{"product_id":"victron-centaur-charger-24v-16a-3-output","title":"Victron Centaur Charger 24\/16(3) 120-240V - CCH024016000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Centaur Charger 24V\/16A (3 Outputs) 120-240V\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Centaur Charger 24\/16 is a three-output, mains-powered battery charger designed for professional marine, vehicle and off-grid applications. It delivers 16A of charge current at 24V across three independently managed battery banks, accepting a wide input voltage range of 120 to 240V AC for use in both UK and international installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16A charge current at 24V with three separate output channels for simultaneous multi-bank charging.\u003c\/li\u003e\n  \u003cli\u003eWide AC input range of 120 to 240V makes it suitable for UK, European and North American supply voltages.\u003c\/li\u003e\n  \u003cli\u003eFour-stage adaptive charging algorithm (bulk, absorption, float, storage) extends battery service life.\u003c\/li\u003e\n  \u003cli\u003eCompatible with gel, AGM, flooded lead-acid and calcium battery types via selectable charge profiles.\u003c\/li\u003e\n  \u003cli\u003eTemperature-compensated charging adjusts output voltage automatically to ambient conditions.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 4.3 kg, suitable for installation in confined spaces on vessels or vehicles.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in battery safe mode prevents deep discharge damage when connected to a battery under load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Centaur range uses an adaptive four-stage charge cycle. During bulk, the charger delivers full current until the battery reaches the absorption voltage. The absorption phase then holds voltage constant while current tapers, ensuring a full charge without overcharging. Float and storage modes maintain the battery at a safe resting voltage for long-term connection. This approach is particularly important in marine and vehicle environments where batteries may sit unused for extended periods.\u003c\/p\u003e\n\n\u003cp\u003eThree independent outputs allow the charger to service a main starter battery and one or two auxiliary banks simultaneously, each managed according to its own state of charge. This removes the need for separate chargers or manual switching between banks. The 120 to 240V input tolerance means the same unit can be used at a UK shore power connection, a European marina or a North American supply without modification.\u003c\/p\u003e\n\n\u003cp\u003eVictron's temperature compensation circuit monitors ambient temperature and adjusts the charge voltage accordingly. In cold conditions, a higher voltage is applied to ensure a full charge; in warm conditions, the voltage is reduced to prevent gassing and electrolyte loss. This is a practical benefit in installations where the charger is mounted in an engine bay or uninsulated compartment subject to wide temperature swings.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CCH024016000\u003c\/li\u003e\n  \u003cli\u003eOutput voltage: 24V\u003c\/li\u003e\n  \u003cli\u003eCharge current: 16A\u003c\/li\u003e\n  \u003cli\u003eNumber of outputs: 3\u003c\/li\u003e\n  \u003cli\u003eAC input voltage: 120 to 240V\u003c\/li\u003e\n  \u003cli\u003eWeight: 4.3 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076021544\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMarine vessels with separate starter, bow thruster and domestic battery banks.\u003c\/li\u003e\n  \u003cli\u003eMotorhomes and coaches requiring simultaneous charging of chassis and habitation batteries.\u003c\/li\u003e\n  \u003cli\u003eOff-grid cabins and site offices with shore power or generator supply.\u003c\/li\u003e\n  \u003cli\u003eCommercial vehicles with auxiliary battery systems for refrigeration or tail-lift equipment.\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring a single charger to service multiple 24V battery banks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Centaur Charger 24\/16 (3 outputs) unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation should be carried out by a qualified electrician or marine electrical engineer. The unit connects to a 120 to 240V AC mains supply and must be wired in accordance with local wiring regulations. In the UK, this means compliance with BS 7671 (IET Wiring Regulations). For marine installations, follow the relevant ISO or NMEA standards for on-board electrical systems. Ensure adequate ventilation around the unit and that DC output cabling is rated for the charge current. Battery type must be correctly selected via the charge profile settings before commissioning.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":60201799811406,"sku":"CCH024016000","price":346.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CCH024016000_-_Centaur_Charger_24-16_3_120-240V.webp?v=1784819079","url":"https:\/\/voltaconsolar.com\/products\/victron-centaur-charger-24v-16a-3-output","provider":"VoltaconSolar","version":"1.0","type":"link"}