{"product_id":"victron-phoenix-inverter-12-500-230v-ve-direct-iec-disc","title":"Ph.Inv. 12\/500 230V VE.Direct IEC *If 0, order PIN121501110*","description":"\u003ch1 style=\"color: #f87c24;\"\u003ePhoenix Inverter 12\/500 230V VE.Direct IEC\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Phoenix 12\/500 is a 500VA pure sine wave inverter designed for 12V DC systems, converting battery power to 230V AC output. It suits off-grid installations, mobile applications and backup power setups where a compact, reliable inverter is needed. VE.Direct connectivity allows direct monitoring and control via compatible Victron devices.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e500VA continuous output with pure sine wave AC, suitable for sensitive electronics and motor loads.\u003c\/li\u003e\n  \u003cli\u003e12V DC input with 230V AC output via IEC socket, covering a wide range of standard appliances.\u003c\/li\u003e\n  \u003cli\u003eVE.Direct port enables communication with Victron monitoring equipment including the Color Control GX and Venus GX.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in protections cover low battery shutdown, overload, short circuit and over-temperature.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight form factor at 4.1 kg, suited to installations with limited space.\u003c\/li\u003e\n  \u003cli\u003eHigh efficiency design minimises battery drain during light load conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Phoenix 12\/500 operates from a 12V battery bank and delivers a clean 230V AC pure sine wave output. Pure sine wave output is important where loads include variable speed motors, medical equipment, audio equipment or any device with a switched-mode power supply. A modified sine wave inverter can cause problems with these load types; the Phoenix avoids that entirely.\u003c\/p\u003e\n\n\u003cp\u003eVE.Direct is Victron's point-to-point communication protocol. On this inverter it allows connection to a GX device, a PC running VictronConnect, or a dedicated VE.Direct to USB interface. This makes it straightforward to integrate the Phoenix 12\/500 into a monitored off-grid or mobile system without additional hardware complexity.\u003c\/p\u003e\n\n\u003cp\u003eThe IEC output socket is a standard C13-type connection, making it compatible with a wide range of appliances and extension leads. The inverter's protection circuitry handles low battery voltage cutoff automatically, protecting the battery bank from deep discharge damage.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN121501100\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eNominal DC Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e500VA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Direct\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Socket\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIEC (C13)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e4.1 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076047131\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid cabins and remote buildings powered by a 12V battery and solar array.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations requiring 230V AC from a 12V DC bank.\u003c\/li\u003e\n  \u003cli\u003eVehicle conversions including campervans and motorhomes.\u003c\/li\u003e\n  \u003cli\u003eBackup power for small office or domestic loads during grid outages.\u003c\/li\u003e\n  \u003cli\u003eTelecoms or instrumentation enclosures needing a monitored AC supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePhoenix Inverter 12\/500 230V VE.Direct IEC unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis inverter should be installed by a qualified electrician. DC wiring from the battery bank must be correctly rated and fused for the input current at 12V. Ensure adequate ventilation around the unit to prevent thermal shutdown under sustained load. For any solar-connected or grid-backup system, consult a qualified installer to confirm compliance with relevant wiring regulations.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59864584847694,"sku":"PIN121501100","price":102.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PIN121501100_-_Phoenix_Inverter_12-500_230V_VE.Direct_IEC.webp?v=1781187953","url":"https:\/\/voltaconsolar.com\/products\/victron-phoenix-inverter-12-500-230v-ve-direct-iec-disc","provider":"VoltaconSolar","version":"1.0","type":"link"}