cli\u003e1 x Protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar should be installed by a qualified electrician familiar with DC distribution systems. Ensure all connections are torqued to the manufacturer's specification and that cables are correctly rated for the current they will carry. The protective cover must be fitted after wiring is complete. For installations forming part of a grid-connected solar system, all work should comply with current UK wiring regulations and be carried out by a suitably qualified installer.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":48288478593358,"sku":"VBB125021220","price":36.39,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-250a-2p-with-12-screws-cover-vbb125021220-109227.jpg?v=1747945996"},{"product_id":"victron-busbar-250a-4-pole-cover","title":"Victron Busbar 250A 4P +cover - VBB125040010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eBusbar 250A 4-Pole with Cover — VBB125040010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy Busbar 250A 4P is a four-pole copper busbar rated at 250A, designed for use in DC distribution systems, battery banks, and off-grid or marine electrical installations. It provides a central, secure connection point for multiple circuits and comes supplied with a protective cover to guard against accidental contact.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e250A continuous current rating, suitable for high-current DC distribution applications.\u003c\/li\u003e\n  \u003cli\u003eFour-pole configuration allows up to four separate circuit connections from a single busbar.\u003c\/li\u003e\n  \u003cli\u003eProtective cover included, reducing the risk of accidental short circuits or contact with live terminals.\u003c\/li\u003e\n  \u003cli\u003eCompact and robust construction suitable for panel mounting in battery enclosures, distribution boards and switchgear cabinets.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron Energy system components including battery main switches, fuse holders and inverter\/charger installations.\u003c\/li\u003e\n  \u003cli\u003eWeight of 0.395 kg, making it straightforward to handle and mount during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA busbar is a fundamental component in any DC distribution system. Rather than running individual cables directly between each device and the battery, a busbar provides a single, rated connection point from which multiple circuits can be distributed. This simplifies wiring, reduces the number of direct battery connections, and makes fault-finding and maintenance considerably more straightforward.\u003c\/p\u003e\n\n\u003cp\u003eThe 250A rating on this busbar means it can handle the combined load of all connected circuits up to that threshold. The four-pole design is well suited to systems where several loads or sub-circuits need to be fed from a common positive or negative rail. The included cover is a practical safety feature, particularly important in enclosed battery compartments or installations where the busbar may be accessible to non-technical personnel.\u003c\/p\u003e\n\n\u003cp\u003eThis busbar is a standard Victron Energy component and integrates naturally into Victron system builds alongside battery main switches, fuse holders, and inverter or charger wiring. It is equally applicable in non-Victron installations where a reliable, rated DC distribution point is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVBB125040010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCurrent Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e250A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eNumber of Poles\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCover Included\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.395 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076052210\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution in off-grid solar systems with multiple load circuits.\u003c\/li\u003e\n  \u003cli\u003eBattery bank positive or negative rail distribution in 12V, 24V or 48V systems.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome electrical installations requiring a central distribution point.\u003c\/li\u003e\n  \u003cli\u003eVictron MultiPlus or Quattro inverter\/charger system wiring.\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial battery storage systems requiring organised, rated DC connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Busbar 250A 4-Pole\u003c\/li\u003e\n  \u003cli\u003e1 x Protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar should be installed by a qualified electrician familiar with DC systems. Ensure all connected cables are correctly rated for their individual circuit loads and that the combined load does not exceed the 250A busbar rating. Torque all terminal connections to the manufacturer's specification to prevent resistance heating at joints. In battery systems, always disconnect the battery before making or altering busbar connections. For installations forming part of a grid-connected system, work must comply with relevant UK wiring regulations and be carried out by a suitably qualified installer.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":48288485245262,"sku":"VBB125040010","price":46.07,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-250a-4p-cover-vbb125040010-153852.jpg?v=1747946012"},{"product_id":"victron-busbar-250a-6-way-cover","title":"Victron Busbar 250A 6P +cover - VBB125060020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Busbar 250A 6-Way with Cover — VBB125060020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 250A 6-way busbar is a high-current distribution bar designed for use in 12V, 24V and 48V DC systems. It provides a single, organised connection point for distributing power from a battery or inverter to multiple circuits, and is supplied with a protective cover to guard against accidental contact and short circuits.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e250A continuous current rating, suitable for high-load DC distribution applications.\u003c\/li\u003e\n  \u003cli\u003e6 connection points (6P) allow up to six individual circuits to be fed from a single busbar.\u003c\/li\u003e\n  \u003cli\u003eSupplied with a protective cover to reduce the risk of accidental short circuits and to meet installation safety requirements.\u003c\/li\u003e\n  \u003cli\u003eCompact and robust construction, weighing 472g, suitable for panel or enclosure mounting.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron Energy system components including inverter\/chargers, battery monitors and distribution panels.\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076056416 — genuine Victron Energy product, SKU VBB125060020.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA busbar simplifies DC wiring by consolidating multiple cable connections onto a single rated conductor. Rather than running individual cables back to a battery terminal or main fuse, each load or sub-circuit connects directly to the busbar, which is then fed by a single main cable. This reduces terminal congestion, lowers the risk of loose connections and makes fault-finding considerably easier.\u003c\/p\u003e\n\n\u003cp\u003eThe 250A rating means this busbar can handle the combined current draw of multiple high-load circuits simultaneously, making it appropriate for systems with inverters, battery chargers, DC-DC converters and other demanding loads. The included cover is not merely cosmetic: it is an important safety feature in any installation where the busbar is accessible or located near conductive materials.\u003c\/p\u003e\n\n\u003cp\u003eThis busbar is a standard Victron Energy component and integrates naturally into Victron system builds, though it is equally suitable for use in any well-designed DC distribution system regardless of brand.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: VBB125060020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 250A\u003c\/li\u003e\n  \u003cli\u003eNumber of connection points: 6 (6P)\u003c\/li\u003e\n  \u003cli\u003eIncludes protective cover: Yes\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.472 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076056416\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC power distribution in off-grid solar systems with multiple loads.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat electrical installations requiring organised busbar distribution.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome conversions with high-current DC systems.\u003c\/li\u003e\n  \u003cli\u003eBattery cabinet wiring in commercial or industrial energy storage installations.\u003c\/li\u003e\n  \u003cli\u003eCentralised distribution in Victron Energy system builds alongside MultiPlus or Quattro inverter\/chargers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy 250A 6-way busbar\u003c\/li\u003e\n  \u003cli\u003e1 x Protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar must be installed by a qualified electrician or experienced DC systems installer. Ensure the main feed cable and all branch circuits are individually fused or protected by appropriately rated circuit breakers. The busbar should be mounted securely in a dry, ventilated location away from flammable materials. Always fit the protective cover once wiring is complete. For installations forming part of a grid-connected or battery storage system, work must comply with current UK wiring regulations (BS 7671) and any applicable DNO requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":48288491635022,"sku":"VBB125060020","price":50.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-250a-6p-cover-vbb125060020-896185.jpg?v=1747946044"},{"product_id":"victron-busbar-600a-4-pole-cover","title":"Victron Busbar 600A 4P +cover - VBB160040010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Busbar 600A 4-Pole with Cover — VBB160040010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 600A 4-pole busbar with cover is a high-current distribution bar designed for use in battery banks, inverter systems and DC distribution boards. It provides a single, solid connection point for distributing high-amperage DC current across up to four circuits, with a protective cover included to guard against accidental contact.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 600A continuous current, suitable for high-load DC distribution applications.\u003c\/li\u003e\n  \u003cli\u003e4-pole configuration allows connection of up to four separate cables or circuits from a single busbar.\u003c\/li\u003e\n  \u003cli\u003eProtective cover included, reducing the risk of accidental short circuits or contact with live conductors.\u003c\/li\u003e\n  \u003cli\u003eDesigned to integrate with Victron Energy system components including inverter\/chargers and battery banks.\u003c\/li\u003e\n  \u003cli\u003eCompact and robust construction at 0.716 kg, suitable for panel or enclosure mounting.\u003c\/li\u003e\n  \u003cli\u003eSKU VBB160040010, GTIN 8719076052227 for straightforward procurement and stock management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA busbar at this current rating serves as the central distribution point in any serious DC system. Rather than running multiple heavy cables directly to a battery terminal or inverter input, a busbar consolidates connections into one mechanically secure point, reducing voltage drop and simplifying cable management. At 600A, this unit is appropriate for large inverter installations, parallel battery configurations and commercial off-grid or marine DC panels.\u003c\/p\u003e\n\n\u003cp\u003eThe 4-pole layout gives the installer four connection points on a single bar, which is practical in systems where the main DC supply needs to feed several loads or sub-circuits simultaneously. The included cover is an important safety feature: it physically shields the live conductors once installation is complete, which is a requirement in many professional and commercial installations. The cover also helps protect connections from dust, debris and incidental contact in busy electrical enclosures.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVBB160040010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCurrent Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e600A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eNumber of Poles\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCover Included\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.716 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076052227\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVictron Energy\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution in large off-grid solar installations with high battery bank current.\u003c\/li\u003e\n  \u003cli\u003eParallel inverter\/charger systems requiring a central DC connection point.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome electrical panels with multiple high-current circuits.\u003c\/li\u003e\n  \u003cli\u003eCommercial battery storage systems where multiple loads share a common DC bus.\u003c\/li\u003e\n  \u003cli\u003eIndustrial DC distribution boards requiring a covered, multi-pole busbar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy 600A 4-pole busbar (VBB160040010)\u003c\/li\u003e\n  \u003cli\u003e1 x Protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar carries up to 600A and must be installed by a qualified electrician familiar with high-current DC systems. Ensure all cables are correctly rated for the intended load and that the busbar is mounted securely within an appropriate enclosure. The protective cover must be fitted after all connections are made. For solar PV and battery storage installations in the UK, work should be carried out by a suitably qualified and, where required, MCS-accredited installer.