Clearance / Ex-Display Units - Click here 
Home Owners, Did You Know You Can Buy a Complete Solar PV System and Pay 0% VAT?
Contact Us For Details on 0% VAT
  • Global Delivery Available
  • Solar Experts Since 2002
  • 5 Year Extended Warranty

EasySolar-II GX 48/3000/35-32 MPPT 250/70 GX - Inverter Charger 3kW

In stock
SKU
PMP482307010
Rating:
0% of 100
All-in-one solar power solution. The EasySolar-II GX combines a MPPT Solar Charge Controller, an inverter/charger and control hub in one enclosure.
£1,950.00 Incl VAT.
<
>
Accepted Payment Methods
Victron Inverters

Easy Solar Inverter and Solar Battery Charger - Combined Unit 3kW - GX Version

All-in-one solar power solution. The EasySolar-II GX combines a MPPT Solar Charge Controller, an inverter/charger and control hub in one enclosure.

The product is easy to install, with a minimum of wiring.

Prouct Code:PMP482307010
Victron Energy EasySolar-II 48/3000/35-32

Features

The all-in-one solar power solution

The Victron EasySolar-II GX integrates the following elements:

  • A MultiPlus-II inverter/charger
  • A SmartSolar MPPT -Tr solar charge controller
  • A GX device with a 2 x 16 character display

These elements come prewired together inside a single unit. This greatly simplifies most installations, saving time and money.

Display and wifi

The display reads battery, inverter and solar charge controller parameters. The same parameters can be accessed with a smartphone or other wifi enabled device. In addition, wifi can be used to set up the system and to change settings.

Solar charge controller

The DC output of the SmartSolar MPPT is parallel wired with the DC connection of the MultiPlus-II inverter/charger. The on/off mechanism of the MultiPlus-II also controls the SmartSolar MPPT.

GX device

The integrated GX device includes:

  • A VE.Can interface. This can be used to connect to Victron VE.Can devices (e.g. VE.Can MPPTs), or the port can be reconfigured via the Remote Console for use with a compatible CAN-bus Li-ion Battery
  • A USB port
  • A Ethernet port
  • A VE.Direct port The GX device controls the MultiPlus-II and the SmartSolar MPPT with respectively a VE.Bus and a VE.Direct connection.

EasySolar-II GX

EasySolar-II 48/3000/35-32 MPPT 250/70 GX

INVERTER/CHARGER

PowerControl & PowerAssist

Yes

Transfer switch

32A

Maximum AC input current

32A

Auxiliary output

Yes (32A)

INVERTER

Input voltage range

38 – 66V

Output

Output voltage: 230 VAC ± 2%

Frequency: 50 Hz ± 0,1% (1)

Cont. output power at 25°C (3)

3000VA / 2400W

Cont. output power at 40°C / 65°C

2200W / 1700W

Maximum apparent feed-in power

2500VA

Peak power

5500W

Maximum efficiency

95%

Zero load power

11W

Zero load power in AES mode

7 W

Zero load power in Search mode

2W

CHARGER

AC Input

Input voltage range: 187-265 VAC

Input frequency: 45 – 65 Hz

Charge voltage 'absorption'

57,6V

Charge voltage 'float'

55,2V

Storage mode

52,8V

Maximum battery charge current (4)

35A

Battery temperature sensor

Yes

Programmable relay (5)

Yes

Protection (2)

a - g

VE.Bus communication port

For parallel and three phase operation, remote monitoring and system integration

General purpose com. port

Yes, 2x

SOLAR CHARGE CONTROLLER

Model

SmartSolar MPPT 250/70-Tr

Maximum output current

70A

Maximum PV power

4000W

Maximum PV open circuit voltage

250V

Maximum efficiency

98%

Self-consumption

20mA

Charge voltage 'absorption', default

57,6V

Charge voltage 'float', default setting

55,2V

Protection (2)

a – e

GENERAL

Interfaces

VE.Can, USB, Ethernet, VE.Direct, wifi

Remote on-off

Yes

Operating temp. range

-40 to +65°C (fan assisted cooling)

Humidity (non-condensing):

max 95%

ENCLOSURE

Material & Colour

aluminium (blue RAL 5012)

Protection category

IP21

Battery-connection

M8 bolts

PV connection

M6 bolts

230 V AC-connection

Screw terminals 13 mm2 (6 AWG)

Weight

26kg

Dimensions (hxwxd)

506 x 275 x 237 mm

STANDARDS

Safety EN-IEC 60335-1, EN-IEC 60335-2-29

EN-IEC 62109-1, EN-IEC 62109-2

EN 55014-1, EN 55014-2

Emission / Immunity EN-IEC 61000-3-2, EN-IEC 61000-3-3

IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

Anti-islanding See our website

1) Can be adjusted to 60 Hz

2) Protection key:

a) output short circuit

b)  overload

c)  battery voltage too high

d)  battery voltage too low

e) temperature too high

f) 230 VAC on inverter output

g)  input voltage ripple too high

3) Non-linear load, crest factor 3:1

4) At 25°C ambient

5) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function.

AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC

 

Write a review: