{"product_id":"victron-phoenix-inverter-48-1200-230v-ve-direct-schuko","title":"Victron Phoenix Inverter 48\/1200 230V VE.Direct SCHUKO - PIN482121200","description":"\u003ch1 style=\"color: #f87c24;\"\u003ePhoenix Inverter 48\/1200 230V VE.Direct SCHUKO\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Phoenix Inverter 48\/1200 is a pure sine wave DC-to-AC inverter designed for off-grid and backup power applications. It converts 48V DC battery power to 230V AC at 1200VA continuous output, with a SCHUKO socket for direct appliance connection. VE.Direct connectivity allows monitoring and configuration via Victron's software ecosystem.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1200VA continuous output with pure sine wave AC, suitable for sensitive electronics and motor loads.\u003c\/li\u003e\n  \u003cli\u003e48V DC input with VE.Direct port for direct communication with Victron monitoring devices and the VictronConnect app.\u003c\/li\u003e\n  \u003cli\u003eSCHUKO output socket provides a standard European plug connection for immediate appliance use without additional wiring.\u003c\/li\u003e\n  \u003cli\u003eHigh peak power capacity handles inrush currents from motors, compressors and similar loads.\u003c\/li\u003e\n  \u003cli\u003eComprehensive protection including over-temperature, overload, low battery voltage shutdown and short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003eLow idle power consumption makes it practical for installations where the inverter runs continuously or for extended periods.\u003c\/li\u003e\n  \u003cli\u003eCompact and wall-mountable design suited to vehicle, marine, off-grid cabin and backup power installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Phoenix 48\/1200 operates from a 48V battery bank and delivers a clean, stable 230V AC sine wave output. Pure sine wave output is important where the load includes variable-speed motors, medical equipment, audio equipment or any device with a switched-mode power supply. A modified sine wave inverter will cause problems with these load types; the Phoenix avoids that entirely.\u003c\/p\u003e\n\n\u003cp\u003eVE.Direct is Victron's point-to-point serial communication interface. On this inverter it enables connection to the Victron GX device range, the VE.Direct to USB interface, or direct Bluetooth monitoring via the VE.Direct Bluetooth Smart dongle. This allows real-time monitoring of AC output, battery state and alarm conditions without additional shunts or external meters. For installers building a Victron-based system, this integration is straightforward and well-supported.\u003c\/p\u003e\n\n\u003cp\u003eThe SCHUKO socket format means the unit can be used immediately with standard European plugs. For installations requiring hardwired AC output, Victron also produces variants with terminal connections. At 6.9 kg, the unit is manageable for a single installer and includes mounting provisions for a fixed installation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN482121200\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e1200VA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Direct\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Socket\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSCHUKO\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e6.9 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076056911\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid cabins and remote buildings powered by a 48V battery bank.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations requiring 230V AC from a 48V DC system.\u003c\/li\u003e\n  \u003cli\u003eVehicle conversions (campervan, expedition vehicle) with a 48V house battery.\u003c\/li\u003e\n  \u003cli\u003eBackup power for sensitive equipment such as routers, NAS devices or medical apparatus.\u003c\/li\u003e\n  \u003cli\u003eTelecoms and industrial enclosures needing a compact, monitored AC supply from a DC battery system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePhoenix Inverter 48\/1200 230V VE.Direct SCHUKO unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis inverter operates at 48V DC and must be connected to a correctly fused and rated DC supply. DC wiring at this current level carries significant fault energy; connections should be made by a qualified electrician or experienced installer. The unit is not grid-tied and does not require G98 or G99 notification. For any installation in a domestic or commercial property, work on the AC side must comply with BS 7671 wiring regulations. Ensure the battery bank is appropriately sized for the intended load and that DC cable sizing accounts for voltage drop at full output current.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59864589435214,"sku":"PIN482121200","price":245.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PIN482121200_-_Phoenix_Inverter_48-1200_230V_VE.Direct_SCHUKO.webp?v=1781187974","url":"https:\/\/voltaconsolar.com\/products\/victron-phoenix-inverter-48-1200-230v-ve-direct-schuko","provider":"VoltaconSolar","version":"1.0","type":"link"}