{"product_id":"voltasol-hybrid-10kw-three-phase-inverter-48v-g100","title":"G100 Compliant Hybrid 10kW Three Phase Solar Inverter HSI10000 48Vdc","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVoltasol 10kW Three-Phase Hybrid Solar Inverter | G100 | 48V | Pylontech BMS\u003c\/h1\u003e\n\u003cp\u003eThe Voltasol HSI10000 G100-compliant 10kW three-phase hybrid solar inverter for on-grid and off-grid operation with battery energy storage. 48V DC battery input, BMS compatible with Pylontech lithium batteries, Modbus card pre-installed, and support for parallel operation. Manufactured and supported by Voltacon.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10kW three-phase output: on-grid, off-grid, and grid-tie with backup\u003c\/li\u003e\n\u003cli\u003eG100 compliant for UK grid connection\u003c\/li\u003e\n\u003cli\u003e48V DC battery input: BMS compatible with Pylontech lithium-ion batteries\u003c\/li\u003e\n\u003cli\u003eAlso compatible with GEL and AGM lead-acid batteries\u003c\/li\u003e\n\u003cli\u003eModbus card pre-installed\u003c\/li\u003e\n\u003cli\u003eProgrammable supply priority: PV, Battery, or Grid\u003c\/li\u003e\n\u003cli\u003eUser-adjustable battery charging current up to 200A\u003c\/li\u003e\n\u003cli\u003eBuilt-in timer for programmable on\/off scheduling\u003c\/li\u003e\n\u003cli\u003eMultiple communications: USB, RS-232, Modbus, SNMP\u003c\/li\u003e\n\u003cli\u003eReal-time monitoring software included\u003c\/li\u003e\n\u003cli\u003eWarranty: 1 year standard, extendable to 3 or 5 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Voltasol 10kW G100 three-phase hybrid inverter is the G100-compliant version of the HSI10000 platform. G100 compliance ensures the inverter meets the UK grid connection standard for export limiting and demand response, making it the correct choice for UK grid-connected installations where G100 is specified by the DNO.\u003c\/p\u003e\n\u003cp\u003eThe inverter manages solar generation, battery charging and discharging, and grid import and export in a single unit. When solar output exceeds demand, surplus energy charges the battery bank. When demand exceeds solar output, the battery supplies the shortfall before drawing from the grid. During a grid failure, the inverter switches to off-grid mode to maintain supply from the battery and solar array.\u003c\/p\u003e\n\u003cp\u003eThe Modbus card is pre-installed, enabling integration with building energy management systems and third-party monitoring platforms including Solar Assistant.\u003c\/p\u003e\n\u003cp\u003eFor 0% VAT supply and installation enquiries, please contact us.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:2px solid #f87c24;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color:#f87c24; color:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px; font-weight:bold;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"padding:10px; font-weight:bold;\"\u003eValue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e\u003cstrong\u003eRated Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e10000W (10kW) three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e\u003cstrong\u003eGrid Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eG100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e\u003cstrong\u003eBattery Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e\u003cstrong\u003eMax Charge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e\u003cstrong\u003eBattery Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003ePylontech lithium (BMS), GEL, AGM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e\u003cstrong\u003eOperating Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eGrid-tie, off-grid, grid-tie with backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eUSB, RS-232, Modbus (pre-installed), SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e1 year standard (extendable to 3 or 5 years)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e90914004-G100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial and large residential three-phase hybrid solar and battery systems\u003c\/li\u003e\n\u003cli\u003eUK grid-connected installations requiring G100 compliance\u003c\/li\u003e\n\u003cli\u003eOn-grid with battery backup for resilience against power outages\u003c\/li\u003e\n\u003cli\u003eOff-grid three-phase commercial and agricultural installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation and Safety Notes\u003c\/h3\u003e\n\u003cp\u003eMust be designed and installed by a qualified electrician or MCS-accredited solar installer. Three-phase grid connection requires G99 application and DNO approval. Battery systems must comply with BS EN 62619 and local building regulations. Correct cable sizing, fusing, isolators, surge protection, and earthing are essential. Do not attempt DIY installation of three-phase hybrid inverter and battery systems.\u003c\/p\u003e","brand":"Voltacon","offers":[{"title":"Default Title","offer_id":47413202813262,"sku":"90914004-G100","price":3034.5,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0796\/3698\/8238\/files\/g100-compliant-hybrid-10kw-three-phase-solar-inverter-hsi10000-48vdc-471641.jpg?v=1747928549","url":"https:\/\/voltaconsolar.com\/products\/voltasol-hybrid-10kw-three-phase-inverter-48v-g100","provider":"VoltaconSolar","version":"1.0","type":"link"}