{"product_id":"victron-smartsolar-mppt-250-70-mc4-ve-can","title":"Victron SmartSolar MPPT 250\/70-MC4 VE.Can - SCC125070521","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron SmartSolar MPPT 250\/70-MC4 VE.Can Solar Charge Controller\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron SmartSolar MPPT 250\/70-MC4 VE.Can is a high-voltage solar charge controller designed for larger off-grid, marine and commercial installations. It accepts a maximum PV open-circuit voltage of 250V and delivers up to 70A of charge current, with integrated MC4 connectors for direct panel string connection and VE.Can for network integration into Victron systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaximum PV open-circuit voltage of 250V, suitable for longer series string configurations.\u003c\/li\u003e\n  \u003cli\u003e70A maximum charge current, supporting substantial battery bank charging from solar.\u003c\/li\u003e\n  \u003cli\u003eIntegrated MC4 connectors on the PV input, removing the need for separate MC4 adaptor cables.\u003c\/li\u003e\n  \u003cli\u003eVE.Can port enables integration with the Victron GX device ecosystem for full system monitoring and control.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Bluetooth via the VictronConnect app for wireless configuration, monitoring and firmware updates.\u003c\/li\u003e\n  \u003cli\u003eAdvanced MPPT algorithm with rapid maximum power point tracking, including under variable and partial shading conditions.\u003c\/li\u003e\n  \u003cli\u003eSupports multiple battery chemistries: lithium-ion, AGM, gel, flooded and user-defined custom profiles.\u003c\/li\u003e\n  \u003cli\u003eProgrammable relay output for load control, generator start or general alarm functions.\u003c\/li\u003e\n  \u003cli\u003eNetworked charging via VE.Can allows synchronisation with other Victron charge sources for balanced battery management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe SmartSolar MPPT 250\/70-MC4 VE.Can sits at the higher end of Victron's MPPT range. The 250V PV input rating allows installers to wire more panels in series, which reduces cable losses and is particularly useful on larger roof arrays or ground-mount systems where panel strings are run over longer distances. The 70A output is sufficient to charge 12V, 24V and 48V battery banks, with the controller automatically detecting the battery voltage on first connection.\u003c\/p\u003e\n\n\u003cp\u003eThe VE.Can interface is the key differentiator for professional system builds. It connects directly to a Victron Cerbo GX or other GX device, enabling full telemetry, remote monitoring via the VRM portal, and coordinated charging across multiple devices on the same CAN bus network. This makes the unit well suited to installations where a MultiPlus or Quattro inverter-charger is also present and charge source coordination is required.\u003c\/p\u003e\n\n\u003cp\u003eBluetooth is built in as standard. Using the VictronConnect app on iOS or Android, an installer can configure charge profiles, set absorption and float voltages, view live power data and update firmware without needing a separate dongle or laptop connection. The programmable relay adds flexibility for load shedding or generator start automation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: SCC125070521\u003c\/li\u003e\n  \u003cli\u003eMaximum PV open-circuit voltage: 250V\u003c\/li\u003e\n  \u003cli\u003eMaximum charge current: 70A\u003c\/li\u003e\n  \u003cli\u003ePV input connector: MC4 (integrated)\u003c\/li\u003e\n  \u003cli\u003eCommunication: VE.Can, Bluetooth (built-in)\u003c\/li\u003e\n  \u003cli\u003eWeight: 3.2 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076051909\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge off-grid residential and rural systems with 48V battery banks.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations requiring high PV input voltage tolerance.\u003c\/li\u003e\n  \u003cli\u003eCommercial and agricultural off-grid systems integrated into a Victron GX network.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and vehicle conversions with substantial solar array capacity.\u003c\/li\u003e\n  \u003cli\u003eHybrid systems alongside Victron MultiPlus or Quattro inverter-chargers using VE.Can coordination.\u003c\/li\u003e\n  \u003cli\u003eGround-mount solar arrays where long string runs benefit from higher input voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron SmartSolar MPPT 250\/70-MC4 VE.Can charge controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis controller operates at up to 250V DC on the PV input. Installation must be carried out by a qualified electrician or MCS-accredited installer familiar with high-voltage DC solar systems. Ensure PV string open-circuit voltage does not exceed 250V under any temperature conditions. Battery voltage is auto-detected on first power-up; verify the detected voltage before connecting the full load. VE.Can termination resistors must be correctly fitted at both ends of the CAN bus network. Refer to Victron's wiring guidelines for correct fusing and cable sizing on both the PV and battery connections.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":59863724163406,"sku":"SCC125070521","price":375.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/VoltaconSolar_-_SCC125070521_-_SmartSolar_MPPT_250-70-MC4_VE.Can.webp?v=1781183765","url":"https:\/\/voltaconsolar.com\/products\/victron-smartsolar-mppt-250-70-mc4-ve-can","provider":"VoltaconSolar","version":"1.0","type":"link"}