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":48288498483534,"sku":"VBB160040010","price":95.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-600a-4p-cover-vbb160040010-420529.jpg?v=1747946110"},{"product_id":"victron-mega-fuse-125a-80v-pack-5","title":"Victron MEGA-fuse 125A\/80V (package of 5 pcs) - CIP138125020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 125A\/80V (Pack of 5) — CIP138125020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 125A\/80V is a high-current blade-style fuse designed for DC protection in battery systems, inverters, and solar installations. Sold in a pack of five, it is suited to professional installers who need reliable overcurrent protection across multiple circuits or installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 125A continuous current with an 80V DC voltage rating, suitable for 12V, 24V, and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA-fuse format provides a high-current, compact form factor widely used in automotive and marine DC applications.\u003c\/li\u003e\n  \u003cli\u003eDesigned to protect wiring and equipment from overcurrent faults in inverter, battery, and DC distribution circuits.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, making it practical for trade and multi-installation use without the cost of individual purchasing.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 45g per pack, with minimal installation footprint in any fuseholder or distribution block.\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard MEGA fuseholders, including Victron's own CIP range of fuseholders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a well-established format in DC electrical protection, commonly used between battery banks and inverters, in DC busbars, and across high-current distribution systems. The 125A rating makes this fuse appropriate for protecting cable runs and equipment on 12V, 24V, and 48V systems where sustained high currents are expected. The 80V DC voltage rating provides adequate headroom for 48V battery systems, including lithium battery banks that may reach higher charge voltages.\u003c\/p\u003e\n\n\u003cp\u003eThe fuse acts as the last line of protection against wiring faults and short circuits. Correct fuse selection is critical: the fuse should be rated to protect the cable, not the load. A 125A fuse is typically paired with cable capable of carrying that current continuously, and should be installed as close to the positive terminal of the battery as practically possible to minimise unprotected cable length.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP138125020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 125A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.045 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061670\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection between battery banks and inverters or inverter\/chargers on 12V, 24V, and 48V systems.\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards and busbar protection in off-grid and marine installations.\u003c\/li\u003e\n  \u003cli\u003eProtection of high-current DC cable runs in motorhome, caravan, and commercial vehicle builds.\u003c\/li\u003e\n  \u003cli\u003eReplacement fusing in existing MEGA fuseholder installations during service or upgrade work.\u003c\/li\u003e\n  \u003cli\u003eMulti-circuit DC protection in solar off-grid systems with high battery discharge currents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 125A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses must be installed in a compatible MEGA fuseholder rated for the current and voltage of the application. The fuse should be positioned as close to the battery positive terminal as possible to protect the full length of the cable run. DC electrical work on battery systems, particularly those involving inverters or lithium battery banks, should be carried out by a qualified electrician or accredited installer. Always verify that the cable cross-section is correctly matched to the fuse rating before installation.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50670165164366,"sku":"CIP138125020","price":28.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-energy-125-amp-80-volt-mega-fuse-CIP138125020copy.jpg?v=1747948492"},{"product_id":"victron-mega-fuse-80a-80v-pack-of-5","title":"Victron MEGA-fuse 80A\/80V (package of 5 pcs) - CIP138080020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 80A\/80V (Pack of 5) — CIP138080020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 80A\/80V is a high-current blade-style fuse designed for DC protection in battery systems, inverters and other high-current 12V, 24V and 48V DC installations. Supplied in a pack of five, this fuse is the correct replacement or installation component for use with compatible MEGA fuseholders.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 80A continuous current with an 80V DC voltage rating, suitable for 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA-style blade fuse format, compatible with standard MEGA fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eProvides overcurrent protection for DC wiring between batteries, inverters, charge controllers and distribution busbars.\u003c\/li\u003e\n  \u003cli\u003eCompact, bolt-down design ensures a low-resistance, secure connection in high-current circuits.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a pack of 5, making them practical for installers carrying spares or commissioning multiple systems.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 45g per pack, with minimal installation footprint.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses are a widely used format in automotive, marine and off-grid solar DC systems. The bolt-down terminal design gives a more secure and lower-resistance connection than standard blade fuses, making them appropriate for sustained high-current loads. At 80A, this fuse is commonly used on the main battery feed to smaller inverters, on individual battery outputs in parallel bank configurations, or on DC distribution circuits where branch protection is required.\u003c\/p\u003e\n\n\u003cp\u003eThe 80V DC rating means this fuse is suitable across the full range of common battery voltages used in off-grid and backup power systems, including 12V, 24V and 48V nominal systems. It is important to select a fuse rated for DC use specifically, as AC-rated fuses do not interrupt DC fault currents in the same way. These fuses are manufactured to work within Victron's MEGA fuseholder range, though they are compatible with any standard MEGA-format holder.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP138080020\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 80A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.045 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061656\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain battery feed protection for 12V and 24V inverters and inverter\/chargers.\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection in DC distribution boards and busbar systems.\u003c\/li\u003e\n  \u003cli\u003eIndividual battery protection in parallel battery bank installations.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome DC systems requiring MEGA-format fuse protection.\u003c\/li\u003e\n  \u003cli\u003eOff-grid solar installations with high-current DC cabling between batteries and loads.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MEGA fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 80A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses must be installed in a compatible MEGA fuseholder. Always size fusing according to the cable cross-section being protected, not solely the load rating. DC fusing must be rated for DC voltage; do not substitute AC-rated fuses in DC circuits. For inverter and battery system installations, a qualified electrician or MCS-accredited installer should carry out all high-current DC wiring. Ensure the system is fully isolated before replacing any fuse.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52839568867662,"sku":"CIP138080020","price":28.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/mega-fuse-60a32v-package-of-5-pcs-cip136060010-397618.jpg?v=1747950279"},{"product_id":"mega-fuse-400a-80v-victron-pack-of-5","title":"Victron MEGA-fuse 400A\/80V (package of 5 pcs) - CIP138400020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA Fuse 400A\/80V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MEGA fuse 400A\/80V is a high-current blade-style fuse designed to protect battery cables and DC wiring in solar, off-grid and marine electrical systems. Sold in a pack of five, it is suited to professional installers who need reliable overcurrent protection at 400A continuous rating with an 80V DC voltage rating.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e400A continuous current rating for high-load DC circuits.\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating, compatible with 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA blade fuse format, compatible with standard MEGA fuseholders.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, providing spares for commissioning and ongoing maintenance.\u003c\/li\u003e\n  \u003cli\u003eDesigned for use in battery protection, inverter input and high-current DC distribution applications.\u003c\/li\u003e\n  \u003cli\u003eLightweight construction at 45g per pack, minimising additional load in compact installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses are a widely used format in DC electrical protection, particularly in battery-based systems where high fault currents can cause rapid cable damage or fire risk. The 400A rating makes this fuse appropriate for large inverter installations, battery banks and high-current DC busbars where standard ANL or blade fuses would be undersized.\u003c\/p\u003e\n\n\u003cp\u003eThe 80V DC voltage rating covers all common battery voltages used in off-grid and marine systems, including 12V, 24V and 48V configurations. It is important to select a fuse with a voltage rating at or above the system voltage to ensure the fuse can safely interrupt fault current without arcing. This fuse meets that requirement across the full range of typical Victron system voltages.\u003c\/p\u003e\n\n\u003cp\u003eVictron specifies MEGA fuses for use with their MEGA fuseholders, which are sold separately. The fuse is a consumable component and should be replaced after any overcurrent event. Keeping a pack of five on site means replacements are available during commissioning or in the event of a fault.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP138400020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 400A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.045 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061748\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBattery cable protection on 12V, 24V and 48V DC systems.\u003c\/li\u003e\n  \u003cli\u003eInverter input fusing on high-current installations.\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards and busbars in off-grid solar systems.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle electrical systems requiring high-current overcurrent protection.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MEGA fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron MEGA fuse 400A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses must be installed in a compatible MEGA fuseholder (sold separately). Always isolate the battery bank before replacing or installing fuses. Fuse selection should be based on cable rating and system design, not solely on inverter or load current draw. For battery systems above 48V or in grid-connected installations, a qualified electrician or MCS-accredited installer should carry out all wiring and protection work. Never bypass or replace a blown fuse with a higher-rated fuse without first identifying and resolving the cause of the overcurrent event.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59256378032462,"sku":"CIP138400020","price":28.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/mega_fuse_victron_400Amps_ddc80866-6448-4c06-a54e-429e8f43c16f.webp?v=1774534896"},{"product_id":"victron-anl-fuse-holder-cip106100000","title":"Victron Fuse holder for ANL-fuse - CIP106100000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Fuse Holder for ANL Fuse\u003c\/h1\u003e\n\n\u003cp\u003eThis is the dedicated fuse holder for ANL-type fuses from Victron Energy. It is designed for use in 12V, 24V and 48V DC battery systems where high-current overcurrent protection is required. A correctly rated fuse holder is a fundamental part of any safe battery installation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned specifically to accept ANL-type fuses for a secure, low-resistance connection.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.1 kg, suitable for installation in confined battery compartments.\u003c\/li\u003e\n  \u003cli\u003eProvides a dedicated, purpose-built mounting point for ANL fuses rather than improvised alternatives.\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard ANL fuse installations in 12V, 24V and 48V DC battery systems.