{"product_id":"victron-multiplus-24-3000-70-50-230v-vebus","title":"Victron MultiPlus 24\/3000\/70-50 230V VE.Bus - PMP242301011","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus 24\/3000\/70-50 230V VE.Bus Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus 24\/3000\/70-50 is a combined inverter and battery charger in a single unit, designed for 24V battery systems with a 3000VA inverter output and 70A charging capacity. It is suited to off-grid installations, marine and vehicle applications, and backup power systems where a reliable, programmable inverter charger is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3000VA continuous inverter output with a 230V AC output, suitable for demanding loads.\u003c\/li\u003e\n  \u003cli\u003e70A multi-stage battery charger with adaptive charge algorithm, compatible with a wide range of battery chemistries including lead-acid and lithium.\u003c\/li\u003e\n  \u003cli\u003e50A AC transfer switch allows connection of a shore power or generator input, with near-instant transfer to inverter on power loss.\u003c\/li\u003e\n  \u003cli\u003ePowerControl and PowerAssist functions limit the draw on shore or generator power by supplementing with battery power when loads exceed the input current limit.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus communication interface enables system integration, parallel operation, and three-phase configuration with additional MultiPlus units.\u003c\/li\u003e\n  \u003cli\u003eProgrammable via VE.Bus and compatible with Victron's VEConfigure software for full control over charge parameters, transfer thresholds, and input current limits.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in battery temperature sensor input and voltage sense for accurate charging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus 24\/3000\/70-50 combines a true sine wave inverter with a high-current battery charger and an AC transfer switch. When AC input is available from shore power or a generator, the unit charges the battery bank and passes power through to connected loads. When AC input is lost or falls outside acceptable parameters, the transfer switch activates in under 20 milliseconds, maintaining supply to critical loads without interruption.\u003c\/p\u003e\n\n\u003cp\u003eThe PowerAssist feature is particularly useful in installations where the available AC input is limited, such as a small generator or a restricted shore power connection. When loads exceed the input current limit set by the installer, the MultiPlus draws the shortfall from the battery bank rather than overloading the source. This allows a smaller generator to run reliably alongside a larger load profile.\u003c\/p\u003e\n\n\u003cp\u003eVE.Bus connectivity means the unit can be monitored and configured remotely, integrated into a Victron GX system (such as a Cerbo GX), and expanded. Multiple MultiPlus units can be connected in parallel to increase output capacity, or configured for split-phase or three-phase operation. This makes the 24\/3000\/70-50 a practical building block for scalable off-grid and backup power systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP242301011\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3000VA \/ 2400W continuous\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC, 50Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eTrue sine wave\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Current\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e70A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Transfer Switch\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e50A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Voltage Range\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e18.85 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076045175\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and cabin installations with 24V battery banks.\u003c\/li\u003e\n  \u003cli\u003eMarine vessels requiring shore power integration and battery charging.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome conversions with high AC load requirements.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems for critical equipment where sub-20ms transfer time is required.\u003c\/li\u003e\n  \u003cli\u003eGenerator management systems where PowerAssist reduces generator sizing requirements.\u003c\/li\u003e\n  \u003cli\u003eScalable off-grid systems using parallel or three-phase MultiPlus configurations via VE.Bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron MultiPlus 24\/3000\/70-50 230V VE.Bus inverter charger unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation should be carried out by a qualified electrician or accredited installer familiar with DC battery systems and AC wiring regulations. The MultiPlus must be correctly fused on the DC side in accordance with the battery bank capacity and cable ratings. For any grid-connected or generator-connected application, compliance with current UK wiring regulations (BS 7671) is required. Configuration via VEConfigure or the VictronConnect app is recommended before commissioning to set appropriate charge voltages, input current limits, and transfer thresholds for the specific battery chemistry and installation. Do not connect to a public grid supply without confirming the applicable G98 or G99 requirements with your Distribution Network Operator.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59864569282894,"sku":"PMP242301011","price":992.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PMP242301011_-_MultiPlus_24-3000-70-50_230V_VE.Bus.webp?v=1781187866","url":"https:\/\/voltaconsolar.com\/products\/victron-multiplus-24-3000-70-50-230v-vebus","provider":"VoltaconSolar","version":"1.0","type":"link"}