NH Fuse Switch Disconnectors
Functions
NH fuse switch disconnectors are used on low voltage electrical systems that require high protection against shortcircuit while securing on load circuit disconnection and isolation. We can find application on switchboard, distribution systems, OEM, etc.
General characteristics
▪ Four sizes available from 00 to 3 (up to 630A).
▪ Range uniformity and modularity.
▪ Size 00 and 1 offer single pole, double pole, triple pole and quadruple pole models.
▪ Mounting options. Size 000 DIN rail or base mounting. Other sizes base mounting or busbar mounting.
▪ Installation flexibility vertical or horizontal. Sizes 00,1 and 2.
▪ Self extinguishing halogen free materials.
Product construction Base: Manufactured of halogen free glass reinforced self-extinguishing material with high thermal stability characteristics. Copper contacts offer galvanic surface coating. Contact springs made of stainless steel. Symmetrical switch suitable for bottom / top cable terminal connections Cover: The switch operating cover is made of halogen free glass reinforced self extinguishing material. Supplied with large windows which enable to clearly check internal fuse characteristics and indicator status. Ergonomic handle for easy operation.
Technical specifications
Fuse |
NH 00 |
NH 1 |
NH 2 |
NH 3 |
||
Conventional free air thermal current with fuse links Ith |
160 A |
250 A |
400 A |
630 A |
||
Max. Allowed power dissipation of nh-fuse links Pn |
12 W |
23 W |
34 W |
48 W |
||
Conventional free air thermal current with solid links Ith |
200 A |
400 A |
630 A |
780 A |
||
Max. Allowed power dissipation of solid links Pn |
1.2 W |
2.6 W |
9 W |
17,5 W |
||
Utilization category |
AC 21 B |
690 V |
125 A |
200 A |
315 A |
500 A |
AC 21 B |
400 V |
|
|
|
|
|
DC 21 B1) |
440 V |
|
|
400 A |
|
|
AC 23 B |
400 V |
160 A |
250 A |
400 A |
630 A |
|
AC 22 B |
500 V |
160 A |
250 A |
400 A |
630 A |
|
DC 22 B |
220 V |
160 A |
250 A |
|
|
|
Rated operational voltage Ue |
690 V |
690 V |
690 V |
690 V |
||
Rated insulation voltage Ui |
1000 V |
1000 V |
1000 V |
1000 V |
||
Rated impulse withstand voltage Uimp |
8 kV |
12 kV |
12 kV |
12 kV |
||
Rated frequency |
50–60 Hz |
50–60 Hz |
50–60 Hz |
50-60 Hz |
||
Degree of protection |
IP20 |
IP20 |
IP20 |
IP20 |
||
Pollution degree |
3 |
3 |
3 |
3 |
||
Rated duty |
uninterrupted duty |
uninterrupted duty |
uninterrupted duty |
uninterrupted duty |
||
Rated short-circuit making capacity with solid links Icm |
6.2 kAsw |
8.2 kAsw |
10.6 kAsw |
18,6 kAsw |
||
Rated short-circuit making capacity with fuse links |
400 V AC |
80 kA / le = 160 A |
80 kA / le = 200 A |
80 kA / le = 400 A |
80 kA / le = 630 A |
|
500 V AC |
80 kA le = 160 A |
80 kA le = 200 A |
80 kA le = 400 A |
80 kA le = 630 A |
||
690 V AC |
50 kA le = 125 A |
80 kA le = 200 A |
80 kA le = 315 A |
50 kA le = 500 A |
||
Rated short-time withstand current with solid links Icw |
4 kA / 1 s |
8 kA / 1 s |
13 kA / 1 s |
18 kA / 1 s |
||
Power dissipation ith without NH-Fuse links |
2.3 W |
3.5 W |
20 W |
40 W |
||
Power dissipation ith without solid links |
3.3 W |
8 W |
50 W |
150 W |
||
Cable terminal connections |
M8 Screw |
M10 Screw |
M10 Screw |
M12 Screw |
||
Bus bar |
Type / Width |
60mm / 5-10mm |
40-60mm / 5-10mm |
40-60mm / 5-10mm |
- |