\u003c\/li\u003e\n  \u003cli\u003eVictron Energy part number CIP106100000, ensuring correct replacement or system build sourcing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eANL fuses are a common choice for high-current DC protection in battery banks, inverter installations and marine or vehicle electrical systems. The fuse alone requires a properly rated holder to function correctly. This Victron fuse holder provides the mechanical support and electrical termination points needed to mount an ANL fuse safely in-line with the main DC cabling.\u003c\/p\u003e\n\n\u003cp\u003eUsing a matched fuse holder ensures the contact surfaces are correctly rated for the current passing through the fuse. Undersized or poorly fitted holders can introduce resistance, cause heat build-up, or fail to hold the fuse securely under vibration. This holder is the correct accessory to pair with Victron ANL fuses in any DC protection circuit.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP106100000\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076033868\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.1 kg\u003c\/li\u003e\n  \u003cli\u003eCompatible fuse type: ANL\u003c\/li\u003e\n  \u003cli\u003eBrand: Victron Energy\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain DC overcurrent protection in battery bank installations.\u003c\/li\u003e\n  \u003cli\u003eInverter and inverter\/charger DC input protection in off-grid and backup power systems.\u003c\/li\u003e\n  \u003cli\u003eMarine electrical systems requiring in-line ANL fuse protection.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome leisure battery installations.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuse holder in existing Victron ANL fuse installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy fuse holder for ANL fuse (CIP106100000)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis fuse holder should be installed by a qualified electrician or experienced installer familiar with DC battery systems. Ensure the fuse rating is appropriate for the cable size and the connected load. All DC connections must be torqued correctly and the fuse holder positioned to allow safe fuse replacement. For inverter and battery installations, follow Victron Energy wiring guidelines and relevant BS 7671 requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59855248228686,"sku":"CIP106100000","price":6.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP106100000_-_Fuse_holder_for_ANL-fuse.webp?v=1781091841"},{"product_id":"victron-midi-fuse-holder-cip000050001","title":"Victron Fuse holder for MIDI-fuse - CIP000050001","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Fuse Holder for MIDI Fuse\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MIDI fuse holder is a dedicated mounting and connection component for MIDI-type fuses. It is designed for use in 12V, 24V and 48V DC systems where a reliable, serviceable fuse point is required, including battery protection, inverter wiring and busbar connections.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCompatible with standard MIDI fuses, allowing straightforward fuse replacement in the field.\u003c\/li\u003e\n  \u003cli\u003eCompact form factor suited to tight wiring enclosures and battery compartments.\u003c\/li\u003e\n  \u003cli\u003eDesigned for use in DC protection circuits across a wide range of system voltages.\u003c\/li\u003e\n  \u003cli\u003eVictron Energy part number CIP000050001, ensuring direct compatibility with Victron MIDI fuse ranges.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 24g, minimising added weight in mobile and marine installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses are a widely used format in DC electrical systems, particularly for protecting high-current cables between batteries and inverters or charge controllers. This fuse holder provides the mechanical housing and electrical termination points needed to mount a MIDI fuse correctly in a circuit. Without a proper holder, MIDI fuses cannot be safely or reliably integrated into a wiring run.\u003c\/p\u003e\n\n\u003cp\u003eThe holder is built to Victron's component standards and is intended for use alongside Victron MIDI fuses. It suits installations where the fuse must be accessible for inspection or replacement, such as in battery banks, inverter feeds and DC distribution boards. The low weight makes it practical for van conversions, marine craft and other weight-sensitive applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP000050001\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076021681\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.024 kg (24g)\u003c\/li\u003e\n  \u003cli\u003eCompatible fuse type: MIDI fuse\u003c\/li\u003e\n  \u003cli\u003eBrand: Victron Energy\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBattery to inverter DC cable protection in off-grid and mobile systems.\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards and busbar fuse protection points.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat 12V and 24V electrical installations.\u003c\/li\u003e\n  \u003cli\u003eVan and motorhome leisure battery wiring.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuse holder in existing Victron system installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy fuse holder for MIDI fuse (fuse not included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis fuse holder should be installed by a competent electrician or qualified installer familiar with DC wiring practices. Ensure the correct MIDI fuse rating is selected for the cable and load being protected. The holder must be securely mounted and all terminals tightened to the appropriate torque. For inverter and battery connections in larger systems, a qualified installer is recommended.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59855248261454,"sku":"CIP000050001","price":6.11,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP000050001_-_Fuse_holder_for_MIDI-fuse.webp?v=1781091846"},{"product_id":"victron-midi-fuse-125a-32v-pack-of-5","title":"Victron MIDI-fuse 125A\/32V (package of 5 pcs) - CIP132125010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy MIDI Fuse 125A\/32V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MIDI fuse is a 125A, 32V DC bolt-down fuse designed for use in 12V and 24V battery systems. Supplied in a pack of five, it is suited to professional installers and system builders who need reliable overcurrent protection for DC cabling in solar, off-grid and marine applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 125A continuous current with a 32V DC voltage rating.\u003c\/li\u003e\n  \u003cli\u003eMIDI form factor, compatible with standard MIDI fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eBolt-down blade design provides a low-resistance, secure connection in high-current DC circuits.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a pack of 5, reducing per-unit cost for multi-system installations or service stock.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 11g per pack, making them practical to carry as spares on site.\u003c\/li\u003e\n  \u003cli\u003eSKU CIP132125010, GTIN 8719076054658, sourced directly from Victron Energy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses are a compact, bolt-down fuse format widely used in DC battery protection circuits. The 125A rating makes this fuse appropriate for protecting main DC cables in 12V and 24V systems, including battery-to-inverter runs, busbar feeds and charge controller output wiring. At 32V DC, the voltage rating comfortably covers both 12V and 24V nominal battery banks.\u003c\/p\u003e\n\n\u003cp\u003eUsing the correct fuse rating for the cable cross-section is essential. A 125A fuse is typically paired with 35mm² to 50mm² DC cable, depending on cable length and installation conditions. Victron MIDI fuses are designed to work with Victron MIDI fuseholders, ensuring a consistent contact interface and avoiding the resistance issues that can arise from mismatched fuse and holder combinations.\u003c\/p\u003e\n\n\u003cp\u003eBuying in packs of five is practical for installers completing multiple systems or for keeping service stock on hand. MIDI fuses are a consumable item and having spares available on site avoids delays when a fuse operates during commissioning or fault conditions.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP132125010\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 125A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 32V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MIDI bolt-down blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.011 kg per pack\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076054658\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on main DC battery cables in 12V and 24V off-grid solar systems.\u003c\/li\u003e\n  \u003cli\u003eFusing battery-to-inverter connections in mobile, marine and vehicle installations.\u003c\/li\u003e\n  \u003cli\u003eProtecting DC distribution feeds from battery banks to busbars or combiners.\u003c\/li\u003e\n  \u003cli\u003eService and replacement stock for installers maintaining existing Victron-based systems.\u003c\/li\u003e\n  \u003cli\u003eMulti-system installation projects where several fuses are required across a single job.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MIDI fuse, 125A\/32V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses must be installed in a compatible MIDI fuseholder. Ensure the fuseholder is rated for the current and voltage of the circuit. DC fusing in battery systems should be installed as close to the positive battery terminal as practicable to protect the full cable run. All DC wiring and fusing work on battery systems should be carried out by a qualified electrician or accredited installer familiar with DC system design. Do not substitute a higher-rated fuse than the cable is rated to carry.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59855248916814,"sku":"CIP132125010","price":7.64,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP132125010_-_MIDI-fuse_125A-32V_package_of_5_pcs.webp?v=1781091876"},{"product_id":"victron-600a-8-position-busbar-cover","title":"Victron Busbar 600A 8P +cover - VBB160080010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Busbar 600A 8-Position with Cover\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 600A 8-position busbar is a heavy-duty DC distribution component designed for use in battery banks, inverter systems and off-grid power installations. It provides a single, organised connection point for multiple high-current circuits, reducing cable clutter and improving system safety. Suitable for professional installers working on marine, vehicle, off-grid and industrial DC systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 600A continuous current, suitable for high-load DC distribution applications.\u003c\/li\u003e\n  \u003cli\u003e8 connection positions allow multiple circuits to be fed from a single busbar without additional junction hardware.\u003c\/li\u003e\n  \u003cli\u003eProtective cover included, reducing the risk of accidental short circuits and improving installation safety.\u003c\/li\u003e\n  \u003cli\u003eDesigned to accept large-section cables and lugs typical of battery and inverter wiring.\u003c\/li\u003e\n  \u003cli\u003eVictron Energy component, compatible with Victron system builds and third-party DC installations.\u003c\/li\u003e\n  \u003cli\u003eWeight of 1.228 kg indicates solid, heavy-gauge construction appropriate for high-current use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA busbar at this current rating serves as the central distribution point in a DC system, connecting the battery bank or main supply to multiple loads or sub-circuits. Rather than running individual cables back to the battery terminals, all circuits terminate at the busbar, which carries the combined current from a single, well-rated connection. This simplifies wiring, reduces the number of connections at the battery, and makes fault-finding and circuit isolation more straightforward.\u003c\/p\u003e\n\n\u003cp\u003eThe 8-position format is well suited to systems with several inverters, charge controllers, DC loads or battery strings that each require their own dedicated connection. The included cover is an important safety feature: it prevents tools, debris or accidental contact from bridging the busbar terminals, which at 600A would present a serious arc and fire risk. For any professional installation, a covered busbar is the correct choice over an open bar.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: VBB160080010\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 600A\u003c\/li\u003e\n  \u003cli\u003eNumber of positions: 8\u003c\/li\u003e\n  \u003cli\u003eCover: Included\u003c\/li\u003e\n  \u003cli\u003eWeight: 1.228 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076052234\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBattery bank distribution in off-grid solar systems with multiple charge controllers or inverters.\u003c\/li\u003e\n  \u003cli\u003eDC distribution in marine electrical systems requiring multiple high-current feeds.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome conversions with complex 12V or 24V DC wiring.\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial off-grid installations with several DC loads.