{"product_id":"victron-inverter-compact-24-2000-230v-vebus","title":"Victron Inverter Compact 24\/2000 230V VE.Bus - CIN242200000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Inverter Compact 24\/2000 230V VE.Bus — CIN242200000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Inverter Compact 24\/2000 is a 2000VA pure sine wave inverter designed for 24V DC battery systems, producing a 230V AC output. It is built for professional off-grid and mobile power installations where reliable AC conversion from a 24V bank is required. The VE.Bus communication interface allows integration with Victron monitoring and control systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2000VA continuous output from a 24V DC input, delivering 230V AC pure sine wave power.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus interface enables connection to Victron GX devices, Color Control GX, and system monitoring platforms.\u003c\/li\u003e\n  \u003cli\u003eCompact form factor at 13 kg, suited to installations where space and weight are constrained.\u003c\/li\u003e\n  \u003cli\u003ePure sine wave output is compatible with sensitive electronics, motors, and compressor-based loads.\u003c\/li\u003e\n  \u003cli\u003eDesigned for integration into larger Victron systems, including parallel and three-phase configurations where supported by the VE.Bus architecture.\u003c\/li\u003e\n  \u003cli\u003eSuitable for permanent installation in vehicles, vessels, off-grid cabins, and backup power setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Compact 24\/2000 sits within Victron's inverter range as a mid-capacity unit for 24V systems. The 2000VA rating covers a broad range of AC loads, from lighting and small appliances through to power tools and refrigeration, provided the load profile is matched to the inverter's continuous and peak ratings. The compact chassis makes it practical for van conversions, narrowboats, and off-grid buildings where panel space is limited.\u003c\/p\u003e\n\n\u003cp\u003eThe VE.Bus interface is a key differentiator from basic inverters. It allows the unit to communicate with Victron's GX range of system controllers, enabling remote monitoring, programmable relay functions, and integration with battery management systems. For installers building out a full Victron ecosystem, this connectivity is essential for system visibility and control.\u003c\/p\u003e\n\n\u003cp\u003eAs with all Victron inverters, the output is a true sine wave, which matters for loads that are sensitive to waveform quality. Modified sine wave inverters can cause problems with certain motor-driven appliances, audio equipment, and medical devices. The Compact 24\/2000 avoids these issues entirely.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCIN242200000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e2000VA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e13 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076037521\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid cabins and rural properties running on 24V battery banks.\u003c\/li\u003e\n  \u003cli\u003eMarine installations on sailing yachts and motorboats with 24V DC systems.\u003c\/li\u003e\n  \u003cli\u003eVan and motorhome conversions requiring 230V AC output from a 24V leisure battery bank.\u003c\/li\u003e\n  \u003cli\u003eNarrowboat and canal boat electrical systems.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems where a 24V battery provides AC supply during mains outages.\u003c\/li\u003e\n  \u003cli\u003eVictron system builds requiring VE.Bus-connected inverter control and monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Inverter Compact 24\/2000 230V VE.Bus unit (CIN242200000)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis inverter must be installed by a qualified electrician or competent person familiar with DC and AC electrical systems. DC cable sizing between the battery bank and inverter is critical at 24V: high current draw at full load requires correctly rated, short cable runs with appropriate fusing. The VE.Bus interface requires a compatible Victron GX device or MK3-USB adapter for configuration and monitoring. This unit is not grid-connected and does not require G98 or G99 notification. For any installation on a vessel, compliance with relevant marine electrical standards should be confirmed with a qualified marine electrician.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47701237039438,"sku":"CIN242200000","price":544.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-phoenix-inverter-compact-242000-230v-vebus-cin242200000-174169.jpg?v=1747944152","url":"https:\/\/voltaconsolar.com\/products\/victron-inverter-compact-24-2000-230v-vebus","provider":"VoltaconSolar","version":"1.0","type":"link"}