{"product_id":"victron-multiplus-24-3000-70-16-230v-vebus","title":"Victron MultiPlus 24\/3000\/70-16 230V VE.Bus - PMP242300001","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus 24\/3000\/70-16 230V VE.Bus Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus 24\/3000\/70-16 is a combined inverter and battery charger designed for off-grid, backup and marine or vehicle applications running on a 24V battery bank. It delivers 3000VA of continuous AC output at 230V and includes a 70A battery charger, making it a practical single-unit solution for installations where both inversion and charging are required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3000VA continuous inverter output with 230V AC, suitable for demanding off-grid and backup loads.\u003c\/li\u003e\n  \u003cli\u003e70A multi-stage battery charger built in, supporting a wide range of 24V battery chemistries including AGM, gel, lithium and flooded lead-acid.\u003c\/li\u003e\n  \u003cli\u003e16A AC transfer switch with PowerControl and PowerAssist functions, allowing the unit to supplement shore or generator power rather than replace it entirely.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus communication interface for system integration, remote monitoring and configuration via Victron GX devices or VEConfigure software.\u003c\/li\u003e\n  \u003cli\u003eVirtually unlimited parallel and three-phase capability: multiple units can be stacked to increase capacity or configured for three-phase output.\u003c\/li\u003e\n  \u003cli\u003eUPS-grade transfer time of less than 20ms, ensuring uninterrupted supply to sensitive loads during a mains failure.\u003c\/li\u003e\n  \u003cli\u003eProgrammable relay for generator start, alarm or other auxiliary functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus combines a true sine wave inverter with a sophisticated battery charger in a single enclosure. The inverter section produces a clean 230V AC sine wave from a 24V DC battery bank, with a 3000VA continuous rating and a 6000VA peak surge capacity to handle motor start loads. The charger uses an adaptive multi-stage algorithm that adjusts to battery condition over time, which extends battery service life compared to fixed-rate charging.\u003c\/p\u003e\n\n\u003cp\u003ePowerAssist is one of the more practically useful features for installations with a limited AC supply, such as a shore power connection or a small generator. When the connected AC source approaches its current limit, the MultiPlus draws the shortfall from the battery bank rather than overloading the source. This means a 16A shore supply can support loads that would otherwise exceed it, without tripping a breaker or overloading a generator. PowerControl performs the same function as a static current limiter when PowerAssist is not required.\u003c\/p\u003e\n\n\u003cp\u003eVE.Bus connectivity allows the MultiPlus to be integrated into a wider Victron system. It can be monitored and configured remotely via a Cerbo GX or other GX device, and multiple units can be paralleled for higher output or wired in a split configuration for three-phase systems. This makes the 24\/3000\/70-16 a scalable building block rather than a fixed-capacity unit.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP242300001\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3000VA \/ 2500W\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePeak Output Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e6000VA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Frequency\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e50Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Output\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e70A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Transfer Switch Rating\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e16A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eTransfer Time (UPS mode)\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u0026lt;20ms\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e18.85 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076045168\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and cabin systems with a 24V battery bank requiring both inversion and charging from a generator or shore supply.\u003c\/li\u003e\n  \u003cli\u003eMarine installations where shore power is available in port but battery-backed AC is needed at sea.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome conversions requiring 230V AC output from a 24V house battery system.\u003c\/li\u003e\n  \u003cli\u003eCritical backup power for IT equipment, communications or medical devices where sub-20ms transfer time is required.\u003c\/li\u003e\n  \u003cli\u003eScalable multi-unit systems where parallel stacking or three-phase output is needed as load requirements grow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron MultiPlus 24\/3000\/70-16 230V VE.Bus inverter charger unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation must be carried out by a qualified electrician familiar with DC battery systems and 230V AC wiring. The MultiPlus is not certified for grid-tied export in the UK and should not be connected to the public grid without appropriate isolation and compliance measures. For systems incorporating lithium batteries, battery-specific charge parameters must be configured using VEConfigure or a compatible GX device before commissioning. DC cable sizing and fusing must be appropriate for the high currents involved at 24V. Secure the unit in a well-ventilated location away from flammable materials.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863702602062,"sku":"PMP242300001","price":919.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PMP242300001_-_MultiPlus_24-3000-70-16_230V_VE.Bus.webp?v=1781183560","url":"https:\/\/voltaconsolar.com\/products\/victron-multiplus-24-3000-70-16-230v-vebus","provider":"VoltaconSolar","version":"1.0","type":"link"}