{"product_id":"victron-inverter-24-3000-230v-ve-bus","title":"Victron Inverter 24\/3000 230V VE.Bus - PIN243020000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Inverter 24\/3000 230V VE.Bus\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Inverter 24\/3000 230V is a pure sine wave inverter designed for off-grid and backup power applications. It converts 24V DC battery power to 230V AC at 3000VA continuous output, making it suitable for professional installations in marine, vehicle, telecom and off-grid energy systems. VE.Bus connectivity allows integration with Victron system components and remote monitoring.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3000VA continuous output at 230V AC from a 24V DC battery bank.\u003c\/li\u003e\n  \u003cli\u003ePure sine wave output suitable for sensitive electronics and motor loads.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus interface for system integration, parallel operation and remote configuration via Victron GX devices.\u003c\/li\u003e\n  \u003cli\u003eSupports parallel and three-phase configuration with additional compatible Victron inverters.\u003c\/li\u003e\n  \u003cli\u003eProgrammable relay for generator start, alarm or load-shedding functions.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in battery protection with low voltage shutdown, temperature compensation and overload protection.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VE.Configure software for advanced parameter adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 24\/3000 sits in the mid-range of Victron's inverter line, offering a 3000VA output from a 24V battery system. The VE.Bus communication port is the key differentiator from simpler inverter models. It allows the unit to be networked with Victron Quattro or MultiPlus units, stacked in parallel for higher output capacity, or configured in a three-phase arrangement. For installers building scalable off-grid or backup systems, this flexibility reduces the need to oversize a single unit at the outset.\u003c\/p\u003e\n\n\u003cp\u003ePure sine wave output means the inverter is compatible with inductive loads such as motors, pumps and compressors, as well as sensitive electronics that would be damaged or disrupted by modified sine wave power. The unit includes comprehensive battery management features: low voltage disconnect protects the battery bank from deep discharge, and temperature-compensated voltage thresholds improve accuracy across varying ambient conditions.\u003c\/p\u003e\n\n\u003cp\u003eVE.Bus also enables remote monitoring and control through Victron's GX device ecosystem, including the Cerbo GX and Color Control GX. System data can be viewed and managed via the VRM online portal, which is relevant for remote installations where on-site intervention is not practical.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN243020000\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3000VA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e18.5 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076023722\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and cabin installations with 24V battery banks.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat electrical systems requiring 230V AC output.\u003c\/li\u003e\n  \u003cli\u003eVehicle conversions including motorhomes and expedition vehicles.\u003c\/li\u003e\n  \u003cli\u003eTelecom and remote infrastructure backup power.\u003c\/li\u003e\n  \u003cli\u003eScalable off-grid systems where parallel or three-phase expansion is planned.\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial backup power where VE.Bus system integration is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Inverter 24\/3000 230V VE.Bus unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis inverter operates at high DC currents from a 24V battery bank and must be installed by a qualified electrician or experienced system integrator. Correct cable sizing, fusing and battery connection torque are critical for safe operation. VE.Bus configuration requires Victron VE.Configure software and a suitable interface cable or MK3-USB adapter. For any grid-connected or generator-integrated application, ensure compliance with current UK wiring regulations and consult a qualified installer. This unit is not a grid-tied inverter and does not hold G98 or G99 approval.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59864550965582,"sku":"PIN243020000","price":781.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PIN243020000_-_Inverter_24-3000_230V_VE.Bus.webp?v=1781187813","url":"https:\/\/voltaconsolar.com\/products\/victron-inverter-24-3000-230v-ve-bus","provider":"VoltaconSolar","version":"1.0","type":"link"}