\u003c\/li\u003e\n  \u003cli\u003eCentralised negative or positive distribution in large Victron MultiPlus or Quattro system builds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy 600A 8-position busbar\u003c\/li\u003e\n  \u003cli\u003e1 x Protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar should be installed by a qualified electrician or experienced system integrator familiar with high-current DC wiring. At 600A, incorrect installation, undersized cabling or loose connections present a significant risk of fire or equipment damage. Ensure all cables are correctly rated, terminated with appropriate lugs, and torqued to the manufacturer's specification. The protective cover must be fitted after wiring is complete. For installations forming part of a grid-connected solar system, all work must comply with relevant UK wiring regulations and be carried out by a suitably qualified installer.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59855392309582,"sku":"VBB160080010","price":152.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_VBB160080010_-_Busbar_600A_8P_cover.webp?v=1781094265"},{"product_id":"victron-midi-fuse-40a-58v-m6-pack-of-5","title":"Victron MIDI-fuse 40A\/58V-M6 (package of 5 pcs) - CIP134040020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MIDI Fuse 40A\/58V M6 (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MIDI fuse 40A\/58V with M6 bolt connection is a blade-style DC fuse designed for use in 12V, 24V and 48V battery systems. Sold in packs of five, it is suited to professional installers who need reliable overcurrent protection on DC cabling in solar, off-grid and marine applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e40A current rating with a 58V DC voltage rating, suitable for 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eM6 bolt termination for a secure, low-resistance connection in MIDI fuseholders.\u003c\/li\u003e\n  \u003cli\u003eMIDI form factor, compatible with standard MIDI fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, providing spares for commissioning, servicing or multi-circuit installations.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 15g per pack, with minimal installation footprint.\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061540, confirming genuine Victron Energy product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses are a widely used format in DC electrical systems, offering a compact body with bolt-down terminations. The M6 fixing means the fuse seats firmly in its holder without risk of vibration-induced loosening, which matters in mobile and marine installations. The 58V rating gives adequate headroom for 48V battery banks, including lithium systems that may reach higher resting voltages.\u003c\/p\u003e\n\n\u003cp\u003eAt 40A, this fuse is appropriate for protecting DC cables feeding loads such as inverters, charge controllers or distribution busbars in smaller off-grid systems. Selecting the correct fuse rating for the cable cross-section is essential: the fuse must protect the cable, not just the load. Always verify that the 40A rating matches the ampacity of the installed cable before fitting.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP134040020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 40A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 58V DC\u003c\/li\u003e\n  \u003cli\u003eTermination: M6 bolt\u003c\/li\u003e\n  \u003cli\u003eForm factor: MIDI\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.015 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061540\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on DC cables in 12V, 24V and 48V off-grid solar systems.\u003c\/li\u003e\n  \u003cli\u003eFuse replacement or commissioning spares in installations using Victron MIDI fuseholders.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome DC distribution boards where MIDI fuses are specified.\u003c\/li\u003e\n  \u003cli\u003eBattery-to-busbar or battery-to-inverter cable protection in small to mid-size battery systems.\u003c\/li\u003e\n  \u003cli\u003eMulti-circuit DC panels requiring individual cable protection at 40A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron MIDI fuse 40A\/58V M6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses must be installed in a compatible MIDI fuseholder rated for the voltage and current of the circuit. Ensure the M6 bolt is torqued to the fuseholder manufacturer's specification to maintain a reliable connection. Fuse selection must be based on the cable ampacity of the circuit being protected, not solely on the load rating. For battery and solar DC installations, installation by a qualified electrician is recommended. High-voltage battery systems (above 120V DC) require specialist installation and these fuses are not rated for such voltages.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59855393096014,"sku":"CIP134040020","price":9.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP134040020_-_MIDI-fuse_40A-58V-M6_package_of_5_pcs.webp?v=1781094305"},{"product_id":"victron-shunt-1000a-50mv-2xm10","title":"Victron Shunt 1000A\/50mV-0,5 \/ 2xM10 - SHU102050200","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Shunt 1000A\/50mV with 2xM10 Terminals\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 1000A\/50mV shunt is a precision current measurement component used in battery monitoring systems. It is designed for use with Victron BMV battery monitors and compatible energy meters, and suits high-current DC applications in off-grid, marine, and commercial installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 1000A continuous with a 50mV full-scale voltage drop, providing accurate current measurement across a wide load range.\u003c\/li\u003e\n  \u003cli\u003eDual M10 bolt terminals for secure, low-resistance connections to heavy-gauge DC cabling.\u003c\/li\u003e\n  \u003cli\u003eCompact, solid-construction design suitable for installation in battery enclosures, distribution boards, and switchgear panels.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron BMV-700, BMV-712, and other Victron battery monitoring equipment that accepts a 50mV shunt input.\u003c\/li\u003e\n  \u003cli\u003eCalibrated to 0.5% accuracy class, ensuring reliable state-of-charge and current data in monitoring applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA shunt works by inserting a known, very low resistance into the main DC current path. The voltage drop across this resistance is proportional to the current flowing through it. At 1000A, this shunt produces exactly 50mV, which the connected battery monitor reads and converts into an accurate current figure. The 50mV standard is widely used across Victron's monitoring range, making this shunt a direct replacement or upgrade component in existing systems.\u003c\/p\u003e\n\n\u003cp\u003eThe M10 terminal bolts are sized for the heavy-gauge cable typically used in high-current battery banks, inverter connections, and DC distribution systems. Proper torque on the terminal connections is important: under-tightened connections at this current rating will cause localised heating and measurement error. The shunt should be installed in the negative conductor between the battery negative terminal and all other loads and charge sources, as is standard practice for single-shunt battery monitoring.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: SHU102050200\u003c\/li\u003e\n  \u003cli\u003eRated current: 1000A continuous\u003c\/li\u003e\n  \u003cli\u003eVoltage drop at rated current: 50mV\u003c\/li\u003e\n  \u003cli\u003eAccuracy class: 0.5%\u003c\/li\u003e\n  \u003cli\u003eTerminal type: 2x M10 bolts\u003c\/li\u003e\n  \u003cli\u003eWeight: 1 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076026198\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBattery current monitoring in off-grid solar systems with high-capacity battery banks.\u003c\/li\u003e\n  \u003cli\u003eMarine DC systems where accurate state-of-charge monitoring is required.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and vehicle conversion builds with large lithium or AGM battery installations.\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial UPS or backup power systems using Victron BMV monitors.\u003c\/li\u003e\n  \u003cli\u003eReplacement shunt in existing Victron monitoring installations requiring a higher current rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron Energy 1000A\/50mV shunt with 2x M10 terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis shunt carries the full DC current of the battery system and must be installed correctly to avoid measurement errors and potential hazards. It should be fitted in the negative main conductor, with all negative returns connected to the load side of the shunt. Only the battery negative connects to the battery side. Connections must be torqued to the appropriate specification for M10 terminals. Installation in high-current DC systems should be carried out by a qualified electrician or experienced solar installer familiar with DC battery systems.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59855399715150,"sku":"SHU102050200","price":59.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_SHU102050200_-_Shunt_1000A-50mV-0_5_-_2xM10.webp?v=1781094377"},{"product_id":"mega-fuse-40a-80v-pack-5","title":"Victron MEGA-fuse 40A\/80V (package of 5 pcs) - CIP138040020","description":"\u003ch1 style=\"color:#f87c24\"\u003eMEGA-fuse 40A\/80V (CIP138040020) - Pack of 5\u003c\/h1\u003e\n\n\u003cp\u003eVictron MEGA-fuses provide reliable DC circuit protection for solar installations, battery systems, and off-grid power setups. This pack contains five 40A\/80V fuses, sized for medium-current applications in 12V, 24V, and 48V systems. MEGA-fuses are the standard choice for protecting inverters, chargers, and battery interconnects where space and current capacity matter\u003c\/p\u003e\n\n\u003ch3 style=\"color:#f87c24\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e40A current rating, 80V DC voltage rating\u003c\/li\u003e\n\u003cli\u003eMEGA-fuse format (larger than standard automotive fuses)\u003c\/li\u003e\n\u003cli\u003ePack of 5 fuses\u003c\/li\u003e\n\u003cli\u003eFast-acting protection for DC circuits\u003c\/li\u003e\n\u003cli\u003eSuitable for 12V, 24V, and 48V systems\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#f87c24\"\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are cylindrical cartridge fuses designed for higher current applications than standard fuses. The 40A rating makes them ideal for battery interconnects, inverter input circuits, and charger protection in medium-sized renewable energy systems. The 80V DC rating ensures safe operation across common battery voltages. Victron fuses are manufactured to strict tolerances and provide consistent, predictable protection.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#f87c24\"\u003eTechnical Specs\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMEGA-fuse (cartridge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity per Pack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCIP138040020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#f87c24\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery interconnect protection in multi-battery systems\u003c\/li\u003e\n\u003cli\u003eInverter input circuit protection\u003c\/li\u003e\n\u003cli\u003eBattery charger protection\u003c\/li\u003e\n\u003cli\u003eSolar array combiner boxes\u003c\/li\u003e\n\u003cli\u003eOff-grid and hybrid power systems\u003c\/li\u003e\n\u003cli\u003eMarine and RV electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#f87c24\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e5x MEGA-fuse 40A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#f87c24\"\u003eInstallation \u0026amp; Safety\u003c\/h3\u003e\n\u003cp\u003eInstall MEGA-fuses in a compatible MEGA-fuseholder. Always match the fuse rating to the circuit design and wire gauge. Never exceed the 80V DC rating. Keep spare fuses on site for emergency replacement. If a fuse blows repeatedly, investigate the underlying circuit fault rather than replacing with a higher-rated fuse. Ensure the fuseholder is rated for the same voltage and current specifications.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59855732670798,"sku":"CIP138040020","price":28.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP138040020_-_MEGA-fuse_40A-80V_package_of_5_pcs.webp?v=1781098503"},{"product_id":"victron-mega-fuse-175a-80v-pack-5","title":"Victron MEGA-fuse 175A\/80V (package of 5 pcs) - CIP138175020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy MEGA-Fuse 175A\/80V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 175A\/80V is a high-current DC fuse designed to protect battery cables and electrical circuits in 12V, 24V and 48V systems. Supplied in a pack of five, it is suited to professional installers working on off-grid, marine, vehicle and battery storage installations where reliable overcurrent protection is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e175A continuous current rating provides overcurrent protection for heavy-gauge DC battery cables.\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating makes it compatible with 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA-fuse format is a widely used standard in automotive and marine DC protection applications.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, suitable for stocking or multi-installation projects.\u003c\/li\u003e\n  \u003cli\u003eVictron Energy part number CIP138175020, compatible with standard MEGA fuseholders.