{"product_id":"victron-multiplus-48-3000-35-50-230v-vebus","title":"Victron MultiPlus 48\/3000\/35-50 230V VE.Bus - PMP483021010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus 48\/3000\/35-50 230V VE.Bus Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus 48\/3000\/35-50 is a combined inverter and battery charger in a single unit, designed for 48V battery systems operating at 230V AC. It is suited to off-grid installations, backup power systems, and marine or vehicle applications where reliable AC output and controlled battery charging are required from one compact device.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3000VA continuous inverter output at 230V AC from a 48V DC battery bank.\u003c\/li\u003e\n  \u003cli\u003e35A battery charger built in, with a 50A AC transfer switch for grid or generator input.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus communication interface allows parallel and three-phase configuration with additional MultiPlus units.\u003c\/li\u003e\n  \u003cli\u003ePowerControl function limits the load on the AC input, preventing generator or shore power overload.\u003c\/li\u003e\n  \u003cli\u003ePowerAssist function supplements AC input with battery power during peak demand, allowing a smaller generator or grid connection to be used.\u003c\/li\u003e\n  \u003cli\u003eAdaptive battery charging algorithm adjusts charge profile based on battery behaviour to extend battery life.\u003c\/li\u003e\n  \u003cli\u003eTransfer switch operates in under 20 milliseconds, maintaining supply to connected loads during input switching.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron GX devices and VEConfigure software for remote monitoring and configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus 48\/3000\/35-50 combines a pure sine wave inverter with a multi-stage battery charger. The 3000VA output is continuous, not peak, which matters when sizing for real loads such as pumps, compressors or power tools that draw sustained current. The 48V battery voltage is the preferred choice for larger off-grid systems because it reduces cable losses and allows more usable energy from a given battery bank compared to 12V or 24V configurations.\u003c\/p\u003e\n\n\u003cp\u003eThe VE.Bus interface is central to the unit's flexibility. Up to three MultiPlus units can be wired in parallel to increase output capacity, or configured in a split-phase or three-phase arrangement. This makes the MultiPlus scalable from a single-unit residential backup system through to larger commercial or industrial installations. Configuration is handled via VEConfigure software, and the unit integrates with Victron's GX range (Cerbo GX, Color Control GX) for system monitoring and remote management via the VRM portal.\u003c\/p\u003e\n\n\u003cp\u003ePowerControl and PowerAssist are practical features for installations with a limited AC supply. PowerControl caps the charger current to avoid tripping a generator or shore power breaker. PowerAssist goes further: when load demand exceeds what the AC input can supply, the inverter draws from the battery to make up the difference. This allows a smaller, more fuel-efficient generator to be used without risking overload trips.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP483021010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3000VA \/ 2400W continuous\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e35A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Transfer Switch\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e50A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eTransfer Time\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eLess than 20ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e18 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076024057\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and rural properties requiring a reliable 230V AC supply from a 48V battery bank.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems for critical loads where fast transfer time is required during mains failure.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations with 48V DC systems and shore power connection.\u003c\/li\u003e\n  \u003cli\u003eMobile or vehicle-based power systems such as expedition vehicles or large motorhomes.\u003c\/li\u003e\n  \u003cli\u003eScalable multi-unit installations requiring parallel or three-phase output via VE.Bus.\u003c\/li\u003e\n  \u003cli\u003eGenerator-assisted off-grid systems where PowerAssist reduces generator run time and fuel consumption.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron MultiPlus 48\/3000\/35-50 230V VE.Bus inverter charger unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus 48\/3000\/35-50 operates at 48V DC and handles significant DC current at full load. Installation must be carried out by a qualified electrician or accredited installer. All DC cabling, fusing and battery connections must be rated appropriately for the system. Where the unit is connected to a grid supply or used as part of a grid-tied or backup system in the UK, compliance with G98 or G99 requirements and notification to the local Distribution Network Operator (DNO) may be required depending on the configuration. VEConfigure software is needed for advanced setup, including charger current limits, PowerControl thresholds and parallel or three-phase configuration.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863705682254,"sku":"PMP483021010","price":664.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PMP483021010_-_MultiPlus_48-3000-35-50_230V_VE.Bus.webp?v=1781183570","url":"https:\/\/voltaconsolar.com\/products\/victron-multiplus-48-3000-35-50-230v-vebus","provider":"VoltaconSolar","version":"1.0","type":"link"}