{"product_id":"victron-mega-fuse-200a-58v-48v-cip137200010","title":"Victron MEGA-fuse 200A\/58V-48Vprod(1 pc) *If 0, order CIP138200020* - CIP137200010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 200A\/58V for 48V Systems (1 pc) — CIP137200010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MEGA-Fuse 200A\/58V is a high-current blade-style fuse designed for overcurrent protection in 48V battery systems. It is used in conjunction with a compatible MEGA fuseholder and is suited to professional solar, off-grid and battery storage installations where reliable DC circuit protection is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 200A continuous current with a 58V DC voltage rating, suitable for 48V nominal battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA-fuse format provides a compact, high-current protection solution for DC busbars and battery connections.\u003c\/li\u003e\n  \u003cli\u003eSingle fuse per pack (1 pc), allowing replacement or sparing without purchasing in bulk.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron MEGA fuseholders for a secure, low-resistance connection.\u003c\/li\u003e\n  \u003cli\u003eWeighs just 9 grams, making it easy to carry as a spare on site.\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076016694, confirming genuine Victron Energy product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a standard format for high-current DC overcurrent protection in battery-based systems. The 200A rating makes this fuse appropriate for protecting cables and equipment connected to 48V battery banks, including inverter feeds, busbar connections and DC distribution points. The 58V voltage rating provides adequate headroom above the maximum charge voltage of a 48V lithium or lead-acid battery bank.\u003c\/p\u003e\n\n\u003cp\u003eThis fuse is sold individually (1 pc). If the stock quantity shows zero, Victron recommends ordering the equivalent twin-pack under SKU CIP138200020. Always check that the fuseholder fitted on site is rated for MEGA-format fuses before ordering replacements.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCIP137200010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCurrent Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e200A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVoltage Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e58V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eNominal System Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eFuse Format\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMEGA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePack Quantity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e1 pc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e9 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076016694\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on 48V battery bank output cables in off-grid solar systems.\u003c\/li\u003e\n  \u003cli\u003eFuse replacement in existing Victron MEGA fuseholder installations.\u003c\/li\u003e\n  \u003cli\u003eDC busbar protection in battery storage systems using 48V lithium or lead-acid batteries.\u003c\/li\u003e\n  \u003cli\u003eInverter feed protection where the inverter draw does not exceed 200A continuous.\u003c\/li\u003e\n  \u003cli\u003eSpare fuse carried on site by installers working on 48V DC systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron MEGA-Fuse 200A\/58V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis fuse must be installed in a compatible MEGA-format fuseholder rated for the application voltage and current. DC fusing in battery systems should be carried out by a qualified electrician or accredited installer familiar with high-current DC circuits. Ensure the fuse rating matches the cable ampacity and the connected equipment's maximum current draw. Do not substitute with a higher-rated fuse to resolve nuisance tripping; investigate the root cause of any overcurrent event before replacing.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47435134828878,"sku":"CIP137200010","price":23.78,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/mega-fuse-200a58v-for-48v-products-1-pc-cip137200010-163522.jpg?v=1747934704","url":"https:\/\/voltaconsolar.com\/products\/victron-mega-fuse-200a-58v-48v-cip137200010","provider":"VoltaconSolar","version":"1.0","type":"link"}