{"product_id":"victron-bluesolar-mppt-150-70-mc4","title":"Victron BlueSolar MPPT 150\/70-MC4 - SCC010070300","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron BlueSolar MPPT 150\/70-MC4 Solar Charge Controller\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron BlueSolar MPPT 150\/70-MC4 is a solar charge controller designed for professional off-grid and battery-based solar installations. It accepts a maximum PV open-circuit voltage of 150V and delivers up to 70A of charge current, with integrated MC4 connectors for direct panel string connection. Suited to installers working on larger residential, commercial or off-grid systems where a high-current MPPT controller is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaximum PV input voltage of 150V, suitable for series-connected panel strings.\u003c\/li\u003e\n  \u003cli\u003e70A maximum charge current, supporting substantial battery bank charging from solar.\u003c\/li\u003e\n  \u003cli\u003eIntegrated MC4 connectors on the PV input, eliminating the need for separate MC4 adapters at the controller.\u003c\/li\u003e\n  \u003cli\u003eMulti-stage adaptive charging algorithm supports lead-acid (AGM, gel, flooded) and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003eVictron MPPT tracking algorithm responds rapidly to changing irradiance conditions, maximising energy harvest throughout the day.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VE.Direct communications port for monitoring via the Victron Connect app or integration with a GX device.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Bluetooth is not included on this model; a VE.Direct Bluetooth Smart dongle can be added separately for wireless monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe BlueSolar MPPT 150\/70-MC4 sits within Victron's BlueSolar range, which does not include built-in Bluetooth (unlike the SmartSolar series). This makes it a cost-effective choice where monitoring is handled through a GX device such as a Cerbo GX, or where a wired VE.Direct connection to a display or data logger is preferred. The 150V maximum PV voltage allows for meaningful string lengths, reducing wiring runs and associated losses on larger arrays.\u003c\/p\u003e\n\n\u003cp\u003eThe 70A output is capable of charging 12V, 24V and 48V battery banks, with the controller automatically detecting the system voltage on first connection. At 48V, the 70A output equates to a maximum charge power of around 3,360W, making this unit appropriate for mid-to-large off-grid systems. The integrated MC4 connectors on the solar input are a practical feature on installations where the PV cabling terminates in MC4 plugs, as is standard with most modern solar panels.\u003c\/p\u003e\n\n\u003cp\u003eVictron's MPPT algorithm continuously tracks the maximum power point of the connected array. In conditions of partial shading or fluctuating irradiance, this results in measurably better energy yield compared to PWM controllers. The multi-stage charging profile (bulk, absorption, float, and optional equalisation for lead-acid) is configurable via VE.Direct-connected tools, allowing the charge parameters to be matched to the specific battery chemistry and manufacturer recommendations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSCC010070300\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMaximum PV Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e150V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMaximum Charge Current\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e70A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCompatible Battery Voltages\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12V, 24V, 48V (auto-detect)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePV Connector Type\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMC4 (integrated)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunications\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Direct\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3.88 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076025528\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential systems with 12V, 24V or 48V battery banks.\u003c\/li\u003e\n  \u003cli\u003eRemote commercial installations where wired monitoring via a GX device is already in place.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle applications requiring a high-current MPPT controller with a 150V PV input.\u003c\/li\u003e\n  \u003cli\u003eAgricultural and rural off-grid setups with larger panel arrays connected via MC4 cabling.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems where solar charging is integrated into an existing Victron system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron BlueSolar MPPT 150\/70-MC4 charge controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation should be carried out by a qualified electrician or accredited solar installer. The PV input can reach 150V open-circuit, which is a shock and arc-flash hazard and must be handled accordingly. Ensure the battery bank voltage is confirmed before connection, as the controller auto-detects system voltage on first use. For integration into a monitored Victron system, a VE.Direct cable or compatible GX device is required separately. Bluetooth monitoring requires the addition of a VE.Direct Bluetooth Smart dongle, which is not included. For any grid-connected elements of the wider system, G98 or G99 compliance requirements apply and should be confirmed with your DNO.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":60190722883918,"sku":"SCC010070300","price":287.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_SCC010070300_-_BlueSolar_MPPT_150-70-MC4.webp?v=1784713276","url":"https:\/\/voltaconsolar.com\/products\/victron-bluesolar-mppt-150-70-mc4","provider":"VoltaconSolar","version":"1.0","type":"link"}