{"product_id":"victron-skylla-tg-24-30-dual-output-120-240v","title":"Victron Skylla-TG 24\/30(1+1) 120-240V - SDTG2400301","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Skylla-TG 24\/30 (1+1) 120-240V Battery Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Skylla-TG 24\/30 (1+1) is a high-power, transformer-based battery charger designed for 24V battery systems. It accepts a wide AC input range of 120 to 240V, making it suitable for use across different mains supplies and generator outputs. The (1+1) configuration provides a dedicated output for a starter battery in addition to the main bank, which is a practical requirement in many marine, vehicle and industrial installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e30A output for 24V battery systems with a separate (1+1) output for simultaneous starter battery charging.\u003c\/li\u003e\n  \u003cli\u003eWide AC input voltage range of 120 to 240V accommodates varying mains and generator supplies without manual adjustment.\u003c\/li\u003e\n  \u003cli\u003eTransformer-based design provides galvanic isolation between AC input and DC output, an important safety requirement in many marine and vehicle installations.\u003c\/li\u003e\n  \u003cli\u003eHigh-power charger category, built for continuous duty in demanding environments.\u003c\/li\u003e\n  \u003cli\u003eVictron's adaptive charge algorithm adjusts the charge profile to suit battery condition, reducing the risk of overcharging or undercharging.\u003c\/li\u003e\n  \u003cli\u003eSKU: SDTG2400301 | GTIN: 8719076025719\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Skylla-TG range uses a transformer-based topology rather than a switched-mode design. This provides true galvanic isolation, which is a regulatory and practical requirement in many marine, vehicle and off-grid installations where DC and AC grounds must be kept separate. The transformer construction also makes the charger tolerant of poor-quality AC input, including generator power with voltage fluctuations or harmonic distortion.\u003c\/p\u003e\n\n\u003cp\u003eThe (1+1) output configuration means the charger manages two separate DC outputs simultaneously. The primary output delivers 30A to the main battery bank, while the secondary output maintains a starter or auxiliary battery independently. Both outputs are managed by the charger's control system, so neither battery is neglected when the charger is running.\u003c\/p\u003e\n\n\u003cp\u003eThe 120 to 240V AC input range means the same unit can be used on North American 120V supplies, European 230V mains, or typical generator outputs without any manual voltage selection. This makes the Skylla-TG 24\/30 (1+1) a practical choice for equipment that moves between different AC supply environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSDTG2400301\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Current (Main)\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e30A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Configuration\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e(1+1) dual output\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Voltage Range\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e120 to 240V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCharger Type\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eTransformer-based (galvanic isolation)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e5.4 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076025719\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMarine vessels requiring galvanically isolated battery charging for main and starter banks.\u003c\/li\u003e\n  \u003cli\u003eCommercial vehicles, coaches and motorhomes with 24V house battery systems and a separate starter battery.\u003c\/li\u003e\n  \u003cli\u003eOff-grid cabins and industrial sites using generator power with variable AC output voltage.\u003c\/li\u003e\n  \u003cli\u003eTelecom and industrial backup power systems requiring reliable 24V float and absorption charging.\u003c\/li\u003e\n  \u003cli\u003eInstallations where the AC supply may switch between 120V and 240V sources.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Skylla-TG 24\/30 (1+1) 120-240V battery charger unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation should be carried out by a qualified electrician or marine electrical engineer familiar with battery charging systems. The charger must be connected to a correctly rated AC supply with appropriate overcurrent protection. DC connections to the battery bank should be sized to handle the full output current. In marine installations, verify that the galvanic isolation meets the requirements of the relevant classification society or national standard. Ensure adequate ventilation around the unit during operation.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863720984910,"sku":"SDTG2400301","price":501.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_SDTG2400301_-_Skylla-TG_24-30_1_1_120-240V.webp?v=1781183723","url":"https:\/\/voltaconsolar.com\/products\/victron-skylla-tg-24-30-dual-output-120-240v","provider":"VoltaconSolar","version":"1.0","type":"link"}