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 45g per pack, with minimal installation footprint.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a bolt-down DC fuse format commonly used to protect main battery cables in inverter, charger and battery management installations. The 175A rating sits between typical 150A and 200A options, making it appropriate where cable sizing or equipment ratings call for a tighter protection threshold. The 80V DC rating covers all standard lead-acid and lithium battery voltages up to 48V nominal with adequate margin.\u003c\/p\u003e\n\n\u003cp\u003eThese fuses are designed for use with MEGA fuseholders, which accept the standard MEGA blade body and secure the fuse via bolt terminals. Correct fuse selection depends on cable cross-section, ambient temperature and the continuous current draw of the connected equipment. Always select a fuse rating that protects the cable, not just the load.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP138175020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 175A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.045 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061694\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain battery cable protection in off-grid solar installations with Victron inverters or inverter\/chargers.\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in marine electrical systems.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome leisure battery installations.\u003c\/li\u003e\n  \u003cli\u003eBattery bank protection in 12V, 24V and 48V energy storage systems.\u003c\/li\u003e\n  \u003cli\u003eReplacement fusing for existing MEGA fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 175A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses must be installed in a compatible MEGA fuseholder rated for the application voltage and current. Fuses should be fitted as close to the battery positive terminal as practicable to provide maximum cable protection. DC electrical work on battery systems, particularly those above 48V or with high short-circuit current capacity, should be carried out by a qualified electrician or accredited installer. Verify that the fuse rating is appropriate for the cable cross-section in use before installation.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59856059629902,"sku":"CIP138175020","price":28.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP138175020_-_MEGA-fuse_175A-80V_package_of_5_pcs.webp?v=1781101989"},{"product_id":"victron-midi-fuse-100a-58v-m6-pack-5","title":"Victron MIDI-fuse 100A\/58V-M6 (package of 5 pcs) - CIP134100020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MIDI Fuse 100A\/58V M6 (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MIDI fuse 100A\/58V with M6 bolt connection is a blade-style DC fuse designed for use in battery and solar systems where overcurrent protection is required on high-current DC cables. Sold in packs of five, these fuses are suited to professional installers who need reliable, repeatable protection across multiple installations or battery strings.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100A rated current with a 58V DC voltage rating, suitable for 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eM6 bolt terminal connection for a secure, low-resistance contact in MIDI fuseholders.\u003c\/li\u003e\n  \u003cli\u003eMIDI form factor, compatible with standard MIDI fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eSold as a pack of 5, reducing per-unit cost for trade and multi-installation use.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 15g per pack, with minimal footprint for installation in tight enclosures or battery compartments.\u003c\/li\u003e\n  \u003cli\u003eSKU CIP134100020, GTIN 8719076061595 for straightforward ordering and stock management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses are a widely used format in DC electrical protection, particularly in battery-based energy systems, marine installations and off-grid setups. The 100A rating makes this fuse appropriate for protecting main DC cables in systems where sustained high-current draw is expected, such as inverter feeds, battery interconnects or charge controller outputs. The 58V voltage rating covers the full operating range of 48V battery banks, including the elevated voltages seen during charging.\u003c\/p\u003e\n\n\u003cp\u003eThe M6 bolt terminal ensures a firm mechanical connection within the fuseholder, which is important in mobile or vibration-prone environments such as vehicles, boats and caravans. A loose or corroded fuse connection can introduce resistance and heat, so the bolted MIDI format is preferred over blade fuses in higher-current DC applications. These fuses are single-use protection devices and must be replaced after any overcurrent event.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP134100020\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061595\u003c\/li\u003e\n  \u003cli\u003eRated current: 100A\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 58V DC\u003c\/li\u003e\n  \u003cli\u003eTerminal type: M6 bolt\u003c\/li\u003e\n  \u003cli\u003eForm factor: MIDI\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.015 kg (per pack)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on DC cables in 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eInverter and inverter\/charger feed protection in off-grid and backup power installations.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat DC distribution boards and battery banks.\u003c\/li\u003e\n  \u003cli\u003eMotorhome, caravan and vehicle conversion DC wiring protection.\u003c\/li\u003e\n  \u003cli\u003eSolar charge controller output protection in standalone PV systems.\u003c\/li\u003e\n  \u003cli\u003eBattery string protection in multi-battery off-grid installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron MIDI fuse 100A\/58V M6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses must be installed in a compatible MIDI fuseholder rated for the voltage and current of the circuit. Ensure the M6 bolt is torqued to the fuseholder manufacturer's specification to maintain a low-resistance connection. DC electrical work on battery systems, inverters and solar installations should be carried out by a qualified electrician or accredited installer. Always isolate the battery before replacing a fuse. Do not use these fuses in AC circuits or in applications exceeding 58V DC.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59856059695438,"sku":"CIP134100020","price":9.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP134100020_-_MIDI-fuse_100A-58V-M6_package_of_5_pcs.webp?v=1781101993"},{"product_id":"victron-shunt-500a-50mv","title":"Victron Shunt 500A\/50mV - SHU500050100","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Shunt 500A\/50mV\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 500A\/50mV shunt is a precision current measurement component used in battery monitoring and energy management systems. It is designed for use with compatible Victron battery monitors and BMV series devices, allowing accurate measurement of charge and discharge current in 12V, 24V and 48V DC systems. Suitable for solar, off-grid, marine and vehicle installations where reliable current sensing is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 500A continuous with a 50mV voltage drop at full rated current, giving a shunt resistance of 0.1 milliohms.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron BMV battery monitors and other devices that accept a 50mV shunt input signal.\u003c\/li\u003e\n  \u003cli\u003eCompact and robust construction suitable for installation in battery enclosures, distribution boards and switchgear panels.\u003c\/li\u003e\n  \u003cli\u003eProvides the current measurement reference point for accurate state-of-charge calculations in battery monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 0.3kg, making it straightforward to mount in space-constrained installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA shunt works by inserting a known, very low resistance into the main current path. The voltage drop across it is proportional to the current flowing through it. At 500A, this shunt produces exactly 50mV, which the connected battery monitor reads and converts into an accurate current figure. The 50mV standard is widely used across the industry, so this shunt is also compatible with third-party monitors that accept a 50mV input.\u003c\/p\u003e\n\n\u003cp\u003eThe 500A rating makes this shunt appropriate for battery banks and systems where peak charge or discharge currents can be substantial, such as large inverter installations, high-capacity lithium or AGM battery banks, and solar systems with significant load or charging current. Sizing the shunt correctly matters: running a shunt continuously above its rated current will cause measurement drift and potential damage, so confirm your system's maximum expected current before selecting this rating.\u003c\/p\u003e\n\n\u003cp\u003eThis shunt is the standard replacement or additional shunt supplied by Victron for use with their BMV-700, BMV-702, BMV-712 and SmartShunt product lines where a separate shunt is required. It connects via the dedicated shunt terminals on those monitors using the supplied cable harness from the monitor kit.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: SHU500050100\u003c\/li\u003e\n  \u003cli\u003eRated current: 500A\u003c\/li\u003e\n  \u003cli\u003eVoltage drop at rated current: 50mV\u003c\/li\u003e\n  \u003cli\u003eShunt resistance: 0.1 milliohms\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.3kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076026211\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBattery current monitoring in off-grid solar power systems.\u003c\/li\u003e\n  \u003cli\u003eCurrent sensing in marine and narrowboat 12V or 24V house battery banks.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and campervan leisure battery monitoring installations.\u003c\/li\u003e\n  \u003cli\u003eReplacement or spare shunt for Victron BMV battery monitor installations.\u003c\/li\u003e\n  \u003cli\u003eAny DC system requiring accurate current measurement up to 500A continuous.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron Energy 500A\/50mV shunt\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe shunt must be installed in the negative main cable between the battery bank negative terminal and the system negative busbar, with all loads and chargers connected on the system side. Only the battery negative should connect directly to the shunt battery terminal. Incorrect wiring will produce inaccurate readings. For systems forming part of a grid-connected or high-voltage installation, work should be carried out by a qualified electrician or MCS-accredited installer. Ensure all connections are torqued correctly and that the shunt is rated for the maximum continuous current in your system before installation.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59856061432142,"sku":"SHU500050100","price":17.56,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_SHU500050100_-_Shunt_500A-50mV.webp?v=1781102049"},{"product_id":"victron-anl-fuse-400a-80v-pack-of-5","title":"Victron ANL-fuse 400A\/80V (package of 5 pcs) - CIP143400020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy ANL Fuse 400A\/80V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy ANL fuse 400A\/80V is a high-current DC protection fuse designed for use in battery systems, inverter installations and other high-amperage DC circuits. Sold in a pack of five, it is suited to installers and system integrators who need reliable overcurrent protection across multiple installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e400A current rating provides overcurrent protection for high-capacity DC circuits.\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating is compatible with 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eANL form factor fits standard ANL fuseholders, including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, suitable for stocking or multi-system installations.\u003c\/li\u003e\n  \u003cli\u003eDesigned to protect wiring and equipment from fault currents in inverter and battery bank applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eANL fuses are a standard choice for DC overcurrent protection in battery-based systems. The blade-style ANL format allows for straightforward replacement and provides a visible, auditable point of protection in the DC circuit. At 400A, this fuse is appropriate for large inverter installations, battery banks and high-current DC distribution where cable and equipment protection is required.\u003c\/p\u003e\n\n\u003cp\u003eThe 80V voltage rating covers the full range of common battery system voltages, including 48V nominal systems which may reach higher voltages under charge. This fuse is compatible with Victron ANL fuseholders and other standard ANL holders available in the market. Buying in a pack of five reduces per-unit cost and ensures spares are on hand for commissioning or future servicing.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP143400020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 400A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: ANL\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.1 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061786\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection for Victron Multiplus, Quattro and other large inverter\/charger installations.