{"product_id":"victron-multi-rs-48-6000-100-50-230v","title":"Victron Multi RS 48\/6000\/100-50 230V - PMR482604000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Multi RS 48\/6000\/100-50 230V Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Multi RS 48\/6000\/100-50 is a 6000VA inverter charger designed for 48V battery systems operating at 230V AC. It combines a high-frequency inverter, a 100A battery charger, and a 50A solar charge controller (MPPT) in a single unit, making it suited to off-grid installations, hybrid solar systems, and backup power applications where space and wiring complexity need to be minimised.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e6000VA continuous inverter output at 230V AC from a 48V DC battery bank.\u003c\/li\u003e\n  \u003cli\u003eIntegrated 100A multi-stage battery charger with adaptive charge algorithm.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in 50A MPPT solar charge controller for direct PV array connection.\u003c\/li\u003e\n  \u003cli\u003eHigh-frequency design reduces unit weight to 12.5kg compared to transformer-based equivalents.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VE.Bus for system integration, monitoring and remote configuration via GX devices.\u003c\/li\u003e\n  \u003cli\u003eSupports PowerAssist, allowing the unit to supplement grid or generator input when demand exceeds the AC source capacity.\u003c\/li\u003e\n  \u003cli\u003eConfigurable via VictronConnect app over Bluetooth or VE.Bus interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Multi RS combines three functions that would otherwise require separate hardware: an inverter, a battery charger, and an MPPT solar charge controller. This integration reduces installation complexity, cabinet space, and the number of DC cable runs between components. The 48V nominal battery voltage is well suited to larger off-grid and hybrid systems where higher voltage reduces current and associated cable losses.\u003c\/p\u003e\n\n\u003cp\u003eThe 100A charger output is substantial for a unit of this size, allowing a reasonably large battery bank to be recharged efficiently from a generator or grid supply. The 50A MPPT input handles PV arrays directly, with the charge controller managing the solar harvest and feeding it into the battery bank alongside or independently of the AC charger. This makes the Multi RS a practical choice for sites where both grid or generator backup and solar generation are present.\u003c\/p\u003e\n\n\u003cp\u003eVE.Bus compatibility means the unit integrates fully into a Victron system alongside GX monitoring devices, Venus OS, and the VRM online portal. System behaviour, charge profiles, and transfer thresholds can all be configured remotely once commissioned. The high-frequency architecture keeps the unit at 12.5kg, which is a practical advantage for wall-mounted installations where a transformer-based unit of equivalent output would be considerably heavier.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMR482604000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e6000VA \/ 230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCharger Output\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMPPT Solar Charger\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e50A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12.534 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076075189\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and commercial installations with solar PV and battery storage.\u003c\/li\u003e\n  \u003cli\u003eHybrid solar systems where grid or generator backup is required alongside solar generation.\u003c\/li\u003e\n  \u003cli\u003eRemote sites, agricultural buildings, and cabins requiring a self-contained power system.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle applications where 48V battery banks and 230V AC output are needed.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems for critical loads where fast transfer from grid to battery is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Multi RS 48\/6000\/100-50 230V inverter charger unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe Multi RS 48\/6000\/100-50 should be installed by a qualified electrician or MCS-accredited installer. The unit operates at 48V DC with high current battery connections and connects to 230V AC mains or generator supply. Any grid-connected installation in the UK must comply with G98 or G99 requirements as applicable. PV array wiring and battery cabling must be sized correctly for the current ratings of the integrated charger and MPPT inputs. Configuration via VE.Bus or VictronConnect should be completed before commissioning to ensure charge parameters match the connected battery chemistry.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":60190996136270,"sku":"PMR482604000","price":1131.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PMR482604000_-_Multi_RS_48-6000-100-50_230V.webp?v=1784715759","url":"https:\/\/voltaconsolar.com\/products\/victron-multi-rs-48-6000-100-50-230v","provider":"VoltaconSolar","version":"1.0","type":"link"}