{"product_id":"victron-multiplus-48-800-9-16-230v-vebus","title":"Victron MultiPlus 48\/800\/9-16 230V VE.Bus - PMP481800000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus 48\/800\/9-16 230V VE.Bus Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus 48\/800\/9-16 is a combined inverter and battery charger in a single compact unit, designed for 48V off-grid and backup power systems operating at 230V AC. It is suited to professional installers working on small off-grid installations, narrowboats, caravans, remote cabins, and UPS applications where a reliable, low-power inverter charger is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCombined inverter and charger in one unit, eliminating the need for separate devices in space-constrained installations.\u003c\/li\u003e\n  \u003cli\u003e800VA continuous inverter output at 230V AC from a 48V DC battery bank.\u003c\/li\u003e\n  \u003cli\u003e9A battery charging current, with a 16A AC input current rating for shore or generator power.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus communication interface for system integration, parallel operation, and monitoring via Victron GX devices.\u003c\/li\u003e\n  \u003cli\u003ePowerAssist function supplements shore or generator power when demand exceeds the available AC input, preventing overload.\u003c\/li\u003e\n  \u003cli\u003eTransfer switch with a fast changeover time, suitable for use as an uninterruptible power supply (UPS).\u003c\/li\u003e\n  \u003cli\u003eConfigurable via VE.Bus and compatible with Victron VE.Configure software for parameter adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus 48\/800\/9-16 operates from a 48V battery bank and delivers 800VA of continuous AC output at 230V. The 48V architecture reduces cable current compared to 12V or 24V equivalents, which is a practical advantage in installations where cable runs are longer or where efficiency losses need to be minimised. The 9A charger is sized for smaller battery banks and is appropriate for systems where charging speed is less critical than compact footprint and low cost.\u003c\/p\u003e\n\n\u003cp\u003eVE.Bus connectivity is a key feature of this unit. It allows the MultiPlus to be monitored and controlled through Victron GX devices such as the Cerbo GX, and it supports configuration via VE.Configure software. Multiple units can be connected in parallel or in split-phase configurations where the system design requires it, though the 800VA model is most commonly deployed as a standalone unit in small systems.\u003c\/p\u003e\n\n\u003cp\u003eThe PowerAssist function is particularly useful in installations with a limited AC input, such as a small generator or a restricted shore power connection. When load demand exceeds the available input current, the unit draws the balance from the battery, allowing the system to handle short-term peaks without tripping the input breaker or overloading the source.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP481800000\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e800VA \/ 230V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Output\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e9A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Current Rating\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e16A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e6.5 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076038245\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSmall off-grid cabins and remote buildings with a 48V battery bank.\u003c\/li\u003e\n  \u003cli\u003eNarrowboats and canal boats requiring 230V AC from a 48V DC system.\u003c\/li\u003e\n  \u003cli\u003eCaravan and motorhome installations with 48V lithium battery systems.\u003c\/li\u003e\n  \u003cli\u003eUPS and backup power applications where fast transfer to battery is required.\u003c\/li\u003e\n  \u003cli\u003eSmall solar off-grid systems paired with a Victron MPPT charge controller and GX monitoring device.\u003c\/li\u003e\n  \u003cli\u003eTelecoms and remote equipment enclosures requiring a compact 48V inverter charger.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron MultiPlus 48\/800\/9-16 230V VE.Bus inverter charger unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation must be carried out by a qualified electrician or accredited installer. The MultiPlus connects directly to a 48V battery bank and to a 230V AC supply, both of which present serious electrical hazards if wired incorrectly. Ensure battery cabling is correctly rated for the DC current involved and that appropriate fusing is fitted on the battery connection. This unit is not certified for grid-tied export in the UK and must not be connected to the grid without appropriate isolation and compliance with G98 or G99 requirements. For off-grid and UPS applications, follow Victron's published wiring guidelines and use VE.Configure software to set battery parameters appropriate to the chemistry in use.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":60201801023822,"sku":"PMP481800000","price":235.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PMP481800000_-_MultiPlus_48-800-9-16_230V_VE.Bus.webp?v=1784819115","url":"https:\/\/voltaconsolar.com\/products\/victron-multiplus-48-800-9-16-230v-vebus","provider":"VoltaconSolar","version":"1.0","type":"link"}