\u003c\/li\u003e\n  \u003cli\u003eBattery bank protection in off-grid and backup power systems.\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards and busbars in marine, vehicle and static installations.\u003c\/li\u003e\n  \u003cli\u003eHigh-current DC circuits in commercial and industrial energy storage systems.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing ANL fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy ANL fuse 400A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eANL fuses should be installed by a qualified electrician or experienced system integrator familiar with high-current DC installations. Ensure the fuseholder is rated to match the fuse current and voltage before installation. Disconnect all power sources before replacing a fuse. In battery systems, take care to isolate the battery bank fully, as DC fault currents can be extremely high and present a serious risk of arc flash or fire if handled incorrectly.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863661707598,"sku":"CIP143400020","price":25.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP143400020_-_ANL-fuse_400A-80V_package_of_5_pcs.webp?v=1781183050"},{"product_id":"victron-anl-fuse-500a-80v-pack-of-5","title":"Victron ANL-fuse 500A\/80V (package of 5 pcs) - CIP143500020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy ANL Fuse 500A\/80V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy ANL fuse 500A\/80V is a high-current DC protection fuse designed for use in battery systems, inverter installations and other high-amperage DC circuits. Sold in a pack of five, it is suited to installers and system integrators who need reliable overcurrent protection across multiple installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e500A continuous current rating for high-capacity DC circuits\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating, compatible with 12V, 24V and 48V battery systems\u003c\/li\u003e\n  \u003cli\u003eANL format fuse, designed for use with standard ANL fuseholders\u003c\/li\u003e\n  \u003cli\u003eProvides overcurrent and short-circuit protection for inverters, battery banks and DC distribution\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, suitable for trade, installer and multi-system use\u003c\/li\u003e\n  \u003cli\u003eVictron Energy part number CIP143500020, GTIN 8719076061793\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eANL fuses are a standard format for high-current DC protection in battery-based energy systems. The blade-style construction allows for straightforward installation into a compatible ANL fuseholder, providing a clear and serviceable point of overcurrent protection between the battery bank and the load or inverter.\u003c\/p\u003e\n\n\u003cp\u003eAt 500A, this fuse is appropriate for large inverter installations, high-capacity battery banks and DC busbars where fault currents could otherwise cause significant damage. The 80V rating covers the full range of common battery voltages used in off-grid, marine and vehicle installations, including 48V systems operating at elevated charge voltages. Always match the fuse rating to the cable and system design rather than simply the inverter's nominal current draw.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCurrent rating: 500A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: ANL\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.1 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eSKU: CIP143500020\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061793\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on inverter DC input cables in off-grid and hybrid solar systems\u003c\/li\u003e\n  \u003cli\u003eBattery bank protection in 12V, 24V and 48V installations\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards and busbars in marine and motorhome electrical systems\u003c\/li\u003e\n  \u003cli\u003eProtection of high-current DC wiring in commercial vehicle and industrial battery systems\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing ANL fuseholder installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy ANL fuse 500A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eANL fuses must be installed in a compatible ANL fuseholder rated for the voltage and current of the circuit. Fuses should be positioned as close to the battery positive terminal as practicable to maximise protection of the wiring. Ensure the fuseholder connections are clean and torqued to the manufacturer's specification to prevent resistance heating at the contact points. High-current DC systems carry significant fault energy and installation should be carried out by a qualified electrician or accredited installer familiar with DC battery systems.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863661773134,"sku":"CIP143500020","price":25.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP143500020_-_ANL-fuse_500A-80V_package_of_5_pcs.webp?v=1781183054"},{"product_id":"victron-dual-terminal-stud-m8-linked-set","title":"Victron Dual Terminal Stud M8-linked set (1 red\/1 black) - VBB413020010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eDual Terminal Stud M8 Linked Set (1 Red \/ 1 Black)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Dual Terminal Stud M8 Linked Set provides a paired positive and negative M8 stud terminal solution for busbar and battery connection work. Supplied as a matched red and black pair with an internal link, it is suited to professional DC wiring installations where clean, secure dual-pole termination is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupplied as a linked pair: one red (positive) and one black (negative) terminal stud.\u003c\/li\u003e\n  \u003cli\u003eM8 stud size, compatible with standard M8 ring terminals and busbars.\u003c\/li\u003e\n  \u003cli\u003eInternal link connects the two terminals, simplifying dual-pole wiring layouts.\u003c\/li\u003e\n  \u003cli\u003eColour-coded housings aid correct polarity identification during installation.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 131 g, suitable for panel builds and enclosure work.\u003c\/li\u003e\n  \u003cli\u003eGenuine Victron Energy component, SKU VBB413020010.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThis linked stud set is designed for use in DC distribution panels, busbar assemblies and battery connection points where both positive and negative terminations are needed in close proximity. The internal link between the two studs allows current to be distributed across multiple connection points without additional bridging hardware.\u003c\/p\u003e\n\n\u003cp\u003eM8 is a widely used stud size in 12 V, 24 V and 48 V DC systems, accepting a broad range of ring terminals and cable lugs. The colour-coded red and black housings reduce the risk of polarity errors during assembly, which is particularly useful in complex wiring environments with multiple conductors.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: VBB413020010\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076052241\u003c\/li\u003e\n  \u003cli\u003eStud size: M8\u003c\/li\u003e\n  \u003cli\u003eConfiguration: Linked pair (1 red \/ 1 black)\u003c\/li\u003e\n  \u003cli\u003eWeight: 131 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC busbar assemblies in off-grid and marine electrical panels.\u003c\/li\u003e\n  \u003cli\u003eBattery positive and negative distribution points in 12 V, 24 V and 48 V systems.\u003c\/li\u003e\n  \u003cli\u003eMotorhome, caravan and van conversion wiring builds.\u003c\/li\u003e\n  \u003cli\u003eEnclosure and cabinet wiring where dual-pole stud termination is required.\u003c\/li\u003e\n  \u003cli\u003eReplacement or expansion of existing Victron busbar installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Red M8 terminal stud\u003c\/li\u003e\n  \u003cli\u003e1 x Black M8 terminal stud\u003c\/li\u003e\n  \u003cli\u003eInternal link connecting the two terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThese terminal studs should be installed by a competent person with experience in DC electrical systems. Ensure all connections are torqued correctly to the M8 specification and that the system is isolated before fitting. For battery and inverter installations forming part of a larger solar or off-grid system, a qualified installer should carry out the work.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863679500622,"sku":"VBB413020010","price":15.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_VBB413020010_-_Dual_Terminal_Stud_M8-linked_set_1_red-1_black.webp?v=1781183328"},{"product_id":"victron-mega-fuse-500a-80v-pack-of-5","title":"Victron MEGA-fuse 500A\/80V (package of 5 pcs) - CIP138500020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy MEGA-Fuse 500A\/80V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 500A\/80V is a high-current DC fuse designed to protect battery cables, busbars and inverter connections in 12V, 24V and 48V systems. Sold in a pack of five, it is suited to installers and system builders who need reliable overcurrent protection across multiple installations or battery banks.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e500A continuous current rating for high-load DC applications including large inverters and battery systems.\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating, compatible with 12V, 24V and 48V battery banks.\u003c\/li\u003e\n  \u003cli\u003eMEGA fuse format, compatible with standard MEGA fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eSold in a pack of 5, reducing per-unit cost for trade and multi-installation use.\u003c\/li\u003e\n  \u003cli\u003eProvides short-circuit and overcurrent protection for main battery cables and DC distribution.\u003c\/li\u003e\n  \u003cli\u003eSKU: CIP138500020 | GTIN: 8719076061762 | Weight: 0.045 kg (pack).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses are a widely used format in automotive, marine and off-grid solar DC systems. The blade-style body fits into a dedicated MEGA fuseholder and provides a clear, serviceable point of overcurrent protection on the main positive cable between the battery and the load or inverter. At 500A, this fuse is rated for the highest-draw DC equipment, including large Victron Quattro and MultiPlus inverter\/chargers where cable protection at the battery terminals is required.\u003c\/p\u003e\n\n\u003cp\u003eThe 80V DC rating gives adequate headroom above nominal 48V battery voltages, including lithium systems that may reach 58V or above at full charge. This makes the fuse suitable across the full range of common battery chemistries and voltages used in off-grid, marine and vehicle installations. Using the correct fuse rating for the cable cross-section and connected equipment is essential: a 500A fuse should only be used where the cable and terminals are rated to carry that current continuously.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCurrent rating: 500A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eSKU: CIP138500020\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061762\u003c\/li\u003e\n  \u003cli\u003ePack weight: 0.045 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain battery cable protection on large off-grid solar systems with high-capacity inverters.\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection on 12V, 24V and 48V lithium and lead-acid battery banks.\u003c\/li\u003e\n  \u003cli\u003eMarine DC systems requiring high-current fusing on the main positive feed.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome conversions with large inverter or winch installations.\u003c\/li\u003e\n  \u003cli\u003eDC busbar protection in multi-battery or parallel battery configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 500A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses must be installed in a compatible MEGA fuseholder rated for the current and voltage of the application. Ensure the fuseholder, cable lugs and cable cross-section are all rated to carry 500A continuously before fitting this fuse. DC systems at these current levels carry significant energy and can cause fire or serious injury if incorrectly wired. Installation should be carried out by a qualified electrician or experienced system integrator familiar with DC battery systems. For grid-connected solar installations, work must comply with current UK wiring regulations and be carried out by a suitably qualified installer.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863695589710,"sku":"CIP138500020","price":28.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP138500020_-_MEGA-fuse_500A-80V_package_of_5_pcs.webp?v=1781183516"},{"product_id":"victron-midi-fuse-30a-58v-m6-pack-of-5","title":"Victron MIDI-fuse 30A\/58V-M6 (package of 5 pcs) - CIP134030020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MIDI Fuse 30A\/58V M6 (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThese are Victron Energy MIDI fuses rated at 30A and 58V, supplied in a pack of five. They are designed for use in DC protection circuits in solar, battery and inverter installations where a MIDI-format fuse is required. The M6 bolt connection suits standard MIDI fuseholders.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 30A continuous current with a 58V DC voltage rating, suitable for battery and solar DC circuits.