Elios 3000W Solar Grid Tie Inverter
Elios Solar Grid Tie Inverter G100 Compliant
- Install more on small grid connections without under sizing the inverter thus maintaining optimum generation.
- Revisit existing solar installations to add more solar.
Voltacon offers an export limitation option integrated into the Elios nverter firmware. With the Energy Meter with Modbus Connection, and appropriate CT clamps, this dynamically adjusts PV power production. Allowing you to use more energy for self-consumption when the loads are high, while maintaining the export limit when the loads are low.
Systems with moderate daytime energy use may have little to no effect on energy generation whilst keeping the DNO's export limits satisfied.
Export Limitation Benefits
- Highly competitive cost grid limiting device
- Set any limit imposed by the DNO
- Enables larger installations
- Fast response time — follows rapid power changes (<1 sec)
- Fail-safe operation protects the grid
MODEL |
PH50-3000 |
PH50-3600M |
PH50-4200M |
PH50-5000M |
PH50-6000M |
|
RATED POWER(W) |
3000 |
3600 |
4200 |
5000 |
6000 |
|
PV INPUT(DC) |
Maximum recommended DC power(W) |
3450 |
4100 |
4800 |
5750 |
7000 |
Nominal DC operating voltage(V) |
360 |
|||||
Maximum DC voltage(V) |
550 |
|||||
Start voltage(V) |
100 |
|||||
MPPT voltage range(V) |
80~550 |
|||||
Maximum input current(A) |
11 |
11/11 |
11/11 |
11/11 |
11/11 |
|
No.of MPP tracker |
1 |
2 |
||||
Strings per MPP tracker |
1 |
|||||
GRID OUTPUT(AC) |
Nominal AC output power(W) |
3000 |
3600 |
4200 |
5000 |
6000 |
Maximum AC output power(VA) |
3000 |
3600 |
4200 |
5000 |
6000 |
|
Nominal output voltage(V);range(V) |
220/230/240;180-280 |
|||||
AC grid frequency(Hz);range(Hz) |
50/60;45~55/55-65 |
|||||
Nominal output current(A) |
13 |
15.7 |
18.3 |
21.8 |
26.1 |
|
Maximum output current(A) |
13.7 |
16.4 |
19.1 |
22.8 |
27.3 |
|
Total harmonic distortion i(THDi) |
<3% |
|||||
Power factor at rated power |
1 |
|||||
Displacement power factor |
0.8leading ~ 0.8lagging |
|||||
AC connection |
Single phase |
|||||
EFFICIENCY |
Maximum efficiency |
97.2% |
97.4% |
97.4% |
97.4% |
97.4% |
Euro-efficiency |
96.8% |
97.0% |
97.0% |
97.0% |
97.0% |
|
MPPT efficiency |
99.5% |
|||||
Self-Consumption night(W) |
<1 |
|||||
PROTECTION DEVICES |
DC reverse polarity protection |
Yes |
||||
DC switch rating for each MPPT |
Yes(opt.) |
|||||
Output over current protection |
Yes |
|||||
Output overvoltage protection-varistor |
Yes |
|||||
Ground fault monitoring |
Yes |
|||||
Grid monitoring |
Yes |
|||||
Integrated all-pole sensitive leakage current |
Yes |
|||||
PHYSICAL |
Dimension(W/H/D)(mm) |
262*368*155 |
355*412*153 |
355*412*153 |
355*412*173 |
355*412*201 |
Net weight (kg) |
10 |
13.5 |
13.5 |
14.5 |
16.5 |
|
INTERFACE |
DC connection |
H4/MC4 |
||||
AC connection |
Connector |
|||||
Display |
LED |
|||||
Communication interfaces |
Wi-Fi/USB/GPRS |
|||||
ENVIRONMENT |
Ingress protection rating |
IP65 |
||||
Humidity |
0~95% RH (No condensing) |
|||||
Operating temperature range |
-25℃ ~+60℃ With derating above 45℃ |
|||||
Cooling concept |
Natural |
|||||
Noise emission(typical)[dB] |
≤25 |
|||||
Altitude |
<4000m |
|||||
OTHERS |
Topology |
transformerless |
||||
Warranty |
Standard 5years/10 years(opt.) |
|||||
Certificatesand approvals |
CE/IEC62109 |
CE / IEC62109 / CQC |