{"product_id":"victron-energymeter-et112-single-phase-100a","title":"Victron EnergyMeter ET112 -1 phase-max 100A*Available until stock 0* - REL300100000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy EnergyMeter ET112 Single Phase 100A — REL300100000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron EnergyMeter ET112 is a single-phase energy meter designed to measure AC energy flow at up to 100A. It integrates directly with Victron GX devices to provide real-time monitoring of grid consumption, solar production or generator output. This product is available until current stock is exhausted and will not be restocked.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase AC energy measurement with a maximum current rating of 100A.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron GX devices (Cerbo GX, Color Control GX, Venus GX) for system-level monitoring.\u003c\/li\u003e\n  \u003cli\u003eMeasures bidirectional energy flow, making it suitable for grid import\/export monitoring as well as PV production metering.\u003c\/li\u003e\n  \u003cli\u003eCommunicates via RS-485 Modbus, connecting directly to the VE.Can or USB port on GX devices using a suitable interface.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.15 kg, designed for DIN rail mounting inside a consumer unit or distribution board.\u003c\/li\u003e\n  \u003cli\u003eDisplays real-time power, voltage, current and cumulative energy (kWh) data accessible through the Victron GX interface and VRM portal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ET112 is a single-phase variant in Victron's ET energy meter range. It connects to a GX device over RS-485 Modbus using a USB to RS-485 interface, and once configured it reports live power data to the GX device. This allows the GX device to make intelligent decisions about energy routing, such as adjusting inverter\/charger output based on actual grid import or export figures.\u003c\/p\u003e\n\n\u003cp\u003eIn a typical ESS (Energy Storage System) installation, the ET112 is placed at the grid connection point so the system can measure what is being drawn from or exported to the grid. It can also be used to monitor a PV inverter that is not natively compatible with Victron communication protocols. The 100A rating covers the majority of single-phase residential and light commercial connections in the UK.\u003c\/p\u003e\n\n\u003cp\u003eNote: this product is listed as available until stock reaches zero. It is a discontinued line and will not be replenished once sold out. Buyers should confirm availability before ordering.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eREL300100000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePhase configuration\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSingle phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMaximum current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication protocol\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eRS-485 Modbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDIN rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.15 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076039686\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAvailability\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDiscontinued — available until stock is exhausted\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrid import\/export monitoring in Victron ESS installations.\u003c\/li\u003e\n  \u003cli\u003ePV production metering for non-Victron solar inverters connected to a GX device.\u003c\/li\u003e\n  \u003cli\u003eGenerator output monitoring in off-grid and hybrid systems.\u003c\/li\u003e\n  \u003cli\u003eSingle-phase residential and light commercial energy monitoring via the VRM portal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron EnergyMeter ET112 single-phase energy meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ET112 must be installed by a qualified electrician. It is connected in-line with the AC supply at the measurement point and wired into the distribution board. Communication with the GX device requires a USB to RS-485 interface (not included). Ensure the GX device firmware is up to date to guarantee compatibility. As this is a discontinued product, verify stock availability before specifying it in a new installation design.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47442272584014,"sku":"REL300100000","price":36.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-energy-meter-et112-1-phase-max-100a-rel300100000-625239.jpg?v=1747937916","url":"https:\/\/voltaconsolar.com\/products\/victron-energymeter-et112-single-phase-100a","provider":"VoltaconSolar","version":"1.0","type":"link"}