{"product_id":"victron-skylla-tg-24-100-3-phase-400v-charger","title":"Victron Skylla-TG 24\/100(1+1) 3-Phase 400V - STG024100300","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Skylla-TG 24\/100 (1+1) 3-Phase 400V Battery Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Skylla-TG 24\/100 (1+1) is a high-power three-phase battery charger designed for 24V battery systems requiring up to 100A of charge current. Built for demanding industrial, marine and off-grid applications, it accepts a 3-phase 400V AC input and is suited to environments where reliability and continuous duty operation are essential.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100A charge output for 24V battery banks, with a (1+1) configuration supporting parallel or redundant operation.\u003c\/li\u003e\n  \u003cli\u003e3-phase 400V AC input, making it compatible with industrial and commercial power supplies.\u003c\/li\u003e\n  \u003cli\u003eHigh-power charger category, designed for continuous duty in demanding installations.\u003c\/li\u003e\n  \u003cli\u003eCompact and robust metal enclosure suitable for fixed installation in plant rooms, vessels and off-grid power systems.\u003c\/li\u003e\n  \u003cli\u003ePart of the Victron Skylla-TG range, which is designed for professional installation in high-demand charging applications.\u003c\/li\u003e\n  \u003cli\u003eWeight of 23.45kg reflects a heavy-duty internal transformer and power stage construction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Skylla-TG range uses a transformer-based design rather than a switched-mode topology. This approach provides inherent galvanic isolation and a high degree of tolerance to poor or unstable input power quality, which is a practical advantage in generator-fed or industrial grid environments. The 3-phase 400V input distributes load evenly across phases, reducing peak current draw and making the unit well suited to installations where single-phase loading is restricted.\u003c\/p\u003e\n\n\u003cp\u003eThe (1+1) designation indicates that the unit contains two independent charger modules sharing a single enclosure. This allows the charger to operate in a parallel configuration for increased output, or in a redundant configuration where one module continues to charge the battery if the other develops a fault. For critical systems such as telecom backup, marine propulsion support or industrial UPS applications, this built-in redundancy is a meaningful operational advantage.\u003c\/p\u003e\n\n\u003cp\u003eAt 100A output into a 24V bank, this charger is appropriate for large battery installations including forklift batteries, large lead-acid standby banks and substantial off-grid storage systems. The 24V nominal voltage is common in heavy commercial and marine DC systems where higher current capacity is required compared to 48V equivalents.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e STG024100300\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput voltage:\u003c\/strong\u003e 24V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput current:\u003c\/strong\u003e 100A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e (1+1) dual module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC input:\u003c\/strong\u003e 3-phase 400V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 23.45kg\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGTIN:\u003c\/strong\u003e 8719076026686\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge lead-acid or gel battery banks in industrial standby and UPS systems.\u003c\/li\u003e\n  \u003cli\u003eMarine vessels with 24V DC systems and three-phase shore power connections.\u003c\/li\u003e\n  \u003cli\u003eOff-grid power installations with generator-based charging and large battery storage.\u003c\/li\u003e\n  \u003cli\u003eTelecom and critical infrastructure backup power where charger redundancy is required.\u003c\/li\u003e\n  \u003cli\u003eForklift and electric vehicle battery charging in commercial premises with 3-phase supply.\u003c\/li\u003e\n  \u003cli\u003eRenewable energy systems with large 24V battery banks requiring high charge current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Skylla-TG 24\/100 (1+1) 3-Phase 400V charger unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis charger must be installed by a qualified electrician. Connection to a 3-phase 400V supply requires compliance with current UK and EU wiring regulations, and appropriate upstream protection must be fitted. The unit weighs 23.45kg and requires secure, ventilated mounting in a fixed installation. Battery connections should be made in accordance with the battery manufacturer's specifications and relevant DC wiring standards. Do not install in locations exposed to water ingress unless the enclosure rating has been confirmed as suitable for the environment.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59866758512974,"sku":"STG024100300","price":1575.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_STG024100300_-_Skylla-TG_24-100_1_1_3-Phase_400V.webp?v=1781200470","url":"https:\/\/voltaconsolar.com\/products\/victron-skylla-tg-24-100-3-phase-400v-charger","provider":"VoltaconSolar","version":"1.0","type":"link"}