{"product_id":"victron-bmv-710h-smart-battery-monitor","title":"Victron Battery Monitor BMV-710H Smart - BAM030710100","description":"\u003ch1 style=\"color: #f87c24;\"\u003eBattery Monitor BMV-710H Smart\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron BMV-710H Smart is a high-precision battery monitor designed for systems operating at higher voltages, up to 400V DC. It is suited to professional installers and off-grid system designers working with high-voltage battery banks, including lithium and lead-acid configurations. The BMV-710H tracks state of charge, voltage, current and consumed amp-hours with accuracy that basic voltmeters cannot match.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMeasures battery voltage up to 400V DC, making it compatible with high-voltage battery systems beyond the range of standard BMV monitors.\u003c\/li\u003e\n  \u003cli\u003eDisplays state of charge (%), voltage, current, power, consumed amp-hours (Ah) and time remaining.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Bluetooth via the VictronConnect app for wireless configuration, monitoring and data logging on iOS and Android devices.\u003c\/li\u003e\n  \u003cli\u003eProgrammable relay output for alarms, load control or generator start signals based on configurable thresholds.\u003c\/li\u003e\n  \u003cli\u003e500A shunt included as standard; compatible with external shunts for higher current applications.\u003c\/li\u003e\n  \u003cli\u003eBacklit display with intuitive navigation across all monitored parameters.\u003c\/li\u003e\n  \u003cli\u003eStores historical data including deepest discharge, average discharge, total Ah drawn and number of charge cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe BMV-710H is the high-voltage variant of Victron's BMV-710 Smart monitor. Where the standard 710 is rated to 95V, the 710H extends this to 400V DC, which is essential for series-connected battery banks or high-voltage DC bus systems. This makes it appropriate for larger off-grid installations, industrial backup systems and certain EV or marine applications where battery strings operate well above 48V.\u003c\/p\u003e\n\n\u003cp\u003eAccurate state of charge monitoring depends on precise current measurement over time. The BMV-710H uses a 500A shunt and a high-resolution current measurement circuit to calculate consumed amp-hours continuously. The Peukert exponent and charge efficiency factor are both configurable, allowing the monitor to be tuned to the actual behaviour of the battery chemistry in use, whether flooded lead-acid, AGM, gel or lithium.\u003c\/p\u003e\n\n\u003cp\u003eBluetooth connectivity is built in rather than added via a dongle. The VictronConnect app provides full access to settings, live data and historical logs without requiring a separate GX device. For installations integrated into a Victron system with a Cerbo GX or similar, the BMV-710H also communicates over VE.Direct.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBAM030710100\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery voltage range\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eUp to 400V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eShunt included\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e500A \/ 50mV\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBluetooth (built-in), VE.Direct\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eApp compatibility\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVictronConnect (iOS and Android)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eRelay output\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eProgrammable (alarm, load, generator start)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.74 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076049500\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-voltage off-grid battery banks where series-connected cells exceed 48V or 96V.\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial backup power systems with high-voltage DC bus configurations.\u003c\/li\u003e\n  \u003cli\u003eMarine installations with elevated battery string voltages.\u003c\/li\u003e\n  \u003cli\u003eMonitoring amp-hour consumption and state of charge in lithium battery systems requiring accurate Peukert compensation.\u003c\/li\u003e\n  \u003cli\u003eSystems integrated with Victron GX devices via VE.Direct for centralised monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBMV-710H Smart battery monitor unit with display\u003c\/li\u003e\n  \u003cli\u003e500A \/ 50mV shunt\u003c\/li\u003e\n  \u003cli\u003eConnection cables and hardware\u003c\/li\u003e\n  \u003cli\u003eVE.Direct cable (for GX device connection)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe BMV-710H operates at voltages up to 400V DC. Installation at these voltage levels carries a significant risk of electric shock and arc flash. This monitor must be installed by a qualified electrician or experienced off-grid systems installer. The shunt must be placed on the negative battery terminal with all loads and chargers connected on the load side of the shunt. Ensure the system is fully de-energised before making any connections. For systems integrated into grid-connected installations, consult your DNO and ensure compliance with applicable UK wiring regulations.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":60201621717326,"sku":"BAM030710100","price":433.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_BAM030710100_-_Battery_Monitor_BMV-710H_Smart_2.webp?v=1784816387","url":"https:\/\/voltaconsolar.com\/products\/victron-bmv-710h-smart-battery-monitor","provider":"VoltaconSolar","version":"1.0","type":"link"}