{"product_id":"victron-inverter-12-800-230v-ve-direct-iec","title":"Victron Inverter 12\/800 230V VE.Direct IEC - PIN121801100","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Inverter 12\/800 230V VE.Direct IEC\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Inverter 12\/800 is a 12V DC to 230V AC pure sine wave inverter rated at 800VA continuous output. It is aimed at installers and professionals working on off-grid, mobile and backup power systems where a compact, reliable DC-to-AC conversion is required. The VE.Direct interface allows direct communication with compatible Victron monitoring equipment and displays.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e800VA continuous output power from a 12V DC battery bank to 230V AC\u003c\/li\u003e\n  \u003cli\u003ePure sine wave output suitable for sensitive electronics and motor loads\u003c\/li\u003e\n  \u003cli\u003eVE.Direct communication port for integration with Victron monitoring devices such as the Color Control GX and MPPT displays\u003c\/li\u003e\n  \u003cli\u003eIEC AC output socket for direct connection of standard IEC-compatible loads\u003c\/li\u003e\n  \u003cli\u003eProtections include low battery voltage shutdown, over-temperature and overload cutoff\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight design at 6 kg, suitable for installation in confined spaces\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron's VictronConnect app via a VE.Direct to USB or Bluetooth adapter for configuration and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Inverter 12\/800 converts 12V DC from a battery bank into a clean 230V AC pure sine wave output. Pure sine wave output is important when powering loads that are sensitive to waveform quality, including variable-speed motors, medical equipment, audio equipment and modern switch-mode power supplies. A modified sine wave inverter can cause overheating or malfunction in these devices; the 12\/800 avoids that risk entirely.\u003c\/p\u003e\n\n\u003cp\u003eThe VE.Direct port is a key practical feature for professional installations. It allows the inverter to be connected to Victron GX devices, enabling remote monitoring and system integration without additional hardware. Configuration and live data can also be accessed via VictronConnect using an appropriate VE.Direct interface adapter. This makes the unit straightforward to commission and diagnose on site.\u003c\/p\u003e\n\n\u003cp\u003eAt 800VA, this inverter is suited to moderate loads: lighting circuits, small appliances, power tools and similar equipment. It is not intended for high-draw loads such as large inverter air conditioning units or electric water heaters. Sizing the inverter correctly to the expected load and battery capacity is essential for reliable operation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN121801100\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e800VA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Direct\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Connector\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIEC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e6 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076047148\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid cabins, lodges and outbuildings powered by a 12V battery and solar system\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations requiring 230V AC from a 12V DC bank\u003c\/li\u003e\n  \u003cli\u003eVehicle conversions (campervan, motorhome) needing a mains-quality AC supply\u003c\/li\u003e\n  \u003cli\u003eBackup power for small office or domestic loads during grid outages\u003c\/li\u003e\n  \u003cli\u003eTelecoms and remote monitoring enclosures requiring a clean AC supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Inverter 12\/800 230V VE.Direct IEC unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis inverter operates at 12V DC and must be connected to an appropriately rated battery bank with correctly sized DC cabling and fusing. DC wiring for inverters carries high current and must be installed by a competent person familiar with low-voltage DC systems. The IEC AC output is not intended for connection to a fixed building wiring circuit without appropriate isolation and protection. For any installation forming part of a fixed electrical system, work must be carried out by a qualified electrician in accordance with BS 7671. This inverter is not a grid-tied device and does not require G98 or G99 notification.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863682351438,"sku":"PIN121801100","price":167.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PIN121801100_-_Inverter_12-800_230V_VE.Direct_IEC.webp?v=1781183391","url":"https:\/\/voltaconsolar.com\/products\/victron-inverter-12-800-230v-ve-direct-iec","provider":"VoltaconSolar","version":"1.0","type":"link"}