{"product_id":"victron-multiplus-12-2000-80-32-230v-inverter-charger","title":"Victron MultiPlus 12\/2000\/80-32 230V VE.Bus - PMP122200000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus 12\/2000\/80-32 230V VE.Bus Inverter Charger — PMP122200000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus 12\/2000\/80-32 is a combined inverter and battery charger in a single unit, designed for 12V battery systems requiring 230V AC output. It is suited to marine, vehicle, off-grid and backup power installations where a reliable, compact inverter charger is needed. The 80A charger and 32A transfer switch make it a practical choice for installations with shore power or generator input.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2000VA continuous inverter output at 230V AC from a 12V DC battery bank.\u003c\/li\u003e\n  \u003cli\u003e80A multi-stage battery charger with adaptive charge algorithm for lead-acid and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003e32A AC transfer switch with near-instant switchover, suitable for use with shore power or generator input.\u003c\/li\u003e\n  \u003cli\u003ePowerControl function limits the total AC current drawn from shore or generator, preventing overload of the supply.\u003c\/li\u003e\n  \u003cli\u003ePowerAssist function supplements shore or generator power with battery power during peak demand, allowing a smaller AC supply to run larger loads.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus communication port for system integration, remote monitoring and configuration via Victron GX devices or VEConfigure software.\u003c\/li\u003e\n  \u003cli\u003eSupports parallel and three-phase operation when multiple units are used together.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in battery temperature sensor input and programmable relay for system control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus 12\/2000\/80-32 combines a pure sine wave inverter, a multi-stage battery charger and an AC transfer switch into one unit. In inverter mode it converts 12V DC battery power to 230V AC at up to 2000VA continuous, with a 4000VA peak surge capacity for motor starting and inrush loads. The 80A charger uses an adaptive algorithm that adjusts the charge profile based on battery behaviour, which extends battery life compared to fixed-profile chargers.\u003c\/p\u003e\n\n\u003cp\u003eThe 32A transfer switch connects the AC output to the incoming shore or generator supply when it is available, and switches back to inverter mode when that supply is lost or falls outside acceptable voltage and frequency limits. Switchover time is fast enough for most computers and sensitive electronics to remain operational. PowerControl and PowerAssist allow the unit to work within the limits of a restricted AC supply, such as a 16A shore connection, while still running loads that would otherwise exceed that limit.\u003c\/p\u003e\n\n\u003cp\u003eVE.Bus connectivity means the MultiPlus integrates directly with Victron GX devices (such as the Cerbo GX) for system monitoring, data logging and remote control. Multiple units can be configured in parallel for higher power output, or in split or three-phase arrangements for more complex installations. Configuration is carried out using VEConfigure software via a VE.Bus to USB interface.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP122200000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage (Nominal)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power (Continuous)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e2000VA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Output\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e80A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Transfer Switch Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e32A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e15.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076052135\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMarine vessels with 12V battery banks requiring 230V AC for onboard equipment.\u003c\/li\u003e\n  \u003cli\u003eMotorhomes, coaches and large campervans with shore power connections.\u003c\/li\u003e\n  \u003cli\u003eOff-grid cabins and remote buildings where a generator or solar-charged battery bank provides the DC supply.\u003c\/li\u003e\n  \u003cli\u003eUPS and backup power systems for critical loads such as communications equipment or refrigeration.\u003c\/li\u003e\n  \u003cli\u003eMobile workshops and site vehicles requiring 230V AC tool power from a 12V battery system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron MultiPlus 12\/2000\/80-32 230V VE.Bus inverter charger unit.\u003c\/li\u003e\n  \u003cli\u003eTemperature sensor.\u003c\/li\u003e\n  \u003cli\u003eDocumentation pack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation should be carried out by a qualified electrician or accredited installer familiar with DC battery systems and 230V AC wiring. The unit must be connected to an appropriately rated 12V battery bank with correctly sized DC cabling and fusing. For any grid-connected or shore-power application in the UK, relevant wiring regulations (BS 7671) and, where applicable, DNO notification requirements must be observed. VE.Bus configuration requires VEConfigure software and a compatible interface cable. Do not install in an enclosed, unventilated space as the unit generates heat during operation.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47686965363022,"sku":"PMP122200000","price":717.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-multiplus-12200080-32-230v-vebus-pmp122200000-465452.jpg?v=1747943909","url":"https:\/\/voltaconsolar.com\/products\/victron-multiplus-12-2000-80-32-230v-inverter-charger","provider":"VoltaconSolar","version":"1.0","type":"link"}