\u003c\/li\u003e\n  \u003cli\u003eM6 bolt connection for secure, low-resistance termination in MIDI fuseholders.\u003c\/li\u003e\n  \u003cli\u003eMIDI form factor is widely used across Victron Energy and compatible third-party fuseholders.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a pack of five, providing spares for commissioning, maintenance or multi-circuit installations.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 15g per pack, with a GTIN of 8719076061533 for straightforward procurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses provide overcurrent protection in DC wiring between batteries, inverters, charge controllers and busbars. The 30A rating makes this fuse appropriate for protecting cables and equipment in lower-current DC circuits, such as individual loads or branch circuits within a larger system. The 58V rating covers 12V, 24V and 48V battery systems comfortably within its operating envelope.\u003c\/p\u003e\n\n\u003cp\u003eThe M6 bolt fixing ensures a firm mechanical and electrical connection within the fuseholder, reducing the risk of resistance build-up at the terminal over time. MIDI fuses are a common choice in professional DC installations because they offer a clear visual indication of a blown fuse and are straightforward to replace in the field. Having a pack of five on hand is practical for installers commissioning multiple circuits or carrying stock for service visits.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP134030020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 30A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 58V DC\u003c\/li\u003e\n  \u003cli\u003eConnection: M6 bolt\u003c\/li\u003e\n  \u003cli\u003eFormat: MIDI fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.015 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061533\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection in 12V, 24V and 48V DC battery systems.\u003c\/li\u003e\n  \u003cli\u003eBranch circuit fusing in off-grid solar installations.\u003c\/li\u003e\n  \u003cli\u003eProtection of DC wiring between Victron inverters, charge controllers and battery banks.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MIDI fuseholder installations.\u003c\/li\u003e\n  \u003cli\u003eSpare stock for solar installers and service engineers carrying out maintenance or fault-finding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron MIDI fuse 30A\/58V M6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure the fuseholder is rated for the voltage and current of the circuit before fitting. Always isolate the DC circuit before replacing a fuse. These fuses are rated for DC use only at 58V maximum; do not use them in circuits exceeding this voltage. Installation within battery and inverter systems should be carried out by a qualified electrician or accredited installer familiar with DC protection requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863696343374,"sku":"CIP134030020","price":9.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP134030020_-_MIDI-fuse_30A-58V-M6_package_of_5_pcs_c651d062-51d7-472a-ad07-4d8943fc3319.webp?v=1784900898"},{"product_id":"victron-midi-fuse-50a-58v-m6-pack-5","title":"Victron MIDI-fuse 50A\/58V-M6 (package of 5 pcs) - CIP134050020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MIDI Fuse 50A\/58V M6 (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MIDI-fuse 50A\/58V with M6 bolt connection is a blade-style fuse rated for 58V DC systems, supplied in a pack of five. It is designed for use in DC protection circuits on solar, battery and inverter installations where a compact, reliable fuse is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e50A current rating suitable for DC circuit protection in battery and solar systems.\u003c\/li\u003e\n  \u003cli\u003e58V voltage rating covers typical 12V, 24V and 48V DC system voltages.\u003c\/li\u003e\n  \u003cli\u003eM6 bolt terminal connection for a secure, low-resistance contact.\u003c\/li\u003e\n  \u003cli\u003eMIDI blade fuse format, compatible with standard MIDI fuseholders.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a pack of 5, providing spares for commissioning and maintenance.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 15g per pack, with a compact form factor suited to tight enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses are a common choice for DC overcurrent protection in off-grid and battery-based systems. The 50A rating makes this fuse appropriate for protecting cables and equipment on 12V, 24V or 48V battery banks, inverter inputs, and DC distribution circuits where fault currents need to be interrupted quickly and safely.\u003c\/p\u003e\n\n\u003cp\u003eThe M6 bolt terminal ensures a firm mechanical connection that resists vibration and thermal cycling, which is important in mobile and marine installations as well as fixed off-grid setups. The 58V DC voltage rating is sufficient for fully charged 48V lithium and lead-acid battery systems. Using a correctly rated fuse in the right fuseholder is essential for maintaining circuit integrity and meeting installation safety requirements.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP134050020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 50A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 58V DC\u003c\/li\u003e\n  \u003cli\u003eTerminal type: M6 bolt\u003c\/li\u003e\n  \u003cli\u003eFuse format: MIDI blade\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.015 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061557\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC overcurrent protection on 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eInverter input cable protection in off-grid and hybrid solar installations.\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards and busbar protection in marine and motorhome builds.\u003c\/li\u003e\n  \u003cli\u003eBattery-to-charge-controller wiring protection in solar PV systems.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MIDI fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron MIDI-fuse 50A\/58V M6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThese fuses must be installed in a compatible MIDI fuseholder rated for the same voltage and current. Ensure the M6 bolt terminals are torqued to the fuseholder manufacturer's specification to avoid loose connections. DC fusing should be sized to protect the cable, not just the load. For battery and inverter installations, qualified electrical installation is recommended. Always isolate the battery before replacing fuses.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863696933198,"sku":"CIP134050020","price":9.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP134050020_-_MIDI-fuse_50A-58V-M6_package_of_5_pcs.webp?v=1781183523"},{"product_id":"victron-midi-fuse-80a-58v-m6-pack-5","title":"Victron MIDI-fuse 80A\/58V-M6 (package of 5 pcs) - CIP134080020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MIDI Fuse 80A\/58V M6 (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MIDI fuse 80A\/58V with M6 bolt connection is a blade-style DC fuse designed for use in battery and solar systems where reliable overcurrent protection is required. Sold in packs of five, these fuses are suited to installers and system builders working with 12V, 24V and 48V DC installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e80A current rating with a 58V DC voltage rating, suitable for 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eM6 bolt terminal connection for a secure, low-resistance contact in fuseholder applications.\u003c\/li\u003e\n  \u003cli\u003eMIDI fuse format, compatible with standard MIDI fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eSold as a pack of 5, making them practical for multi-circuit installations or stocking spares.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 15g per pack, with minimal installation footprint in DC distribution boards and cable runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses are a widely used format in DC electrical systems, particularly in marine, off-grid, vehicle and battery storage installations. The M6 bolt connection provides a firm mechanical and electrical contact within a compatible MIDI fuseholder, reducing the risk of high-resistance joints that can cause nuisance tripping or heat build-up under load.\u003c\/p\u003e\n\n\u003cp\u003eThe 80A rating makes this fuse appropriate for protecting cable runs and equipment in mid-range DC circuits, such as battery-to-inverter connections, DC distribution feeds, or charge controller outputs in systems where the continuous current draw falls within this threshold. The 58V maximum voltage rating covers standard 48V nominal battery banks with headroom for charge voltages.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP134080020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 80A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 58V DC\u003c\/li\u003e\n  \u003cli\u003eTerminal type: M6 bolt\u003c\/li\u003e\n  \u003cli\u003eFuse format: MIDI\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.015 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061588\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on DC cable runs in 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eFuse replacement or stocking for installations using Victron MIDI fuseholders.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat DC distribution panels.\u003c\/li\u003e\n  \u003cli\u003eOff-grid solar systems with battery banks up to 48V nominal.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome leisure battery circuits.\u003c\/li\u003e\n  \u003cli\u003eBattery-to-inverter protection where an 80A fuse rating is specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron MIDI fuse 80A\/58V M6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses must be installed in a compatible MIDI fuseholder rated for the voltage and current of the circuit. Ensure the M6 bolt terminals are torqued to the fuseholder manufacturer's specification to maintain a reliable connection. Always size fuses to protect the cable, not the load. For DC systems connected to battery banks or solar arrays, installation should be carried out by a qualified electrician or experienced installer familiar with DC protection requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863697588558,"sku":"CIP134080020","price":9.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP134080020_-_MIDI-fuse_80A-58V-M6_package_of_5_pcs.webp?v=1781183527"},{"product_id":"victron-anl-fuse-300a-80v-pack-of-5","title":"Victron ANL-fuse 300A\/80V (package of 5 pcs) - CIP143300020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy ANL Fuse 300A\/80V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy ANL fuse 300A\/80V is a high-current DC protection fuse designed for use in battery systems, inverter installations and other high-amperage DC circuits. Sold in a pack of five, it is suited to installers and system integrators who need reliable overcurrent protection across multiple installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e300A continuous current rating for high-capacity DC circuits.\u003c\/li\u003e\n  \u003cli\u003e80V DC voltage rating, compatible with 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eANL format fuse, designed for use with standard ANL fuseholders.\u003c\/li\u003e\n  \u003cli\u003eProvides overcurrent and short-circuit protection for inverters, battery banks and DC distribution systems.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a pack of 5, reducing per-unit cost for trade and multi-installation use.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 0.1 kg per pack, with compact form factor for straightforward installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eANL fuses are a standard format for high-current DC protection in marine, off-grid and automotive electrical systems. The blade-style construction allows for quick replacement and provides a clear visual indication of a blown fuse. At 300A, this fuse is appropriate for large inverter installations, battery-to-busbar connections and high-draw DC loads where cable and component protection is critical.\u003c\/p\u003e\n\n\u003cp\u003eThe 80V rating covers the full operating range of 12V, 24V and 48V nominal battery systems, including those with elevated charge voltages. This makes the fuse compatible with lithium and lead-acid battery banks commonly used alongside Victron inverter-chargers and MultiPlus systems. Always match the fuse rating to the cable cross-section and the maximum continuous current of the connected equipment.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP143300020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 300A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: ANL\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.1 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061779\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on inverter DC input cables in 12V, 24V and 48V systems.\u003c\/li\u003e\n  \u003cli\u003eBattery bank to busbar connections in off-grid and marine installations.\u003c\/li\u003e\n  \u003cli\u003eHigh-current DC distribution boards and fuse panels.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing ANL fuseholder installations.\u003c\/li\u003e\n  \u003cli\u003eCommercial and trade use where multiple systems are being commissioned.