Solar cable 35mm² in black. Double Insulation. Price per meter
Solar cable HIKRA-Plus. Insulation colour black. HIKRA PLUS EN50618 35mm², black, outer-Ø 11,8 mm (PU 800m) H1Z2Z2-K, EN 50618:2014, TÜV R 60108819
In case you require different dimensions for the cable, add to basket multiple till the desired length is achieved
Solar cable HIKRA-Plus. Insulation colour black. HIKRA PLUS EN50618 35mm², black, outer-Ø 11,8 mm (PU 800m) H1Z2Z2-K, EN 50618:2014, TÜV R 60108819
Construction |
|
Strand construction |
Tin-plated copper strand (electrolytic copper), fine wire acc. IEC 60228 Class 5 |
Insulation |
Cross-linked Polyolefin; Shore hardness D 32; Minimum wall thickness acc. EN 50618 table 1 |
Outer Sheath |
Cross-linked special compound XLPO; Shore hardness D 36; Minimum wall thickness acc. EN 50618 table 1 |
Colour |
Sheath: black; Insulation: clear – naturally colored |
Marking |
HIKRA PLUS EN 50618 H1Z2Z2-K 25mm² R 60108819 |
Technical characteristics |
|
Nominal voltage [U0/U] |
1,5kV DC and 1,0/1,0kV AC |
Maximum operating voltage |
1,8kV DC (Internal examination 2,0kV DC) |
Voltage test on complete cable |
6,5kV AC / 15kV DC (5 minutes water bath, 20±5°C) |
Current carrying capacity |
See document „Current rating – HIKRA® Solar Cable“ November 2013 |
Max. resistance of conductor |
EN 50395 Clause 5 |
Short-circuit temperature |
250° C/5s |
Cross-section mm² |
Conductor construction n x max-Ø (mm) |
Max. resistance of Conductor (Ω/km) |
Cable OD (+/- 0,2 mm) |
Copper kg/km |
Weight kg/km |
1 x 35.0 |
280 x 0.41 |
0.565 |
11.8 |
336.0 |
370.0 |