{"product_id":"victron-midi-fuse-125a-32v-pack-of-5","title":"Victron MIDI-fuse 125A\/32V (package of 5 pcs) - CIP132125010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy MIDI Fuse 125A\/32V (Pack of 5)\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MIDI fuse is a 125A, 32V DC bolt-down fuse designed for use in 12V and 24V battery systems. Supplied in a pack of five, it is suited to professional installers and system builders who need reliable overcurrent protection for DC cabling in solar, off-grid and marine applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 125A continuous current with a 32V DC voltage rating.\u003c\/li\u003e\n  \u003cli\u003eMIDI form factor, compatible with standard MIDI fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eBolt-down blade design provides a low-resistance, secure connection in high-current DC circuits.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a pack of 5, reducing per-unit cost for multi-system installations or service stock.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 11g per pack, making them practical to carry as spares on site.\u003c\/li\u003e\n  \u003cli\u003eSKU CIP132125010, GTIN 8719076054658, sourced directly from Victron Energy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses are a compact, bolt-down fuse format widely used in DC battery protection circuits. The 125A rating makes this fuse appropriate for protecting main DC cables in 12V and 24V systems, including battery-to-inverter runs, busbar feeds and charge controller output wiring. At 32V DC, the voltage rating comfortably covers both 12V and 24V nominal battery banks.\u003c\/p\u003e\n\n\u003cp\u003eUsing the correct fuse rating for the cable cross-section is essential. A 125A fuse is typically paired with 35mm² to 50mm² DC cable, depending on cable length and installation conditions. Victron MIDI fuses are designed to work with Victron MIDI fuseholders, ensuring a consistent contact interface and avoiding the resistance issues that can arise from mismatched fuse and holder combinations.\u003c\/p\u003e\n\n\u003cp\u003eBuying in packs of five is practical for installers completing multiple systems or for keeping service stock on hand. MIDI fuses are a consumable item and having spares available on site avoids delays when a fuse operates during commissioning or fault conditions.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP132125010\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 125A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 32V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MIDI bolt-down blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.011 kg per pack\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076054658\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection on main DC battery cables in 12V and 24V off-grid solar systems.\u003c\/li\u003e\n  \u003cli\u003eFusing battery-to-inverter connections in mobile, marine and vehicle installations.\u003c\/li\u003e\n  \u003cli\u003eProtecting DC distribution feeds from battery banks to busbars or combiners.\u003c\/li\u003e\n  \u003cli\u003eService and replacement stock for installers maintaining existing Victron-based systems.\u003c\/li\u003e\n  \u003cli\u003eMulti-system installation projects where several fuses are required across a single job.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MIDI fuse, 125A\/32V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMIDI fuses must be installed in a compatible MIDI fuseholder. Ensure the fuseholder is rated for the current and voltage of the circuit. DC fusing in battery systems should be installed as close to the positive battery terminal as practicable to protect the full cable run. All DC wiring and fusing work on battery systems should be carried out by a qualified electrician or accredited installer familiar with DC system design. Do not substitute a higher-rated fuse than the cable is rated to carry.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59855248916814,"sku":"CIP132125010","price":7.64,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_CIP132125010_-_MIDI-fuse_125A-32V_package_of_5_pcs.webp?v=1781091876","url":"https:\/\/voltaconsolar.com\/products\/victron-midi-fuse-125a-32v-pack-of-5","provider":"VoltaconSolar","version":"1.0","type":"link"}