Clearance / Ex-Display Units - Click here 
NOTICE: Pylontech New Stock with Lower Price Expected End of May 2023
  • Global Delivery Available
  • Solar Experts Since 2002
  • 5 Year Extended Warranty

Voltasol Hybrid ESS 5500Watt Inverter / Charger For Pylontech Lithium Ion Batteries 48V

Rating:
0% of 100

Hybrid grid-tied, off-grid or simple grid feed in function, the new Voltasol is fully equipped with energy meter, BMS communication, and colours touch screen.

£1,490.00 Incl VAT.
<
>
Accepted Payment Methods
Single-Phase Hybrid Inverters

5.5kW Hybrid Grid-Tie and Off-Grid Inverter AC Charger & Solar MPPT

What does ESS mean?

ESS is a special solar power system with energy storage that is integrated to the power grid with Voltacon hybrid inverters and lithium batteries. Energy is stored in batteries during the day (or at night with economy rate) for use later when the sun is not available. 

It also allows for programming and prioritizing the power source (grid, solar, battery) , charging from solar, and feeding back to the grid. The latter function is adjustable, if there is no need to export energy the users will set the export value to 0Watt.

The ESS 5.5kW will automatically export surplus energy (or it will stop production if there is no energy demand and the batteries are fully charged). When the energy from the batteries and solar in insufficient, it will automatically buy power from the grid. 

Operating modes

  1. Off-grid but with the grid as a back 
  2. Hybrid mode works with the grid in parallel, the inverter and grid will feed the AC loads.
  3. It exports energy back to the grid but this is adjustable from 0Watt to 5500Watt
  4. It can supply the AC loads connected to the grid and critical loads off-grid, combined capacity 5.5kW
  5. Timer Chargers. The ac charger is available for charging from the utility on demand when the tariff is cheaper

Product Features

  • Pure sine wave output
  • Self-consumption and Feed-back to the Grid
  • Programmable supply priority for PV, battery or Grid
  • User-adjustable battery charging current
  • Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
  • Built-in timer for various modes of on/off operation
  • Multiple communication for USB, RS232, Modbus, SNMP, GPRS and Wi-Fi
  • Monitoring software for real-time status display and control
  • Enhance AC/Solar charger to 100A
  • Scalable Li-Ion battery expansion
  • BMS is Compatible with US2000C, US3000C, US5000 including the old versions

The inverter is delivered with the following accessories

- Energy meter and Modbus for communication.

- Pre-installed cards for BMS and energy meter connection.

- Wi-Fi module for wireless communication over the internet

- BMS RJ45 cable 

- Communication cable with an extension between the energy meter and card.

MODEL ESS 5.5KW
Maximum PV Input Power 6500 W
Rated Output Power 5500 W
Maximum Charging Power 2880 W
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 360 VDC / 500 VDC
Start-up Voltage / Initial Feeding Voltage 116 VDC / 150 VDC
MPP Voltage Range 120 VDC ~ 450 VDC
Number of MPP Trackers / Maximum Input Current   2 / 2 x 13 A 
GRID OUTPUT
Nominal Output Voltage 208/220/230/240 VAC
Output Voltage Range 184 - 264.5 VAC*
Max. Output Current 23.9A*
Maximum Conversion Efficiency (DC/AC) 96%
European Efficiency @ Vnominal 95%
AC INPUT
AC Start-up Voltage / Auto Restart Voltage 120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range  170 -280 VAC 
Maximum AC Input Current  40 A 
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 208/220/230/240 VAC
Maximum Conversion Efficiency (DC/AC) 93%
BATTERY & CHARGER
Nominal DC Voltage 48 VDC
Maximum Charging Current 100 A
PHYSICAL
Dimension, D X W X H (mm) 214 x 621 x 500 
Net Weight (kgs) 25
STANDARD
Compliance Safety IEC/EN 62109-1/-2, IEC 62040-1, EN 61000-6-4, EN IEC 61000-6-2, EN IEC 61000-3-11, EN 61000-3-12, IEC 61727, IEC 62116, G99, NRS 097-2-1,
EN 50549-1
BATTERY MODULE  ESS II-4810
CAPACITY 5120Wh
PARAMETERS
Norminal Voltage 51.2VDC
Full Charge Voltage(FC) 56V
Full Discharge Voltage(FD) 42V
Typical Capacity 100 Ah
Max Continuous Discharging Current 150A
Max Discharging Current 192A at 1min
Protecttion BMS, breaker
Charge Voltage 56V
Charge Current  20A (0.2C)
Maximum Charge current 50A (0.5C)
Standard Charge method 0.2C CC (Constant current) charge to FC,
CV (Contstant voltage FC) charge till charge current decline to <0.05C
Inner Resistance ≤20m ohm
PHYSICAL
Dimension, D X W X H (mm) 214 x 621 x 550
Net Weight (kgs) 50
STANDARD
Compliance Safety IEC 62619, EN 61000-6-3, EN 61000-6-1, UKCA, UN38.3
Write a review: