{"product_id":"victron-phoenix-inverter-48-250-230v-ve-direct-iec","title":"Victron Phoenix Inverter 48\/250 230V VE.Direct IEC - PIN481251100","description":"\u003ch1 style=\"color: #f87c24;\"\u003ePhoenix Inverter 48\/250 230V VE.Direct IEC\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Phoenix Inverter 48\/250 is a compact, pure sine wave inverter designed for 48V battery systems, delivering 250VA continuous output at 230V AC. It is aimed at installers and system integrators who need a reliable DC-to-AC conversion stage in off-grid, marine, vehicle or backup power applications where load demands are modest and space is limited.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePure sine wave output at 230V AC, suitable for sensitive electronics and motor loads.\u003c\/li\u003e\n  \u003cli\u003e48V DC input with VE.Direct communication port for monitoring and integration with Victron GX devices and VictronConnect.\u003c\/li\u003e\n  \u003cli\u003eIEC AC output connector for straightforward, standardised wiring.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 2.6 kg, making it practical for installations with restricted space.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in protections covering low battery voltage shutdown, overload and over-temperature, reducing the risk of damage in unattended installations.\u003c\/li\u003e\n  \u003cli\u003eConfigurable via VictronConnect app over Bluetooth (with optional dongle) or direct VE.Direct USB interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Phoenix 48\/250 converts 48V DC battery power to a clean 230V AC pure sine wave output. Pure sine wave output matters when powering equipment with switch-mode power supplies, variable speed motors or audio and medical devices, all of which can behave unpredictably or be damaged by modified sine wave inverters. At 250VA continuous, this unit is sized for smaller loads: lighting circuits, instrumentation, small appliances or control systems rather than high-draw equipment.\u003c\/p\u003e\n\n\u003cp\u003eThe VE.Direct port is a key practical feature. It allows the inverter to communicate with Victron's GX range of system monitors (such as the Cerbo GX), enabling remote monitoring, on\/off control and data logging within a wider Victron energy system. This makes the Phoenix 48\/250 a straightforward fit in any Victron-based off-grid or backup installation where a low-power AC output is needed alongside battery management and monitoring.\u003c\/p\u003e\n\n\u003cp\u003eThe IEC output socket provides a standardised connection point, keeping the installation clean and compliant. The unit's protections (low voltage, overload, over-temperature) are automatic and do not require manual reset in most cases, which is relevant for installations that run unattended for extended periods.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN481251100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e250VA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Direct\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Connector\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIEC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e2.6 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076056744\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid cabins, sheds or outbuildings where a 48V battery bank is already in place.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations requiring a small 230V AC output from a 48V DC system.\u003c\/li\u003e\n  \u003cli\u003eVehicle conversions (campervan, motorhome) with 48V lithium or lead-acid battery systems.\u003c\/li\u003e\n  \u003cli\u003eBackup power for low-draw critical loads such as routers, alarm systems or instrumentation panels.\u003c\/li\u003e\n  \u003cli\u003eVictron system integrations where a compact inverter output is needed alongside GX monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePhoenix Inverter 48\/250 230V VE.Direct IEC unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis inverter should be installed by a qualified electrician or experienced system integrator. DC connections at 48V carry significant fault current and must be fused appropriately close to the battery. The AC IEC output is not intended for direct connection to a fixed wiring installation without appropriate isolation and protection. For any installation forming part of a grid-connected or building electrical system, work must comply with BS 7671 (IET Wiring Regulations) and be carried out by a competent person. VE.Direct connectivity requires a compatible cable or interface adapter, sold separately.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863718297934,"sku":"PIN481251100","price":70.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PIN481251100_-_Phoenix_Inverter_48-250_230V_VE.Direct_IEC.webp?v=1781183694","url":"https:\/\/voltaconsolar.com\/products\/victron-phoenix-inverter-48-250-230v-ve-direct-iec","provider":"VoltaconSolar","version":"1.0","type":"link"}