{"product_id":"victron-skylla-tg-24-50-dual-output-gl","title":"Victron Skylla-TG 24\/50(1+1) GL 120-240V - SDTG2400503","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Skylla-TG 24\/50 (1+1) GL 120-240V Battery Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Skylla-TG 24\/50 is a high-power professional battery charger designed for 24V battery systems, delivering up to 50A of charge current. Built for demanding commercial, marine, and industrial applications, it accepts a wide AC input range of 120 to 240V and features a (1+1) output configuration for flexible battery bank management.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e50A charge output for 24V battery systems, suitable for large battery banks in professional installations.\u003c\/li\u003e\n  \u003cli\u003e(1+1) dual output configuration allows simultaneous charging of two separate battery banks from a single unit.\u003c\/li\u003e\n  \u003cli\u003eWide AC input voltage range of 120 to 240V makes the unit compatible with a broad range of generator and shore power supplies.\u003c\/li\u003e\n  \u003cli\u003eGL certification confirms compliance with relevant international safety standards for marine and industrial use.\u003c\/li\u003e\n  \u003cli\u003eAdaptive multi-stage charging algorithm adjusts charge profile based on battery condition to maximise battery life.\u003c\/li\u003e\n  \u003cli\u003eTemperature-compensated charging adjusts output voltage relative to ambient temperature, protecting batteries in variable environments.\u003c\/li\u003e\n  \u003cli\u003eRobust aluminium housing rated for professional installation in demanding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Skylla-TG range is Victron's high-power transformer-based charger series, designed where reliability and continuous duty performance are required. The 24\/50 model outputs 50A into a 24V bank, making it well suited to larger battery systems found on commercial vessels, vehicles, and off-grid installations. The transformer-based design provides galvanic isolation between the AC input and DC output, which is a practical requirement in many marine and industrial environments where ground loops or stray current corrosion are a concern.\u003c\/p\u003e\n\n\u003cp\u003eThe (1+1) output topology provides a primary output for the main battery bank and a secondary output for a separate service or starter battery. Both outputs are managed independently, so each bank receives the correct charge profile without interference from the other. This removes the need for a separate battery-to-battery charger or combiner relay in many installations.\u003c\/p\u003e\n\n\u003cp\u003eThe wide 120 to 240V AC input range means the Skylla-TG 24\/50 operates correctly on both North American and European shore power, as well as on most generator outputs. This makes it a practical choice for vessels and vehicles that operate across different regions or rely on variable generator supplies.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSDTG2400503\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCharge Current\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e50A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Configuration\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e(1+1) dual output\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e120 to 240V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCertification\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGL\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e5.4 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076025757\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial and leisure marine vessels requiring shore power battery charging with galvanic isolation.\u003c\/li\u003e\n  \u003cli\u003eHeavy vehicles, coaches, and motorhomes with large 24V battery banks and separate starter batteries.\u003c\/li\u003e\n  \u003cli\u003eOff-grid cabins and industrial sites using generator power as the primary AC source.\u003c\/li\u003e\n  \u003cli\u003eTelecom and backup power installations requiring reliable continuous-duty battery charging.\u003c\/li\u003e\n  \u003cli\u003eMulti-bank battery systems where independent charge management of two banks is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Skylla-TG 24\/50 (1+1) GL battery charger unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation should be carried out by a qualified electrician or marine electrical engineer familiar with DC battery systems and AC mains wiring. Ensure the AC supply is correctly fused and that DC cabling is sized to handle 50A continuous current with appropriate overcurrent protection on each output. For marine installations, follow the relevant standards for onboard electrical systems. The (1+1) output should be wired to separate battery banks; do not parallel the two outputs. Verify battery chemistry compatibility before connecting, as charge voltage settings must match the battery type in use.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59866758742350,"sku":"SDTG2400503","price":661.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_SDTG2400503_-_Skylla-TG_24-50_1_1_GL_120-240V.webp?v=1781200483","url":"https:\/\/voltaconsolar.com\/products\/victron-skylla-tg-24-50-dual-output-gl","provider":"VoltaconSolar","version":"1.0","type":"link"}