{"product_id":"victron-multiplus-ii-24-3000-70-32-230v-gx","title":"Victron MultiPlus-II 24\/3000\/70-32 230V GX - PMP242306000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus-II 24\/3000\/70-32 230V GX — PMP242306000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus-II 24\/3000\/70-32 230V GX is a combined inverter, battery charger and transfer switch with an integrated GX device for system monitoring and control. It is designed for off-grid installations, backup power systems and solar storage applications where a single, integrated unit is preferred over separate components. The built-in GX controller removes the need for an external Cerbo GX or Color Control GX, reducing wiring complexity and overall system cost.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3000VA continuous inverter output at 230V AC from a 24V DC battery bank.\u003c\/li\u003e\n  \u003cli\u003e70A battery charger with adaptive charging algorithm to suit flooded, gel, AGM and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003e32A AC input current limit, adjustable via the GX interface or VEConfigure software.\u003c\/li\u003e\n  \u003cli\u003eIntegrated GX device provides built-in VRM portal connectivity, DVCC support and local monitoring without additional hardware.\u003c\/li\u003e\n  \u003cli\u003ePowerControl and PowerAssist functions prevent overloading a generator or shore power supply by limiting AC input draw and supplementing with battery power when demand exceeds the set threshold.\u003c\/li\u003e\n  \u003cli\u003eNear-instant transfer switch (less than 20ms) between grid or generator and inverter, suitable for loads sensitive to supply interruption.\u003c\/li\u003e\n  \u003cli\u003eSupports ESS (Energy Storage System) configuration for grid-tied battery storage with self-consumption and feed-in control.\u003c\/li\u003e\n  \u003cli\u003eCompatible with VE.Bus, VE.Can and VE.Direct peripherals for full system integration with Victron MPPT chargers, BMV battery monitors and other devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II GX combines what would otherwise be three separate units: an inverter, a charger and a GX monitoring controller. The 24V input voltage makes it well suited to medium-capacity battery banks where 24V architecture is preferred over 48V, particularly in marine, vehicle and smaller off-grid cabin installations. The 3000VA output is sufficient for most domestic loads including refrigeration, lighting, small power tools and consumer electronics.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated GX device runs the same VenusOS firmware found in the Cerbo GX and Color Control GX. This means full access to the VRM online portal for remote monitoring, DVCC (Distributed Voltage and Current Control) for managed battery charging, and compatibility with the full range of Victron GX-connected peripherals. System configuration is handled through VEConfigure or the GX touch interface, and firmware updates are delivered over the air via VRM.\u003c\/p\u003e\n\n\u003cp\u003ePowerAssist is particularly useful in installations where the available AC supply (generator or shore power) is limited. The unit monitors AC input current and, when load demand approaches the set limit, draws the balance from the battery rather than tripping the supply. This allows a smaller generator to run a larger load profile without risk of overload. The ESS assistant enables grid-tied operation with configurable feed-in, self-consumption priority and scheduled charging from the grid.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP242306000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3000VA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Output\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e70A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Current Limit\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e32A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Frequency\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e50Hz \/ 60Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eTransfer Switch Time\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u0026lt;20ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIntegrated GX Device\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eYes (VenusOS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interfaces\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus, VE.Can, VE.Direct, USB, Ethernet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e20 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076051695\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid cabins and rural properties requiring a self-contained inverter, charger and monitoring solution.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations with 24V battery banks and shore power connection.\u003c\/li\u003e\n  \u003cli\u003eVehicle and mobile applications where 24V DC architecture is already in use.\u003c\/li\u003e\n  \u003cli\u003eGrid-tied battery storage systems using the ESS assistant for self-consumption optimisation.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems for critical loads requiring fast transfer from mains to inverter.\u003c\/li\u003e\n  \u003cli\u003eGenerator-assisted off-grid systems where PowerAssist is needed to manage limited AC input capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron MultiPlus-II 24\/3000\/70-32 230V GX inverter charger unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis unit must be installed by a qualified electrician or accredited installer. DC connections at 24V with large battery banks carry very high fault currents and must be fused and cabled correctly. For grid-connected ESS installations in the UK, the system must comply with G98 or G99 requirements depending on export capacity, and DNO notification or approval may be required. The integrated GX device requires a network connection (Ethernet or WiFi via USB adapter) for VRM portal access. Battery chemistry settings must be configured correctly before commissioning to avoid overcharging. Lithium battery integration may require a managed BMS with VE.Can or VE.Direct communication.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47391931695438,"sku":"PMP242306000","price":743.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/victron-multiplus-ii-24300070-32-230v-gx-pmp242306000-263651.webp?v=1747927498","url":"https:\/\/voltaconsolar.com\/products\/victron-multiplus-ii-24-3000-70-32-230v-gx","provider":"VoltaconSolar","version":"1.0","type":"link"}