{"product_id":"victron-skylla-tg-24-100-1plus1-gl-120-240v","title":"Victron Skylla-TG 24\/100(1+1) GL 120-240V - SDTG2401003","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Skylla-TG 24\/100 (1+1) GL 120-240V Battery Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Skylla-TG 24\/100 (1+1) GL is a high-power 24V battery charger rated at 100A, designed for demanding professional and industrial applications. The (1+1) configuration provides a dedicated output for a starter battery in addition to the main bank, making it well suited to marine, vehicle and generator installations where multiple battery banks must be maintained simultaneously. It accepts a wide AC input range of 120 to 240V, allowing use across different supply voltages.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100A output at 24V nominal, providing high charge current for large battery banks.\u003c\/li\u003e\n  \u003cli\u003e(1+1) dual output: main bank output plus a separate trickle output for a starter or auxiliary battery.\u003c\/li\u003e\n  \u003cli\u003eWide AC input voltage range of 120 to 240V, compatible with both North American and European supply standards.\u003c\/li\u003e\n  \u003cli\u003eGL certification indicates compliance with relevant international safety standards for the charger.\u003c\/li\u003e\n  \u003cli\u003eDesigned for continuous-duty industrial and marine use, with a robust aluminium housing suited to fixed installations.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron's VE.Bus and monitoring ecosystem, allowing integration with system panels and remote monitoring where supported.\u003c\/li\u003e\n  \u003cli\u003eAdaptive four-stage charge algorithm (bulk, absorption, float, storage) to protect and condition lead-acid battery banks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Skylla-TG range sits at the top of Victron's charger lineup for fixed, high-current applications. The 24\/100 model delivers up to 100A into a 24V battery bank, which is sufficient to charge large lead-acid banks found on commercial vessels, heavy vehicles, off-grid systems and industrial UPS installations. The (1+1) designation means the unit has a primary high-current output for the main battery bank and a secondary output that maintains a starter or auxiliary battery independently, without requiring a separate charger.\u003c\/p\u003e\n\n\u003cp\u003eThe wide 120 to 240V AC input makes this charger practical for installations where the supply voltage may vary or where the same unit needs to operate in different countries. The GL mark confirms the unit has been assessed to internationally recognised safety standards. At 9.85kg, the unit is intended for permanent panel or bulkhead mounting rather than portable use.\u003c\/p\u003e\n\n\u003cp\u003eVictron's adaptive charge algorithm adjusts absorption time based on the bulk charge duration, which reduces stress on batteries that are already partially charged. The storage mode drops the float voltage further when the battery has been fully charged and left on charge for an extended period, reducing electrolyte loss and plate corrosion over time.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: SDTG2401003\u003c\/li\u003e\n  \u003cli\u003eOutput voltage: 24V nominal\u003c\/li\u003e\n  \u003cli\u003eOutput current: 100A\u003c\/li\u003e\n  \u003cli\u003eOutput configuration: (1+1) dual output\u003c\/li\u003e\n  \u003cli\u003eAC input voltage: 120 to 240V\u003c\/li\u003e\n  \u003cli\u003eCertification: GL\u003c\/li\u003e\n  \u003cli\u003eWeight: 9.85kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076025795\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial and leisure marine vessels requiring simultaneous charging of main and starter battery banks.\u003c\/li\u003e\n  \u003cli\u003eOff-grid and backup power systems with large 24V lead-acid battery banks.\u003c\/li\u003e\n  \u003cli\u003eHeavy vehicles, coaches and motorhomes with high-capacity house battery installations.\u003c\/li\u003e\n  \u003cli\u003eIndustrial UPS and standby power systems requiring continuous-duty high-current charging.\u003c\/li\u003e\n  \u003cli\u003eGenerator-fed charging systems where AC supply voltage may vary between 120V and 240V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Skylla-TG 24\/100 (1+1) GL charger unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe Skylla-TG 24\/100 should be installed by a qualified electrician or accredited marine\/electrical engineer. The unit operates at mains voltage and connects to large battery banks, both of which present serious shock and short-circuit hazards if handled incorrectly. Ensure the AC supply is correctly fused and that DC cabling is rated for the full 100A output current. Battery bank connections must be made with appropriately sized cable and correctly rated fusing or circuit protection on the DC side. For marine installations, follow the relevant flag state and classification society requirements. Consult the Victron Skylla-TG installation manual for full wiring diagrams, ventilation requirements and configuration instructions before commissioning.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":60190998790478,"sku":"SDTG2401003","price":1243.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_SDTG2401003_-_Skylla-TG_24-100_1_1_GL_120-240V.webp?v=1784715827","url":"https:\/\/voltaconsolar.com\/products\/victron-skylla-tg-24-100-1plus1-gl-120-240v","provider":"VoltaconSolar","version":"1.0","type":"link"}