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy ANL fuse 300A\/80V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eANL fuses must be installed in a compatible ANL fuseholder. Ensure the fuseholder is rated for at least 300A and 80V DC before fitting. Fuses should be positioned as close as possible to the battery positive terminal to provide effective short-circuit protection. DC electrical work on battery systems and inverter installations should be carried out by a qualified electrician or accredited installer. Always isolate the battery before replacing or installing fuses.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59866747863374,"sku":"CIP143300020","price":25.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP143300020_-_ANL-fuse_300A-80V_package_of_5_pcs.webp?v=1781200238"},{"product_id":"victron-midi-fuse-100a-32v-pack-5","title":"Victron MIDI-fuse 100A\/32V (package of 5 pcs) - CIP132100010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy MIDI Fuse 100A 32V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MIDI fuse 100A 32V is a blade-style DC protection fuse designed for use in battery systems, inverter installations and other DC circuits requiring reliable overcurrent protection. Sold in a pack of five, it is suited to installers and system builders who need spares on hand or are wiring multiple circuits.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100A current rating suitable for high-current DC protection in battery and inverter circuits.\u003c\/li\u003e\n  \u003cli\u003e32V DC voltage rating, compatible with 12V and 24V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMIDI fuse format, designed for use with MIDI fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, providing spares for multi-circuit installations or ongoing maintenance stock.\u003c\/li\u003e\n  \u003cli\u003eCompact blade construction for straightforward replacement without specialist tooling.\u003c\/li\u003e\n  \u003cli\u003eVictron Energy part number CIP132100010, ensuring compatibility with Victron MIDI fuseholder accessories.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses are a standard format in DC electrical protection, commonly used between battery banks and inverters, charge controllers, or busbars. The 100A rating makes this fuse appropriate for circuits where sustained high current draw is expected, such as connections to Victron MultiPlus or Phoenix inverters on 12V or 24V systems. The 32V maximum voltage rating covers both 12V and 24V nominal battery systems with headroom for charging voltages.\u003c\/p\u003e\n\n\u003cp\u003eBuying in a pack of five reduces per-unit cost and ensures replacement fuses are available on site. MIDI fuses are not resettable and must be replaced after a fault event, so having spares readily available is practical for any installation. These fuses are intended for use in a compatible MIDI fuseholder, which is sold separately.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP132100010\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 100A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 32V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MIDI blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.011 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076036500\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on 12V or 24V inverter input cables.\u003c\/li\u003e\n  \u003cli\u003eBattery bank to busbar connections in off-grid and marine systems.\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in motorhome, caravan and boat electrical installations.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MIDI fuseholder installations.\u003c\/li\u003e\n  \u003cli\u003eMulti-circuit DC distribution boards requiring individual circuit fusing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MIDI fuse 100A 32V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThese fuses must be installed in a compatible MIDI fuseholder rated for the application voltage and current. Ensure the fuseholder is correctly rated for DC use. DC fusing is not interchangeable with AC fusing. For inverter and battery system installations, a qualified electrician or accredited installer should carry out the work. Always isolate the battery before replacing a fuse.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59866753990990,"sku":"CIP132100010","price":7.64,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP132100010_-_MIDI-fuse_100A-32V_package_of_5_pcs.webp?v=1781200383"},{"product_id":"victron-midi-fuse-60a-58v-m6-pack-5","title":"Victron MIDI-fuse 60A\/58V-M6 (package of 5 pcs) - CIP134060020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MIDI Fuse 60A\/58V M6 (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MIDI fuse 60A\/58V with M6 bolt connection is a blade-style DC protection fuse designed for use in battery systems, inverter installations and other DC distribution applications. Sold in a pack of five, it is suited to installers and system builders who need reliable overcurrent protection across multiple circuits or projects.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e60A current rating with a 58V DC voltage rating, suitable for 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eM6 bolt terminal connection provides a secure, low-resistance contact point.\u003c\/li\u003e\n  \u003cli\u003eMIDI form factor is compatible with standard MIDI fuseholders, including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, practical for installers carrying spares or wiring multiple circuits.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 15g per pack, with minimal footprint for storage and transport.\u003c\/li\u003e\n  \u003cli\u003eSKU CIP134060020, GTIN 8719076061564 for straightforward ordering and stock management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses are a widely used format in DC electrical systems, particularly in marine, off-grid solar and vehicle installations. The bolt-down M6 terminal design ensures a firm mechanical and electrical connection within a compatible fuseholder, reducing the risk of intermittent contact or heat build-up at the terminal.\u003c\/p\u003e\n\n\u003cp\u003eThe 60A rating makes this fuse appropriate for protecting cables and equipment on circuits drawing up to 60 amps at voltages up to 58V DC. This covers the majority of 12V, 24V and 48V battery bank configurations used in solar storage and off-grid systems. Selecting the correct fuse rating for the cable cross-section and load is essential: this fuse should be matched to the cable it protects, not simply to the maximum load current.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCurrent rating: 60A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 58V DC\u003c\/li\u003e\n  \u003cli\u003eTerminal type: M6 bolt\u003c\/li\u003e\n  \u003cli\u003eFuse format: MIDI\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.015 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eSKU: CIP134060020\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061564\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on DC cables in off-grid solar and battery storage systems.\u003c\/li\u003e\n  \u003cli\u003eFuse replacement or spares stock for marine electrical installations.\u003c\/li\u003e\n  \u003cli\u003eProtection of inverter input cables in 12V, 24V or 48V systems.\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards and busbar protection in motorhome and vehicle conversions.\u003c\/li\u003e\n  \u003cli\u003eMulti-circuit installations where several fused connections are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron MIDI fuse 60A\/58V M6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses must be installed in a compatible MIDI fuseholder rated for the voltage and current of the circuit. Ensure the M6 bolt is torqued to the fuseholder manufacturer's specification to maintain a reliable connection. DC electrical work on battery and inverter systems carries risk of arc flash and short circuit. Installation should be carried out by a qualified electrician or experienced installer. For solar PV and battery storage systems in the UK, use of an MCS-accredited installer is recommended where applicable.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59866754056526,"sku":"CIP134060020","price":9.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP134060020_-_MIDI-fuse_60A-58V-M6_package_of_5_pcs.webp?v=1781200387"},{"product_id":"victron-shunt-2000a-50mv-3xm10","title":"Victron Shunt 2000A\/50mV-0,5 \/ 3xM10 - SHU202050200","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Shunt 2000A\/50mV (3xM10)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 2000A\/50mV shunt is a high-current DC measuring shunt designed for use in large battery systems, off-grid installations and commercial energy storage applications. It allows accurate current measurement by producing a calibrated 50mV signal at full rated current, which can be fed into a battery monitor or energy management system. The three M10 connection points accommodate heavy-gauge cabling suited to high-amperage DC circuits.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 2000A continuous DC current with a 50mV full-scale output signal, giving a shunt resistance of 0.025 milliohms.\u003c\/li\u003e\n  \u003cli\u003eThree M10 bolt terminals provide secure, low-resistance connections for large cross-section cables.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron BMV battery monitors and other shunt-based monitoring equipment that accept a 50mV input.\u003c\/li\u003e\n  \u003cli\u003eSolid construction with a weight of 2.15kg, reflecting the heavy-duty busbar and resistive element required at this current rating.\u003c\/li\u003e\n  \u003cli\u003eSuitable for use in battery banks, DC distribution boards and large inverter or motor drive installations where accurate current measurement is essential.\u003c\/li\u003e\n  \u003cli\u003eSKU: SHU202050200 | GTIN: 8719076026204\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA shunt works by inserting a known, very low resistance into the DC circuit. The voltage drop across that resistance is directly proportional to the current flowing through it. At 2000A, this shunt produces exactly 50mV, which is the standard signal level accepted by most battery monitors and data loggers. The measurement is passive and does not require a separate power supply, making it straightforward to integrate into existing monitoring wiring.\u003c\/p\u003e\n\n\u003cp\u003eAt 2000A, cable sizing, terminal torque and busbar layout all become critical. The three M10 terminals allow the load and source cables to be distributed across multiple connection points, reducing localised heating and mechanical stress on any single terminal. This is particularly relevant in systems where multiple battery strings or inverters share a common measurement point. The shunt should be positioned as close to the battery negative terminal as practical to capture all current flows in the circuit.\u003c\/p\u003e\n\n\u003cp\u003eThe 50mV output is a widely adopted standard. If you are using a Victron BMV-700, BMV-712 or SmartShunt, this external shunt allows you to extend measurement capability beyond the built-in 500A shunt supplied with those monitors, covering large-scale systems that would otherwise exceed the internal shunt's rating.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated current: 2000A DC\u003c\/li\u003e\n  \u003cli\u003eFull-scale voltage output: 50mV\u003c\/li\u003e\n  \u003cli\u003eTerminal size: 3x M10\u003c\/li\u003e\n  \u003cli\u003eWeight: 2.15kg\u003c\/li\u003e\n  \u003cli\u003eSKU: SHU202050200\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076026204\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge off-grid battery banks with multiple strings in parallel requiring a single high-current measurement point.\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial energy storage systems where total DC current exceeds the capacity of a standard integrated shunt.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle installations with high-capacity lithium or lead-acid battery systems.\u003c\/li\u003e\n  \u003cli\u003eDC distribution boards in large solar PV systems feeding multiple inverters or loads.\u003c\/li\u003e\n  \u003cli\u003eRetrofit current monitoring on existing installations where no shunt is currently fitted.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron Energy 2000A\/50mV shunt with 3xM10 terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis shunt carries the full DC current of the system and must be installed by a qualified electrician or experienced DC systems installer. At 2000A, incorrect cable sizing, inadequate terminal torque or poor busbar connections present a serious risk of overheating or fire. The shunt should be mounted on a non-conductive surface or properly insulated busbar assembly. Ensure all connections are made with appropriately rated lugs and that the 50mV sense wiring is routed separately from power cables to avoid interference. For systems connected to the grid, all relevant UK wiring regulations (BS 7671) apply.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":60190998495566,"sku":"SHU202050200","price":83.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_SHU202050200_-_Shunt_2000A-50mV-0_5_-_3xM10.webp?v=1784715817"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/collections\/Victron_Energy_Logo_svg_2c48e831-246d-44d1-9218-ce78290a9fc3.png?v=1781011814","url":"https:\/\/voltaconsolar.com\/collections\/victron-electrical.oembed?page=3","provider":"VoltaconSolar","version":"1.0","type":"link"}