{"product_id":"victron-shunt-500a-50mv","title":"Victron Shunt 500A\/50mV - SHU500050100","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Shunt 500A\/50mV\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 500A\/50mV shunt is a precision current measurement component used in battery monitoring and energy management systems. It is designed for use with compatible Victron battery monitors and BMV series devices, allowing accurate measurement of charge and discharge current in 12V, 24V and 48V DC systems. Suitable for solar, off-grid, marine and vehicle installations where reliable current sensing is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 500A continuous with a 50mV voltage drop at full rated current, giving a shunt resistance of 0.1 milliohms.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron BMV battery monitors and other devices that accept a 50mV shunt input signal.\u003c\/li\u003e\n  \u003cli\u003eCompact and robust construction suitable for installation in battery enclosures, distribution boards and switchgear panels.\u003c\/li\u003e\n  \u003cli\u003eProvides the current measurement reference point for accurate state-of-charge calculations in battery monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 0.3kg, making it straightforward to mount in space-constrained installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA shunt works by inserting a known, very low resistance into the main current path. The voltage drop across it is proportional to the current flowing through it. At 500A, this shunt produces exactly 50mV, which the connected battery monitor reads and converts into an accurate current figure. The 50mV standard is widely used across the industry, so this shunt is also compatible with third-party monitors that accept a 50mV input.\u003c\/p\u003e\n\n\u003cp\u003eThe 500A rating makes this shunt appropriate for battery banks and systems where peak charge or discharge currents can be substantial, such as large inverter installations, high-capacity lithium or AGM battery banks, and solar systems with significant load or charging current. Sizing the shunt correctly matters: running a shunt continuously above its rated current will cause measurement drift and potential damage, so confirm your system's maximum expected current before selecting this rating.\u003c\/p\u003e\n\n\u003cp\u003eThis shunt is the standard replacement or additional shunt supplied by Victron for use with their BMV-700, BMV-702, BMV-712 and SmartShunt product lines where a separate shunt is required. It connects via the dedicated shunt terminals on those monitors using the supplied cable harness from the monitor kit.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: SHU500050100\u003c\/li\u003e\n  \u003cli\u003eRated current: 500A\u003c\/li\u003e\n  \u003cli\u003eVoltage drop at rated current: 50mV\u003c\/li\u003e\n  \u003cli\u003eShunt resistance: 0.1 milliohms\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.3kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076026211\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBattery current monitoring in off-grid solar power systems.\u003c\/li\u003e\n  \u003cli\u003eCurrent sensing in marine and narrowboat 12V or 24V house battery banks.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and campervan leisure battery monitoring installations.\u003c\/li\u003e\n  \u003cli\u003eReplacement or spare shunt for Victron BMV battery monitor installations.\u003c\/li\u003e\n  \u003cli\u003eAny DC system requiring accurate current measurement up to 500A continuous.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron Energy 500A\/50mV shunt\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe shunt must be installed in the negative main cable between the battery bank negative terminal and the system negative busbar, with all loads and chargers connected on the system side. Only the battery negative should connect directly to the shunt battery terminal. Incorrect wiring will produce inaccurate readings. For systems forming part of a grid-connected or high-voltage installation, work should be carried out by a qualified electrician or MCS-accredited installer. Ensure all connections are torqued correctly and that the shunt is rated for the maximum continuous current in your system before installation.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59856061432142,"sku":"SHU500050100","price":17.83,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_SHU500050100_-_Shunt_500A-50mV.webp?v=1781102049","url":"https:\/\/voltaconsolar.com\/products\/victron-shunt-500a-50mv","provider":"VoltaconSolar","version":"1.0","type":"link"}