{"product_id":"victron-multiplus-ii-48v-6kva-gx-inverter-charger","title":"Victron MultiPlus-II 48\/6k5\/100-50 230V GX - PMP482606000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus-II 48\/6000\/100-50 230V GX Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus-II 48\/6000\/100-50 230V GX is a combined inverter, battery charger and transfer switch with an integrated GX controller, designed for off-grid, hybrid and backup power installations. It operates on a 48V battery bank and delivers 6,000VA of continuous inverter output at 230V AC. The built-in GX device removes the need for a separate Cerbo GX or Color Control unit, making it well suited to space-constrained installations and system builds where monitoring and control need to be consolidated.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e6,000VA continuous inverter output with 48V DC input, suitable for substantial AC loads in off-grid and backup systems.\u003c\/li\u003e\n  \u003cli\u003eIntegrated GX controller provides built-in system monitoring, VRM portal connectivity and DVCC support without additional hardware.\u003c\/li\u003e\n  \u003cli\u003e100A battery charger with adaptive charge algorithm, supporting a wide range of battery chemistries including lithium and lead-acid variants.\u003c\/li\u003e\n  \u003cli\u003e50A AC input current limit on the shore or generator input, with PowerControl and PowerAssist functions to prevent overloading the AC source.\u003c\/li\u003e\n  \u003cli\u003eTransfer switch with a typical switchover time of 20ms, maintaining supply to connected loads during grid or generator interruptions.\u003c\/li\u003e\n  \u003cli\u003eSupports ESS (Energy Storage System) configuration for grid-tied self-consumption and backup applications.\u003c\/li\u003e\n  \u003cli\u003eSingle-phase 230V output, compatible with standard UK and European AC distribution.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus communication port for parallel and three-phase system expansion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II GX combines the full MultiPlus-II inverter charger with a GX monitoring device in a single enclosure. In practice, this means the unit can connect directly to the VRM online portal via Ethernet or Wi-Fi, log system data, and communicate with compatible BMS units and MPPT solar charge controllers over VE.Direct and VE.Can, all without a separate GX device. For installers working on residential or light commercial systems, this reduces wiring complexity and cabinet space requirements.\u003c\/p\u003e\n\n\u003cp\u003eThe 100A charger uses a three-stage adaptive algorithm and can be configured for lithium iron phosphate, gel, AGM and other battery types through VictronConnect or the GX interface. The 50A AC input limit, combined with PowerAssist, allows the unit to supplement a limited AC source (such as a small generator) with battery power when loads exceed what the source can supply alone. This is particularly useful in off-grid cabins, boats or sites where generator capacity is constrained.\u003c\/p\u003e\n\n\u003cp\u003eThe unit supports parallel operation for increased capacity and can be configured for three-phase output when used with two additional MultiPlus-II units. ESS configuration is supported for grid-connected installations where self-consumption optimisation or backup is required. For UK grid-connected use, compliance with G98 or G99 requirements will depend on the specific installation configuration and DNO approval.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP482606000\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e6,000VA continuous\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V single phase\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Current\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Current Limit\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e50A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input \/ Output\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V 50Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIntegrated GX Device\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eYes\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Ports\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus, VE.Direct, VE.Can, Ethernet, USB\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e29.5 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076066507\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and rural properties requiring a high-capacity inverter charger with integrated monitoring.\u003c\/li\u003e\n  \u003cli\u003eHybrid solar installations combining grid or generator input with battery storage and solar MPPT charge controllers.\u003c\/li\u003e\n  \u003cli\u003eESS installations for self-consumption optimisation and grid backup in domestic or light commercial settings.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle applications where a 48V battery bank and 230V AC output are required alongside remote monitoring.\u003c\/li\u003e\n  \u003cli\u003eGenerator-backed systems where PowerAssist is needed to supplement a limited AC source during peak load periods.\u003c\/li\u003e\n  \u003cli\u003eThree-phase system builds using multiple MultiPlus-II units in a master\/slave configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron MultiPlus-II 48\/6000\/100-50 230V GX inverter charger unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis unit operates at 48V DC and handles significant AC and DC currents. Installation must be carried out by a qualified electrician or MCS-accredited installer. The 29.5 kg weight requires appropriate mounting provisions. For grid-connected ESS configurations in the UK, the installer must confirm G98 or G99 compliance with the relevant DNO before energising. Battery type and charge parameters must be configured correctly before commissioning to avoid damage to the battery bank. Lithium battery installations require a compatible BMS with VE.Bus or VE.Can communication.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":55372045123918,"sku":"PMP482606000","price":845.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/PMP482606000_MultiPlus-II48_6k5_100-50230VGX3.jpg?v=1771942434","url":"https:\/\/voltaconsolar.com\/products\/victron-multiplus-ii-48v-6kva-gx-inverter-charger","provider":"VoltaconSolar","version":"1.0","type":"link"}