{"product_id":"victron-phoenix-inverter-48-800-230v-ve-direct-schuko","title":"Victron Phoenix Inverter 48\/800 230V VE.Direct SCHUKO - PIN481801200","description":"\u003ch1 style=\"color: #f87c24;\"\u003ePhoenix Inverter 48\/800 230V VE.Direct SCHUKO\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Phoenix Inverter 48\/800 is a pure sine wave inverter designed for 48V DC battery systems, delivering 800VA of continuous AC output at 230V. It is aimed at off-grid installations, mobile applications and backup power setups where a clean, stable AC supply is required from a battery bank. The SCHUKO output socket makes it ready for direct use with standard European plugs without additional wiring.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePure sine wave output ensures compatibility with sensitive electronics, motors and appliances.\u003c\/li\u003e\n  \u003cli\u003e48V DC input with 800VA continuous output at 230V AC.\u003c\/li\u003e\n  \u003cli\u003eVE.Direct communication port allows monitoring and configuration via Victron's GX devices, MPPT Solar Chargers and the VictronConnect app over Bluetooth (with optional dongle).\u003c\/li\u003e\n  \u003cli\u003eSCHUKO output socket fitted as standard, suitable for direct connection of European-standard plugged loads.\u003c\/li\u003e\n  \u003cli\u003ePowerControl and PowerAssist functions allow the inverter to supplement an AC source rather than replace it, preventing overload of a limited supply.\u003c\/li\u003e\n  \u003cli\u003eIntegrated battery protection with configurable low voltage shutdown to prevent deep discharge damage.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight design at 5.8 kg, suitable for installation in confined spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Phoenix 48\/800 operates from a 48V battery bank and produces a pure sine wave output, which is the correct waveform for running inductive loads such as motors, compressors and any equipment with a switched-mode power supply. Modified sine wave inverters can cause problems with these load types; the Phoenix avoids that entirely.\u003c\/p\u003e\n\n\u003cp\u003eVE.Direct connectivity is a key practical feature for professional installations. It allows the inverter to communicate with Victron GX devices (such as the Cerbo GX) for system-level monitoring, data logging and remote management via the VRM portal. It also enables direct configuration and live monitoring through the VictronConnect app when used with a VE.Direct Bluetooth Smart dongle. This makes the Phoenix 48\/800 a straightforward fit into a wider Victron system architecture.\u003c\/p\u003e\n\n\u003cp\u003eThe SCHUKO socket output means the unit can be deployed quickly in applications where a single plugged load needs to be powered from a 48V battery, without requiring a hardwired AC distribution board. For installations requiring hardwired output, the terminal block connection option is available on other variants in the Phoenix range.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN481801200\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e800 VA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Socket\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSCHUKO\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Direct\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e5.8 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076056874\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid cabins and outbuildings powered by a 48V battery bank.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations requiring a 230V AC supply from a 48V house bank.\u003c\/li\u003e\n  \u003cli\u003eVehicle conversions (motorhomes, vans) with 48V electrical systems.\u003c\/li\u003e\n  \u003cli\u003eBackup power for single loads or small circuits during mains outages.\u003c\/li\u003e\n  \u003cli\u003eTelecoms and remote monitoring enclosures requiring a reliable AC supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Phoenix Inverter 48\/800 230V VE.Direct SCHUKO unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation should be carried out by a qualified electrician or accredited installer familiar with DC battery systems and low-voltage AC wiring. The inverter must be connected to a 48V battery bank with appropriately rated DC cabling and fusing. Ensure adequate ventilation around the unit to prevent thermal shutdown. This inverter is not grid-tied and does not require G98 or G99 notification. For integration into a wider Victron system, a VE.Direct cable or VE.Direct Bluetooth Smart dongle is required separately.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59864597954894,"sku":"PIN481801200","price":185.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_PIN481801200_-_Phoenix_Inverter_48-800_230V_VE.Direct_SCHUKO.webp?v=1781188004","url":"https:\/\/voltaconsolar.com\/products\/victron-phoenix-inverter-48-800-230v-ve-direct-schuko","provider":"VoltaconSolar","version":"1.0","type":"link"}