{"product_id":"victron-skylla-i-24-80-3-230v-battery-charger","title":"Victron Skylla-i 24\/80(3) 230V - SKI024080002","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Skylla-i 24\/80(3) 230V Battery Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Skylla-i 24\/80(3) is a three-output, 24V 80A mains-powered battery charger designed for professional and commercial applications. It is built for demanding environments where reliable, high-current charging is required across multiple battery banks simultaneously. Typical users include marine, vehicle, industrial and off-grid installations where a single charger must serve several independent battery systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e80A total output at 24V across three independently controlled output channels, allowing simultaneous charging of separate battery banks.\u003c\/li\u003e\n  \u003cli\u003eAdaptive charging algorithm with automatic battery detection adjusts the charge profile to suit the connected battery type and condition.\u003c\/li\u003e\n  \u003cli\u003eSingle-phase 230V AC input makes it compatible with standard shore power, generator supply or mains connections.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in VE.Bus communication port enables integration with Victron system monitoring, remote control panels and GX devices.\u003c\/li\u003e\n  \u003cli\u003eTemperature-compensated charging via an optional sensor input ensures accurate charge voltage across varying ambient conditions.\u003c\/li\u003e\n  \u003cli\u003eConfigurable charge algorithms via VictronConnect or a remote panel, supporting flooded, gel, AGM and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003eCompact, wall-mountable enclosure with a weight of 8kg, suitable for permanent installation in engine rooms, battery compartments and plant rooms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Skylla-i 24\/80(3) delivers 80A of charge current at 24V from a 230V AC supply, split across three output channels. Each output can be configured independently, which is particularly useful in applications where a starter battery, a service bank and an auxiliary system need to be maintained from a single charger. The three-output configuration avoids the need for separate chargers and the associated wiring complexity.\u003c\/p\u003e\n\n\u003cp\u003eVE.Bus connectivity sets the Skylla-i apart from basic chargers. It allows the unit to communicate directly with Victron GX devices, Color Control panels and system monitors, giving installers full visibility of charge state, battery voltage and current from a central point. This is especially relevant in professional marine and vehicle installations where system oversight is a requirement rather than an option.\u003c\/p\u003e\n\n\u003cp\u003eThe adaptive charging algorithm monitors battery behaviour during each charge cycle and adjusts the absorption time accordingly. This means a deeply discharged battery receives a full, extended absorption phase, while a battery that is already well maintained will complete the cycle more quickly. Over time this approach reduces stress on the battery and extends service life without requiring manual intervention.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKI024080002\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Current\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e80A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eNumber of Outputs\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V single phase\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076026235\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMarine vessels requiring simultaneous charging of starter, service and bow thruster battery banks from shore power.\u003c\/li\u003e\n  \u003cli\u003eCommercial vehicles and coaches where multiple 24V battery systems need to be maintained during layover periods.\u003c\/li\u003e\n  \u003cli\u003eOff-grid cabins and plant rooms with a 230V generator supply and multiple battery banks.\u003c\/li\u003e\n  \u003cli\u003eIndustrial UPS and backup power systems requiring a high-current, monitored 24V charger with remote oversight capability.\u003c\/li\u003e\n  \u003cli\u003eVictron-based energy systems where VE.Bus integration with a GX device or Color Control panel is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Skylla-i 24\/80(3) 230V battery charger (1 unit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe Skylla-i 24\/80(3) must be installed by a qualified electrician. The unit connects to a 230V single-phase AC supply and delivers up to 80A DC output, requiring correctly rated DC cabling, fusing and battery connections for each output channel. Battery chemistry and charge parameters should be configured before commissioning using VictronConnect or a compatible Victron remote panel. If installed aboard a vessel, wiring must comply with applicable marine electrical standards. Temperature sensor installation is recommended in environments subject to significant thermal variation.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59866759004494,"sku":"SKI024080002","price":992.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_SKI024080002_-_Skylla-i_24-80_3_230V.webp?v=1781200500","url":"https:\/\/voltaconsolar.com\/products\/victron-skylla-i-24-80-3-230v-battery-charger","provider":"VoltaconSolar","version":"1.0","type":"link"}