{"product_id":"victron-midi-fuse-100a-58v-m6-pack-5","title":"Victron MIDI-fuse 100A\/58V-M6 (package of 5 pcs) - CIP134100020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MIDI Fuse 100A\/58V M6 (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MIDI fuse 100A\/58V with M6 bolt connection is a blade-style DC fuse designed for use in battery and solar systems where overcurrent protection is required on high-current DC cables. Sold in packs of five, these fuses are suited to professional installers who need reliable, repeatable protection across multiple installations or battery strings.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100A rated current with a 58V DC voltage rating, suitable for 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eM6 bolt terminal connection for a secure, low-resistance contact in MIDI fuseholders.\u003c\/li\u003e\n  \u003cli\u003eMIDI form factor, compatible with standard MIDI fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eSold as a pack of 5, reducing per-unit cost for trade and multi-installation use.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 15g per pack, with minimal footprint for installation in tight enclosures or battery compartments.\u003c\/li\u003e\n  \u003cli\u003eSKU CIP134100020, GTIN 8719076061595 for straightforward ordering and stock management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses are a widely used format in DC electrical protection, particularly in battery-based energy systems, marine installations and off-grid setups. The 100A rating makes this fuse appropriate for protecting main DC cables in systems where sustained high-current draw is expected, such as inverter feeds, battery interconnects or charge controller outputs. The 58V voltage rating covers the full operating range of 48V battery banks, including the elevated voltages seen during charging.\u003c\/p\u003e\n\n\u003cp\u003eThe M6 bolt terminal ensures a firm mechanical connection within the fuseholder, which is important in mobile or vibration-prone environments such as vehicles, boats and caravans. A loose or corroded fuse connection can introduce resistance and heat, so the bolted MIDI format is preferred over blade fuses in higher-current DC applications. These fuses are single-use protection devices and must be replaced after any overcurrent event.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP134100020\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076061595\u003c\/li\u003e\n  \u003cli\u003eRated current: 100A\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 58V DC\u003c\/li\u003e\n  \u003cli\u003eTerminal type: M6 bolt\u003c\/li\u003e\n  \u003cli\u003eForm factor: MIDI\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.015 kg (per pack)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on DC cables in 12V, 24V and 48V battery systems.\u003c\/li\u003e\n  \u003cli\u003eInverter and inverter\/charger feed protection in off-grid and backup power installations.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat DC distribution boards and battery banks.\u003c\/li\u003e\n  \u003cli\u003eMotorhome, caravan and vehicle conversion DC wiring protection.\u003c\/li\u003e\n  \u003cli\u003eSolar charge controller output protection in standalone PV systems.\u003c\/li\u003e\n  \u003cli\u003eBattery string protection in multi-battery off-grid installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron MIDI fuse 100A\/58V M6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses must be installed in a compatible MIDI fuseholder rated for the voltage and current of the circuit. Ensure the M6 bolt is torqued to the fuseholder manufacturer's specification to maintain a low-resistance connection. DC electrical work on battery systems, inverters and solar installations should be carried out by a qualified electrician or accredited installer. Always isolate the battery before replacing a fuse. Do not use these fuses in AC circuits or in applications exceeding 58V DC.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59856059695438,"sku":"CIP134100020","price":9.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP134100020_-_MIDI-fuse_100A-58V-M6_package_of_5_pcs.webp?v=1781101993","url":"https:\/\/voltaconsolar.com\/products\/victron-midi-fuse-100a-58v-m6-pack-5","provider":"VoltaconSolar","version":"1.0","type":"link"}