{"product_id":"victron-busbar-150a-4-pole-cover","title":"Victron Busbar 150A 4P +cover - VBB115040020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Busbar 150A 4-Pole with Cover — VBB115040020\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 150A 4-pole busbar is a compact distribution component for DC power systems. It provides a single, secure connection point for distributing current across up to four circuits, and is supplied with a protective cover. Suited to battery banks, inverter installations and off-grid DC distribution boards where a tidy, rated connection point is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 150A continuous DC current, suitable for high-current battery and inverter distribution applications.\u003c\/li\u003e\n  \u003cli\u003e4-pole design accommodates up to four separate circuit connections from a single busbar.\u003c\/li\u003e\n  \u003cli\u003eSupplied with a protective cover to guard against accidental contact and short circuits.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.17 kg, making it straightforward to mount within enclosures or distribution panels.\u003c\/li\u003e\n  \u003cli\u003eVictron Energy component, designed to integrate with Victron system builds and third-party DC installations alike.\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076052197 — genuine Victron part, traceable and verifiable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA busbar simplifies DC distribution by replacing multiple point-to-point cable runs with a single, rated connection rail. In a 4-pole configuration, one input (typically from a battery or main fuse) feeds up to four output circuits, each independently connected. This reduces wiring complexity and the number of terminals required at the battery or inverter.\u003c\/p\u003e\n\n\u003cp\u003eThe 150A rating means this busbar is appropriate for systems drawing significant continuous current, such as those built around Victron MultiPlus or Quattro inverter-chargers, or multi-battery bank setups. The included cover is not cosmetic: it reduces the risk of accidental short circuits during installation and in service, which is a genuine safety consideration in any live DC panel.\u003c\/p\u003e\n\n\u003cp\u003eAt 0.17 kg, this is a small but functional component. It is best mounted inside a suitable enclosure or distribution board rather than left exposed.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: VBB115040020\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 150A\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eCover included: Yes\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.17 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076052197\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDC distribution in off-grid solar systems with multiple load circuits.\u003c\/li\u003e\n  \u003cli\u003eBattery bank distribution points in van, motorhome and marine installations.\u003c\/li\u003e\n  \u003cli\u003eInverter and charger wiring consolidation in Victron system builds.\u003c\/li\u003e\n  \u003cli\u003eDistribution boards and enclosures requiring a compact, rated busbar with protective cover.\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial DC panel builds where circuit separation is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy 150A 4-pole busbar\u003c\/li\u003e\n  \u003cli\u003e1 x Protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis busbar should be installed by a qualified electrician or experienced system integrator. Ensure the busbar is correctly rated for the total current of all connected circuits combined, not just individual loads. Mount within a suitable enclosure to maintain the protection offered by the cover. Always isolate the battery or power source before making connections. For installations forming part of a grid-connected or solar PV system, work should be carried out by a qualified installer in accordance with BS 7671 and any applicable G98 or G99 requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":48288467190094,"sku":"VBB115040020","price":13.76,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-busbar-150a-4p-cover-vbb115040020-202645.jpg?v=1747945942","url":"https:\/\/voltaconsolar.com\/products\/victron-busbar-150a-4-pole-cover","provider":"VoltaconSolar","version":"1.0","type":"link"}